BEGA 51057.4 Indoor Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
18.22
Technical amendments reserved
51 057.4
Wall luminaire for indoor use
Instructions for use
Application
Wall luminaire · indoor luminaire with velvet white luminaire housing and
inside hue.
The light emits upwards and downwards.
Product description
Wall luminaire “STUDIO LINE”
Aluminium luminaire housing,
finish Colour velvet white
inside hue matt brass
Light-diffusing synthetic LED cover 2 elongated fixing holes
Width 4.5 mm · 90 x 38 mm spacing 1 cable entry for through-wiring for mains
cable
Connecting terminals 2.5@
Earth conductor terminal
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-275 V
DALI-controllable
Basic insulation is provided between the mains
and control cables
BEGA Thermal Control ®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
**** – Conformity mark
Weight: 1.4 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage| 24.6 W
Luminaire connected wattage| 28 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 25 °C
51 057.4 K3
Module designation| 2x LED-0986/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 3370 lm
Luminaire luminous flux| 642 lm
Luminaire luminous efficiency| 22,9 lm / W
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Undo the hexagon socket head screws (wrench size 2.5 mm) and lift luminaire
housing. Unplug the earth conductor connection (plug contact).
Pass the power connecting cable through the cable entry in the mounting plate.
Fasten the mounting plate with the supplied fastening material or other
suitable fastening material to the installation surface.
Note position of application of the mounting plate “arrow down”.
Establish the earth conductor connection on the earthing screw (1) of the
mounting plate.
Push silicone sleeves over the lines.
Make the electrical connection to the terminals.
Observe the correct configuration of the connecting cable. Connect the live
conductor to the brown wire ( ****) and the neutral conductor to the blue wire
(N).
The two connecting terminals marked DA, DA are provided for digital control
purposes.
If these terminals are not assigned, the luminaire will work with full light
output.
Make earth conductor connection between luminaire housing and mounting plate
(plug contact).
Place connecting terminals inside the luminaire housing.
Note position of application of the luminaire “arrow down”.
Install luminaire housing over mounting plate and tighten hexagon socket head
screws (wrench size 2.5 mm) evenly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module ·
Replacing the power supply unit
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supply.
Unscrew the hexagon socket screws (SW 2.5) underneath and lift off the
luminaire housing. Remove the wires on the luminaire side from the terminals
marked (L), (N), DA DA.
Disconnect the earth conductor connection with the mounting plate (plug
contact).
Insert hex wrench (SW 2–2.5) in the bore holes in the diffuser lenses. Release
the diffuser lenses from their magnetic holders by rotating them slightly and
carefully pull them out of the luminaire housing together with the hex wrench.
Unscrew the two nuts (M 2.5) with serrated washers in the connection
compartment of the luminaire housing, and remove the die-cast housing with LED
modules and power supply unit from the luminaire housing.
Remove the LED module. Install the replacement LED module. Please follow the
installation instructions for the LED module.
Replace defective LED power supply unit.
Install in reverse order.
Spares
LED power supply unit| DEV-0402/700i
LED module 3000 K| LED-0986/930
Diffuser disk| 75 004 705
BEGA Gantenbrink-Leuchten KG
· Postfach 31 60 · 58689 Menden
· info@bega.com
· www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>