AIPHONE JP-DVF-PR JP Series Video Door Station Installation Guide
- June 11, 2024
- AIPHONE
Table of Contents
JP-DVF-PR JP
Series Video Door Station
Installation Guide
JP-DVF-PR JP Series Video Door Station
The JP-DVF-PR is a JP Series video door station with a built-in AC-PROX-1G proximity card reader. The station connects directly to a JP-4MED master station using 2-conductor wire, and the card reader uses a standard Wiegand connection to connect to a compatible access control system. Features
- PTZ camera
- Stainless steel faceplate
- Built-in RFID card reader
Package Contents
Installation
For flush mounting, recess the supplied back box into the wall,
then attach the mounting bracket using the four provided bracket
screws.
Back Box Dimensions: 10-1/2″ H x 5-13/16″ W x 2-5/16″ D
JP-DVF-PR Dimensions: 11-11/16″ H x 7″ W x 2-1/16″ D
For surface mounting, use the SBX-IDVFRA surface mount box.
This box can mount to a standard single-gang box or to any flat
surface.
To insert the transparent nameplates, remove the vandalresistant front panel
from the flush mount back box. Peel off the protected seals from both sides of
the plate.
Write in the desired text, being sure to leave 1″ of white space on the right
side.
Insert the nameplate into the opening.
Wiring Diagram
Connect the reader to the access
control host according to the host’s to the host’s installation guide.
Wiegand Wiring
Conductor Red | Function |
---|---|
Black | 5 ~ 16V DC |
Green | Ground |
White | Data 0 |
Brown | Data 1 |
Orange | Red LED |
Yellow | Green LED |
Blue | Card Present |
Violet | Beeper |
Drain | fleaPower |
Shield Ground |
Specifications
Door Station
Camera Unit: | 1/4″ color CMOS |
---|---|
Scanning Line: | 525 lines |
Min. illumination: | 5 Lux |
Terminations: | Screw terminals |
Operating Temp: | -4°~140°F (-20°~60°C) |
Wiring Distance: | 330′ |
Dimensions: | 11-11/16″ H x 7″ W x 2-1/16″ D |
w/ SBX-IDVRA: | 11-11/16″ H x 7″ W x 3-5/16″ D |
Card Reader
Reader Type: | 125kHz Proximity Card Reader |
---|---|
Reader Model: | AC-PROX-1G |
Power Source: | 5 ~ 16V DC |
Current: | 30mA (average); 75mA (peak) |
Terminations: | Color-coded pre-wired pigtail |
Wiring Distance: | 500′ |
Operating Temp: | -31°~150°F (-35°~66°C) |
Operating Humidity: | 0% to 90% relative humidity non-condensing |
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation.
For proper regulatory compliance, the drain wire should be disconnected at the
power supply end of the cable.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
For more details about the features and information above, please contact
Technical Support.
Aiphone Corporation
www.aiphone.com
800-692-0200