Safety Precautions:

  • Installation and maintenance work should only be performed by qualified persons who are familiar with local codes and regulations and have experience with this type of appliance.
  • All field wiring must be installed in accordance with the national wiring regulations.
  • Before commencing wiring work, ensure that the rated voltage of the unit matches the voltage stated on the nameplate.
  • The appliance must be permanently connected to the electricity supply through a double pole switch with a contact separation of at least 3mm in all poles.
  • The unit must be grounded to prevent possible hazards due to insulation failure. The earth wire should be approximately 60mm longer than the safety wire to ensure that in the event of suspension system failure, the fan remains earthed to prevent electrocution.
  • Tighten the blade firmly using a screwdriver to avoid detachment during operation, which can cause serious injuries and property damage.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Confirm that the power supply has been switched off before installing or servicing the unit. Ensure that the blade is fully static before performing any maintenance work.
  • Stop using the ceiling fan immediately when any abnormality or failure occurs.
  • If unusual oscillating movement is observed, stop using the ceiling fan and contact the manufacturer, its service agent, or suitably qualified persons.
  • When installing, ensure that the fixing means for attachment to the ceiling (such as hooks or other devices) are fixed with sufficient strength to withstand 4 times the weight of the ceiling fan.
  • The mounting of the suspension system should be performed by the manufacturer, its service agent, or suitably qualified persons. The fan should be installed so that the blades are more than 2.5m above the floor.
  • The safety cord should not be longer than the earthing conductor. If the suspension system fails, the support of the fan must not rely on the earthing conductor. The earthing terminal in the fan assembly should effectively earth the body of the fan assembly in case any part of the suspension system falls off.
  • Ensure that the unit’s panel is closed after service or installation to prevent noisy operation.
  • Avoid contact with sharp edges and coil surfaces, as they can cause injury hazards.

Safety Precaution

WARNING
Installation and maintenance work shall only be performed by qualified persons, familiar with local codes and regulations, and experienced with this type of appliance. All field wiring must be installed in accordance with the national wiring regulation. Ensure that the rated voltage of the unit corresponds to that of the nameplate before commencing wiring work according to the wiring diagram. The appliance must be permanently connected to the electricity supply through a double pole switch having a contact separation of at least 3mm in all poles. The unit must be GROUNDED to prevent possible hazards due to insulation failure. The earth wire is approximately 60mm longer than the safety wire. This is to ensure at the event whereby the suspension system fails, the (L) and (N) wire will break leaving the fan to remain earthed to prevent electrocution.
Tighten the blade firmly using a screwdriver.
Blades that are detached from the unit during operation will cause serious injuries and property damage.
WARNING
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that the blade is fully static before doing any maintenance work.
STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.
CAUTION
Please take note of the following important points when installing. The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan.
CAUTION
The mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons. The fan is to be installed so that the blades are more than 2.5m above the floor. Safety cord should not be longer than the earthing conductor. Should failure of the suspension system occur, the supporting of the fan must not rely on the earthing conductor. The earthing terminal in the fan assembly should be such that should any part of the suspension system fall off, the body of the fan assembly shall effectively earthed. Ensure that the unit’s panel is closed after service or installation. Unsecured panels will cause the unit to operate noisily. Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places. Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF” position. If this is not done, the unit’s fans will start turning automatically when power resumes, posing a harzard to service personnel or the user. Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral oil, oil vapor or oil steam exists, this may cause the plastic part to melt or deform as a result of excessive heat or chemical reaction. Avoid the ceiling fan unit from exposing to direct sunlight, this may cause degradation of plastic material as a result of excessive heat and UV radiation Ensure the color of the wires of the outdoor unit and the terminal markings are the same to the indoors respectively. Do not use joined and twisted wires for incoming power supply. Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan. The fan suspension system and blade screw tightening shall be examined yearly. Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons. Torque value for screws/bolts for securing the primary suspension system for the motor is 2Nm.

Parts & Accessories

ALPHA-ALKOVA-MILI-3B-33-33-Inch-DC-Motor-Ceiling-Fan-with-3-Blades-FIG-1
\(1\)ALPHA-ALKOVA-
MILI-3B-33-33-Inch-DC-Motor-Ceiling-Fan-with-3-Blades-FIG-1
\(2\)

