BEGA 84454 In Ground Luminaire
Dimension
Instructions For Use
Application
Recessed location luminaire for recessed mounting in compacted surfaces, paths
and open areas. Drive-over luminaire for vehicles with pneumatic tyres.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture
is exposed to a horizontal strain due to braking, acceleration and change of
direction.
For walk-through public areas, we recommend skid-blocking glass
– see accessories.
Product Description
Luminaires and installation housings made of
highly corrosion-resistant aluminium
BEGA Tricoat® coating technology
Ring made of glass fibre reinforced synthetic material
Cover ring made of stainless steel
Steel grade no. 1.4301
Safety glass, white
Recess housing with cable entries for cable conduit, max ø 20 mm
1,8m water-resistant connecting cable
07RN8-F 3G1@ with implemented water stopper and 1.2m PVC cable conduit
BEGA Ultimate Driver®
LED power supply unit 220-240 V 0/50-60 Hz
DC 176-264 V
Safety class I
Protection class IP 68 10 m
Dust-tight and water pressure tight
Maximum submersion depth 10 m
Pressure load 5,000 kg (~50 kN)
Impact strength IK10
Protection against mechanical impacts < 20 joule
Maximum surface temperature 20 °C (measured according to EN 60598 of ta 15 °C)
Safety mark
Conformity mark
Weight: 5.6 kg
This product contains light sources of energy efficiency classes C
Overvoltage Protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
We recommend fuse protection via a residual current circuit breaker to be
provided by the customer.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Notice Prior To Installation
A foundation must be provided to accommodate the luminaire’s max. pressure
load of 5,000 kg (~50 kN).
The luminaire stands in a highly robust cast aluminium recessed housing.
The pressure load is transferred to the foundation provided by the customer
through this housing. The foundation must be laid on firm substrate.
The installation housing must be set in concrete for stability. Drainage must
be provided in the foundation to allow surface water to drain from the
recessed housing.
The external coating of the recessed housing must not be damaged. It is
important to ensure that the floor covering installed later will be at a level
with or below the upper edge of the recessed housing to guarantee a proper
seal of the luminaire – see sketch (detail A).
Soil Conditions
The luminaire must not permanently have contact with aggressive media. Aggressive media may be washed out of the ground and corrode the luminaire housing. If the composition of the ground is unknown, a ground analysis should be performed before installation. Aggressive media can additionally compromise the luminaire from the surface, which is why excessive use of de-icing agents in the immediate vicinity of the luminaire should be avoided. External stray currents conducted by the luminaire into the ground cause corrosion damage. Suitable countermeasures should be put in place.
Installation
Dismantle luminaire from the recess housing.
For this purpose loosen screws at the stainless steel ring up to the stop.
Turn luminaire counter-clockwise up to the stop, lift screws and lift
luminaire out of the recess housing.
Position recess housing on the foundation (as mentioned above) and fix it with
enclosed or any other suitable fixing material.
A customer-provided connecting sleeve outside of the installation housing is
required to connect the luminaire to the power supply.
We recommend to use a BEGA distribution box 70 730 or 71 053.
Pass the protective cable conduit from the connecting sleeve into the
installation housing.
Pass the connection cable through the protective conduit and connect it
securely to the underground cable.
0.5 m of cable is provided in the installation housing so that the luminaire
may be removed.
If a connection underneath the luminaire is planned, the customer must ensure
that there is enough clearance. We recommend a DN 150 pipe and the 70730
distribution box for drainage. After installation, the distribution box must
be sealed.
Insert the luminaire housing into the recess housing, turn it clockwise min.
10° and align it.
Tighten screws firmly.
Torque = 6.5Nm.
Cleaning · Maintenance
After installation, the luminaire should first be cleaned. Building dust,
residues from contact adhesives, paint splashes and rust film must be
completely removed. Never use high pressure cleaners and cleaning implements
made of normal steel, steel brushes or steel wool because they cause
extraneous rust to form.
