Danfoss RET2001B Room and Programmable Room Thermostats Installation Guide
- October 30, 2023
- Danfoss
Table of Contents
Danfoss RET2001B Room and Programmable Room Thermostats
Product Information
The RET2001B and TP5001B are room and programmable room thermostats
manufactured by Danfoss Climate Solutions. The product is designed for
continuous use and operates on 2 AA alkaline batteries. It has a volt-free
output and a switch rating of 3A (1)
at 250Vac. The thermostat has a load compensation control and an on/off
control, with ErP class IV and efficiency gain of 2%. The product construction
is in compliance with EN60730-2-9 and has a pollution degree rating of degree
2. The product dimensions are H86 x W86 x D28 and it has an IP30 installed
rating. The thermostat has a running and setting resolution accuracy of +/- 1
minute per month with the built-in timer.
Product Usage Instructions
- Download the user guide from heating.danfoss.com.
- Installation must be done by an authorized electrician.
- The room thermostat should be installed at approximately 1.5 meters above the floor and away from sunlight, draught, or other heat sources (e.g. TV’s), see fig. 1 on page 44.
- Loosen the lower retaining screw and carefully remove the backplate, see fig. 2 on page 44.
- Mount the backplate directly to the wall or on the wall box and wire according to application, see fig 3 on page 44 & fig 5 on page 45 according to application.
- Insert 2x AA Alkaline batteries to the front part, taking care to insert correctly as indicated.
- Locate hooks at the top of the front part into the top of the backplate and lower into position and tighten retaining screw.
- Refer to fig. 4 for dimensions and fig. 5 for wiring diagram on page 45.
Installation Steps
User Guide can be downloaded from: heating.danfoss.com.
- Installation must be done by an authorised electrician.
- The room thermostat should be installed at approx. 1.5 m above floor and where the effects of sunlight, draught or other heat sources (eg. TV’s) are avoided, see fig. 1 on page 44.
- First loosen lower retaining screw and carefully remove back plate, see fig. 2 on page 44. 4. Mount back plate direct to wall or on wall box and wire according to application, see fig 3 on page 44 & fig 5 on page 45 according to application. 5. Insert 2x AA Alkaline batteries to front part taking care to insert correctly as indicated.
- Locate hooks at top of front part into top of back plate and lower into position and tighten retaining screw.
Dimensions and Wiring
See fig. 4 for dimensions and fig. 5 for wiring diagram.
Error codes
Display | Description |
---|---|
E1 | Sensor Failure |
EE | EEPROM Failure |
Lo | Measured temperature below 0 °C |
Hi | Measure temperature above 50 °C |
E6 | Real Time Clock (RTC) failure |
Technical Specifications
Specifications | RET2001B / TP5001B |
---|---|
Operating | Product is designed for continuous use |
Operating Voltage | 2 .5–3 VDC |
(2 x AA alkaline batteries)
Output| Volt free
Setting temperature range| 5 °C to 35 °C
Operating temperature range| 0 °C to 40 °C
Battery life| 2 Years
Switch rating| 3A (1) at 250Vac
Switch type| 1x SPDT Type 1B
Terminals| 1 to 2 .5 mm2 wires
IP rating| IP30 (installed)
Load compensation control| Yes
On/off control| Yes
ErP class| Class IV, efficiency gain 2 %
Construction| EN60730-2-9
Pollution Degree Rating| Degree 2
Rated impulse voltage| 4 kV
Ball pressure test| 75 °C
Dimensions| H86 x W86 x D28
Software classification| A
Running and setting accuracy (for thermostats with build in timer)| Setting
resolution 1 minute . Accuracy
+/- 1 minute per month .
UK
Danfoss Ltd.
Capswood, Oxford Road, Denham, UB9 4LH, UK
Danfoss A/S
- Heating Segment
- heating.danfoss.co.uk
- +44 (0)330 808 6888
- E-mail: customerservice.uk@danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues,
brochures and other printed materiaL Danfoss reserves the right to alter its
products without notice. This also applies to products already on order
provided that such alterations can be made without subsequential changes being
necessary in specifications already agreed.
All trademarks in this material are property of the respective companies.
Danfoss and all Danfoss logotypes are trademarks of Danfoss A/5. All rights
reserved.
References
- Danfoss Climate Solutions for heating | Efficient solutions for superior comfort | Danfoss
- Danfoss Salg Danmark | Danfoss
- Danfoss Deutschland | Klima | Kälte | Heizung | Antriebe | Hydraulik | Danfoss
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>