Dimensions

Dimension

Instructions For Use

Application

In-ground luminaire with symmetrical narrow beam light distribution.
For installation in cut-outs in topsoil.
The luminaires can be driven over by vehicles with pneumatic tyres.
Please note :
Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.
For walk-through public areas, we recommend skid-blocking glass
– see accessories.

Product Description

Luminaire made of stainless steel
Steel grade no. 1.4301
Clear safety glass
Reflector surface made of pure aluminium
Optical silicone lens · BEGA Hybrid Optics®
Required recessed opening ø 300mm
Minimum material thickness 40mm
Fixing is achieved by using four wedge-shaped clamping elements 1,8m water- resistant connecting cable
07RN8-F 5G1@ with implemented water stopper and 1.2m PVC cable conduit
BEGA Ultimate Driver®
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI controllable
A basic isolation exists between power cable and control line
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 68 10 m
Dust-tight and water pressure tight
Maximum submersion depth 10 m
Not suitable for permanent operation under water
Pressure load 2,000 kg (~20 kN)
Impact strength IK10
Protection against mechanical impacts < 20 joule
Maximum surface temperature 30 °C
(measured according to EN 60598 of ta 15 °C)
Conformity mark
Safety mark
Weight: 7.7 kg
This product contains light sources of energy efficiency classes D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Installation

Luminaire housing must not be installed in heat-insulating material.
Open the floodlight: Undo counter sunk screws.
Lift stainless steel trim ring and glass with gasket.
Fixing of the luminaire is achieved by using four wedge-shaped clamping elements.
For this purpose a recess opening of ø 300mm with a minimum depth of 230mm is necessary.
The upper edge of the recess opening must be firm on a thickness of 40mm in order to accept the clamping forces of the luminaire.
The electrical connection must be carried out with matching protection class and safety class with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
We recommend to use a BEGA distribution box 70 730 or 71 053.
To protect the luminaire power supply cable against mechanical damage, push the included installation pipe over the cable.
Note correct configuration of the mains supply cable. Make mains supply connection at the brown (L), blue (N) and green-yellow lead ( ).
The connection of the control cables is achieved by means of the both leads marked with DALI.
In case these leads are not used the luminaire will be operated at full light output.
Place luminaire into the recess opening and fix it by tightening the screws (torx drive T25) evenly.
Make sure that luminaire housing is properly fixed in the recess opening.
Insert glass with gasket with stepped side turned upwards and the groove structure of the gasket turned downwards into the luminaire housing.
Please note that the four screw heads of the fixing system must be placed into the cut-outs of the gasket.
Place cover ring onto the glass step and firmly tighten the screws crosswise.
Torque = 5Nm.

Please note :
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Lamp
Module connected wattage 35.7 W
Luminaire connected wattage 38.4 W
Rated temperature ta=25 °C
Ambient temperature ta max=40 °C

84 561K27
Module designation LED-0785/827
Colour temperature 2700 K
Colour rendering index CRI >80
Module luminous flux 5760 lm
Luminaire luminous flux 3886 lm
Luminaire luminous efficiency 101,2 lm/W

84 561 R K27
Module designation LED-0785/827
Colour temperature 2700 K
Colour rendering index CRI >80
Module luminous flux 5760 lm
Luminaire luminous flux 3402 lm
Luminaire luminous efficiency 88,6 lm/W

84 561K3
Module designation LED-0785/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 6010 lm
Luminaire luminous flux 4055 lm
Luminaire luminous efficiency 105,6 lm/W

84 561 R K3
Module designation LED-0785/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 6010 lm
Luminaire luminous flux 3550 lm
Luminaire luminous efficiency 92,4 lm/W

84 561K4
Module designation LED-0785/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 6165 lm
Luminaire luminous flux 4160 lm
Luminaire luminous efficiency 108,3 lm/W

84 561 R K4
Module designation LED-0785/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 6165 lm
Luminaire luminous flux 3642 lm
Luminaire luminous efficiency 94,8 lm/W

Lighting technology
Half beam angle 21°

Cleaning · Maintenance

After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form.
When using stainless steel cleaners, please read the directions carefully.
Cleaning agents containing hydrochloric acid and chlorides should never be used.
We recommend cleaning the luminaires regularly.

Replacing the LED Module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the electrical installation.
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during relamping.
Clean dirt and deposits from key openings of screw head. Do not use a high pressure cleaner. Open the luminaire and clean.
Use only solvent-free cleaners.
The luminaire housing must be completely clean and absolutely dry.
Please follow the installation instructions for the LED module.
Check all screws and threads thoroughly and grease them.
Check the gasket and replace, if necessary.
A broken glass must be replaced.
Insert glass with gasket – with stepped side turned upward and the groove structure of the gasket turned downward – into the luminaire housing. Make sure that the glass is correctly positioned in the gasket bed.
Place trim ring onto glass step and tighten screws crosswise.
Torque = 5Nm.

Accessories

14000233R Skid-blocking glass BEGA skid-blocking glass with the highest rating R 13 according to DIN 51130 can be used without restriction for all public areas.
Abrasion resistance according to EN ISO 10545-7 Class 3

Distribution box for installation in soil
70 730 Distribution box with 7 cable entries
Connection terminals 5 x 4@
71 053 Distribution box with 10 cable entries
Connection terminals 6 x 16@

For the accessories a separate instructions for use can be provided upon request.

Spares

Spare glass skid blocking 14 000 233R
Spare glass 14 001 523
LED power supply unit DEV-0270/700
LED module 2700 K LED-0785/827
LED module 3000 K LED-0785/830
LED module 4000 K LED-0785/840
Reflector 76 001 613
Gasket glass 83 002 038

Customer Support