When using stainless steel cleaners, please read the directions carefully.
Cleaning agents containing hydrochloric acid and chlorides should never be
used.
We recommend cleaning the luminaires regularly
Lamp
Module connected wattage 3.9 W
Luminaire connected wattage 5 W
Rated temperature ta=25 °C
Ambient temperature ta max=50 °C
When installed in heat-insulating
material ta max=45 °C
84 454K27
Module designation LED-0794/827
Colour temperature 2700 K
Colour rendering index CRI >80
Module luminous flux 725 lm
Luminaire luminous flux 270 lm
Luminaire luminous efficiency 54 lm/W
84 454 R K27
Module designation LED-0794/827
Colour temperature 2700 K
Colour rendering index CRI >80
Module luminous flux 725 lm
84 454K3
Module designation LED-0794/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 750 lm
Luminaire luminous flux 279 lm
Luminaire luminous efficiency 55,8 lm/W
84 454 R K3
Module designation LED-0794/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 750 lm
Luminaire luminous flux 279 lm
Luminaire luminous efficiency 55,8 lm/W
84 454K4
Module designation LED-0794/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 770 lm
Luminaire luminous flux 286 lm
Luminaire luminous efficiency 57,2 lm/W
84 454 R K4
Module designation LED-0794/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 770 lm
Luminaire luminous flux 286 lm
Luminaire luminous efficiency 57,2 lm/W
Replacing the LED Module · Maintenance
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
We recommend replacing the built-in seals and desiccant bag if the luminaire
has to be opened for maintenance purposes.
Article numbers are listed in the Replacements section.
Disconnect the electrical installation.
Clean the key opening in the bolt head from dirt and other residue. Do not use
high pressure cleaners. Only use solvent-free cleaning agents for cleaning the
luminaire.
Dismantle luminaire from the recess housing.
For this purpose loosen screws at the stainless steel ring up to the stop.
Turn luminaire counter-clockwise up to the stop and lift screws. Lift the
luminaire from the installation housing and place it with the glass side down
onto a clean, level surface.
The flexible connecting cable with water stop must be checked for external
damage and must only be replaced with a BEGA connection cable with water stop.
Check gaskets and replace if necessary.
Loosen the hexagon nuts (SW 10) and lift off the luminaire housing. To
disassemble the glass and gasket, at first push down the synthetic ring
firmly. Remove the glass and the gaskets.
Replace LED module. Follow the installation instructions for the LED module.
Remove the 4 hexagon socket screws (wrench size 5) and lift off the top of the
housing to replace the power supply unit. Replace the LED power supply unit.
Screw down all parts of the housing evenly. Ensure the correct seating of the
housing gasket.
Place the glass gasket around the glass with the wider side of the seal facing
up as shown in the illustration. Insert the glass with the stepped side facing
up into the luminaire housing and press down hard. Make sure that the glass is
seated correctly inside the gasket bed.
Pull up the synthetic ring up to the stop. Place the cover ring onto the glass
step and the synthetic ring. Make sure that the two bore holes in the
synthetic ring and cover ring are correctly aligned.
Tighten the hexagon nuts evenly in crosswise fashion.
Torque = 6.5Nm.
Accessories
14001403R Skid-blocking glass in accordance with EN ISO 51130 R13
Surface abrasion in accordance with
EN ISO 10545-7: Category II
Anti-slip protection in accordance with DIN 51097 Class C
Distribution box for installation in soil
70 730 Distribution box with 7 cable entries
Connection terminals 5 x 4@
71 053 Distribution box with 10 cable entries
Connection terminals 6 x 16@
A separate instructions for use can be provided upon request.
Spares
Spare glass 14 001 403
Spare glass skid blocking 14 001 403 R
LED power supply unit DEV-0303/350
LED module 2700 K LED-0794/827
LED module 3000 K LED-0794/830
LED module 4000 K LED-0794/840
Gasket glass 83 001 900
Customer Support
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com