Installation Instruction

  • a. Route all the wires from the Motor through the Downrod.
  • b. Fix the Downrod to the Motor Assembly with Bolt, Washer, and Nut and tighten them firmly then insert the Clevis Pin
    • IMPORTANT: CLEVIS PIN MUST BE INSERTED TO PREVENT THE NUT FROM LOOSENING.
  • Assemble the Canopy and Coupling Cover through the Downrod
  • Fix the Rubber Pulley Assembly to the Downrod with Bolt, Washer, and Nut, tighten them firmly, then insert the Clevis Pin.
    • IMPORTANT: CLEVIS PIN MUST BE INSERTED TO PREVENT THE NUT FROM LOOSENING.
  • a. Remove the Bolt, Washer, Nut, Clevis Pin, and Rubber Pulley from the downrod.
  • b. Place the Rubber Pulley onto the ceiling hook and fix back the Bolt, Washer, Nut, and Clevis Pin.
    • IMPORTANT: CLEVIS PIN MUST BE INSERTED TO PREVENT THE NUT FROM LOOSENING.
  • a. Remove the Safety Wire screw and spring washer from the Downrod.
    • b. Tie the Safety Wire across the hook as shown and firmly screw the Safety Wire onto the Downrod.ALPHA-ALKOVA-MILI-3B-33-33-Inch-DC-Motor-Ceiling-Fan-with-3-Blades-FIG-1 \(7\)
  • a. Connect the Connectors from Fan and Receiver.
  • b. Connect the wires from the receiver to House’s Supply wire.
  • c. Connect Earth Wire to House Supply Earth Terminal.
  • Install the Blades on the Motor with Blade Screw. Two pieces of Blade Screw for each Fan Blade.
    • IMPORTANT: ASSEMBLE THE BLADES ONLY AFTER THE CEILING FAN IS MOUNTED ON THE HOOK.
  • Install the decorative cover by twisting it in.
  • Below shows a complete installation diagram

Transmitter Learning Process

The receiver & transmitter is pre-programmed in the factory. If you wish to control 2 or more fans using 1 transmitter, the below steps are required. DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Turn on the power to the fan. Within 30 sec, press and hold the “LEARN” button for 3 sec. Once the receiver has detected the frequency, the transmitter with “Beep Beep” twice. The programming process is completed and the fan is ready to use

Transmitter Function

ALPHA-ALKOVA-MILI-3B-33-33-Inch-DC-Motor-Ceiling-
Fan-with-3-Blades-FIG-1 \(13\)

The transmitter & receiver is incorporated with the last memory function. This function stores your last setting in memory and the next time you turn on the fan, the fan will operate as the last setting.

The function of Forward & Reverse

The fan must be turned on and rotated.
Press and hold the Forward/Reverse button for 3 sec. The fan will slow down and then change direction (approx. 15 sec). When the fan is slowing down to change direction, the Fan Speed function is disabled until the direction has been changed.
Forward
The fan rotates anti-clockwise blowing the air downwards creating the wind chill effect. Suitable for hot weather conditions.

Reverse
The fan rotates clockwise drawing the air towards the ceiling and circulating the warm air downwards. This function works best at low speed. Suitable for air-conditioned conditions.

Transmitter Assembly

Install the Transmitter Holder to the wall with the 2 Screws provided.

Power Supply Connection

IMPORTANT: DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO THE REGULATOR OR DIMMER SWITCH.ALPHA-ALKOVA-MILI-3B-33-33-Inch-DC-Motor-Ceiling-
Fan-with-3-Blades-FIG-1 \(18\)

Circuit Diagram

ALPHA-ALKOVA-MILI-3B-33-33-Inch-DC-Motor-Ceiling-Fan-with-3-Blades-FIG-1
\(19\)

Maintenance

Due to the fan’s natural movement, connections may get loose after a period of usage. To ensure proper and safe usage, it is highly recommended to inspect and tighten all connections every 6 months.
Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures are as follows :

  1. Use only lukewarm water. Do not use detergent, corrosive or acidic solution.
  2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will scratch the surface.
  3. Do not bend the blades while cleaning. In the event that blades are bent or damaged, order a new set of blades from the service center or dealer shop.
  4. There is no need to oil the fan.

Technical Specifications

MODEL MILI-3B/33
No. of Blades 3
Fan Width 838mm (33”)
Motor RPM 90 – 236
Voltage 220-240V~ 50Hz
Motor Wattage 4W – 30W
Nett Weight 5.0kg

Information may be subject to 5% variation.ALPHA-ALKOVA-MILI-3B-33-33-Inch-
DC-Motor-Ceiling-Fan-with-3-Blades-FIG-1 \(20\)

CONTACT

Customer Service
If you need any technical assistance or a faulty report, please contact our customer service center at: ALPHA HOME APPLIANCES SDN. BHD. (390258-H) Head Office

Johor

  • 71, Jalan Molek 3/10,
  • Taman Molek, 81100 Johor Bahru.
  • Tel: 07-353 4833 / 4933
  • Fax: 07-355 4233

Pahang

  • A131, TK1, Jalan Wang Ah Jang,
  • Taman Liza, 25100 Kuantan, Pahang.
  • Tel: 09-516 522
  • Fax: 09-513 9226

Melaka

  • 19, 19-1 & 19-2, Jalan KSB 11,
  • Taman Kota Syahbandar, 75200 Melaka.
  • Tel: 06-292 6292 / 6293
  • Fax: 06-292 6296

Perak

  • 11, Jalan Tasek Timur 5,
  • Taman Tasek Indra, 31400 Ipoh, Perak.
  • Tel: 05-545 2282 / 547 2282
  • Fax: 05-547 6282

Penang

  • 28, Jalan Icon City, Icon City,
  • 14000 Bukit Mentajam, Penang.
  • Tel: 04-506 2366 / 2066 / 2566
  • Fax: 04-506 2966
  • Version: 2022 V1

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Alpha User Manuals

Related Manuals