BEGA 50591 Recessed Ceiling Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 50591 Recessed Ceiling Luminaire Instruction Manual
Instructions for use
Application
Recessed ceiling luminaire · indoor luminaire partially satin matt crystal
glass inside and aluminium alloy housing. For installation into ceilings with
a shallow depth in interior areas.
Product description
- Recessed ceiling luminaire »ACCENTA PURE«
- Die-cast aluminium housing
- Crystal glass, partially satin matt inside
- Reflector of anodised pure aluminium
- Metal ceiling frame ring, Colour white
- Recessed opening ø 68mm
- Required installation depth 60mm
- Fixing is achieved by using 2 adjustable wedge-shaped claws
- External LED power supply unit 220-240 V x 0/50-60 Hz
- Safety class II
- Safety mark
- Conformity mark
- Weight: 0.22 kg
- This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e.g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
Lamp
Module connected wattage 8.5 W
Luminaire connected wattage 10.4 W
Rated temperature ta=25 °C
Ambient temperature ta max=35 °C
50 591K27
Module designation LED-0923/927
Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 1155 lm
Luminaire luminous flux 549 lm
Luminaire luminous efficiency 52,8 lm/W
50 591K3
Module designation LED-0923/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 1200 lm
Luminaire luminous flux 570 lm
Luminaire luminous efficiency 54,8 lm/W
Installation
Luminaire housing must not be installed in heat-insulating material. The recessed opening will be covered by the frame of the luminaire. Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.
Installation into false ceilings
A recessed opening of ø 68 mm is necessary to accept the luminaire housing.
Free space depth min. 60 mm (see sketch). The claws catch the panel from the
reverse side. If minimum thickness of the panel is less than 3 mm it must be
reinforced from the reverse side. Maximum thickness of the panel must be no
more than 20 mm. The electrical connection must be made on site in the
appropriate safety class on the LED power supply unit connecting cable. A
distribution box must be used. Ensure the correct assignment of the connecting
cable. Establish the mains connection on the brown (L) and blue (N) wires.
Push external LED-power supply unit and luminaire housing into ceiling cut-
out. Luminaire housing and external LEDpower supply unit must not be installed
in heat-insulating material. Hand-tight screws of claw fasteners evenly. Lead
enclosed ceiling frame ring over the screw-neck of the glass and push it down
the gasket. Make sure that gasket is positioned correctly. Insert glass with
mounted reflector and frame ring by turning it clockwise into luminaire
housing.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective glass must be replaced.
Replacement of the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect from main supply.
- Unscrew glass with ceiling frame ring from luminaire housing by turning it counterclockwise.
- Please follow the installation instructions for the
- LED module.
- Check gasket. Screw in glass with ceiling frame\ ring by turning it clockwise beyond the stop.
- Defective glass must be replaced.
Spares
Spare glass 11 003 054 410RG
LED power supply unit DEV-0279/250
LED module 2700 K LED-0923/927
LED module 3000 K LED-0923/930
Trim ring 72 009 561 L
Reflector 76 001 209
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden ·
info@bega.com
www.bega.com