SIGNETIK GW-LRN8-ODC Long Range IoT Gateway User Guide
- June 5, 2024
- SIGNETIK
Table of Contents
- SIGNETIK GW-LRN8-ODC Long Range IoT Gateway
- Legal
- Product Summary
- Package Contents
- Product Specifications
- Dimensions
- Specifications
- Accessories (not included)
- Safety Information
- Software Configuration
- Regulatory and Environmental Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SIGNETIK GW-LRN8-ODC Long Range IoT Gateway
Legal
Copyright 2021, Signetik, LLC. All rights reserved.
Signetik, SigCell, SigSense, SigNet, SigFi, SigGate and SigLR are registered
trademarks of Signetik, LLC.
Disclaimers
Signetik provides all resources “as is” and with all faults, and disclaims all warranties, express and implied, including without limitation and implied warranties of merchantability, fitness for a particular purpose or non- infringement of third party intellectual property rights.
These resources are intended for skilled developers designing with Signetik products. You are solely responsible for
- selecting the appropriate Signetik products for your application,
- designing, validating, and testing your application, and
- ensuring your application meets applicable standards, and any other safety, security, or other requirements. These resources are subject to change without notice. Signetik grants you permission to use these resources only for the development of an application that uses the Signetik products described in the applicable resource. Other reproduction and display of these resources is prohibited. No license is granted to any other Signetik intellectual property right or to any third party intellectual property right. Signetik disclaims responsibility for, and you will fully indemnify Signetik and its representatives against, any claims, damages, costs, losses, and liabilities arising out of your use of these resources. Signetik’s products are provided subject to Signetik’s Terms of Sale (www.signetik.com/legal) or other applicable terms available either on www.signetik.com or provided in conjunction with such Signetik products. Signetik’s provision of these resources does not expand or otherwise alter Signetik’s applicable warranties or warranty disclaimers for Signetik products
Mailing Address
Signetik, 3833 South 14th St, Lincoln, NE 68502
Support
Users of Signetik products may receive assistance through the following channels:
- Symmetry Electronics – 1-866-506-8829
- Escalated to Signetik Technical Support
- Email: support@signetik.com
Customers should contact their distributor for support.
Warranty
Warranty information is available at www.signetik.com/legal
Label information
Physical Label
Model Number: GW – LRN8 – ODC Serial Number: 21D0005C
IMEI: 352656106378246
EUI: 0016c001ff186a4c
FCC ID: 2AOSN – GWLRN1ODC1
Contains FCC ID: 2ANPO00NRF9160
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Label examples
An example of a physical label is provided in a separate file.
Product Summary
Product Brief
SigGate Long Range IoT Gateway is an industrial-grade LoRa gateway supporting
scalable private and public LoRa networks. Built-in cellular networking
enables connecting LoRa sensors to the cloud even in remote locations.
Readily works with the LoRa ecosystem of devices and Application Servers, as
well as Signetik’s own suite of LoRa sensors and Network Servers.
Configuration is simple and hassle-free. Robust construction ensures reliable
operation even in harsh environments. Remote management tools and over-the-air
updates ensure easy operation and maintenance.
Product Variants
Product Name| Description|
---|---|---
GW-LRN8-ODC| 8-Channel Outdoor Gateway
GW-LRN4-ODC| 4-Channel Outdoor Gateway
Package Contents
- 1 – GW-LRNx-yDC
- 1 – 12V/1.6A Power supply
- 1 – Quick start guide
Product Specifications
Mechanical
Dimensions
Specifications
CPU| AM3352 – Armv7 Cortex-A8 800
MHz
| AM3352 – Armv7 Cortex-A8 800 MHz
---|---|---
OS| FreeBSD 12.1 or Ubuntu 18.04
DRAM| 512 MB DDR| 512 MB DDR
Storage| 8 GB eMMC| 8 GB eMMC
Ethernet| Auto-sensing 10/100 Mbps port (IP67 RJ45 connector)
Power| 12VDC input (7-14VDC) 1.6A, screw terminal connector through cable
gland, with included power cable and adapter
(100-240 VAC 50/60 Hz – 2A)
Lora Radio| IP67 RP-TNC connector
Cellular Radio| IP67 TNC connector
GPS Radio| Internal u.FL connector. Optional antenna required.
LED| Tri-color (RGB) indication of power, connectivity, and traffic.
Cellular
Mobile Network| Verizon & AT&T1
Cellular Standard| 4G-LTE Category M (NB-IoT fallback)
Frequency Band| Verizon
| B2 (1900)
| B4 (1700)
| B13(700)
| AT &T
| B2 (1900)
| B4 (1700)
| B12(700)
| B17(700)
Cellular Bandwidth| Up to 375 kbps downlink Up to 300 kbps uplink
Cellular Output Power| Up to 23 dBm
RX Sensitivity| -108 dBm
SIM Card| 4FF – Verizon Included – Contact Signetik for Activation
LoRa
LoRa Frequencies| 902-928 MHz (North America)
LoRa Channel Plan| US915
Channel Capacity| 8 channels| 4 channels
TX Power Output| 27 dBm Max
RX Sensitivity| -141 dBm at SF12 BW 125 kHz
RX Noise Figure| 2.5 dB
Max RF Input Level| +10 dBm
Physical Description
GW-LRN8-ODC | GW-LRN4-ODC | |
---|---|---|
Dimensions (L x W x H) | 175 x 130 x 45 mm | |
Weight | 1.85 lb | |
Chassis Type | ASA UL94HB | |
Ingress Protection | IP67 |
Interfaces
Power| Phoenix Contact 3-POS Screw Terminal Plug M12x1.5 Cable Gland
2-Wire 18 AWG
Wire Included with #6 Ring Terminals
LED| IP67 Light Pipe
Cellular| TNC Female
LoRa| RP-TNC Female
Ethernet| IP67 RJ45 Ethernet Jack
Venting| IP67 Gas/air/moisture vent
Environmental
Operating Temperature| -30C to 70C
Storage Temperature| -40C to 85C
Humidity| 20% to 90%
Certifications
EMC Compliance| FCC Part 15 Class B
Radio Compliance| FCC Part 22, 24, 27, 15C
Safety| Power Input UL60065 / UL 60950 EN 61000
Chassis
ASA UL94HB
MNO| Verizon / AT&T2
LED Indication
System Booting| Red
Radio Startup| Blue
Connected to Network| Orange/Yellow/Green/Purple
Cellular Signal Strength| Orange – Bad Yellow – Low Green – Good
Purple – Strong
LoRa Traffic| Blink Blue/Off
Ethernet Traffic| Blink Green/Off
Cellular Traffic| Blink Purple/Off
Connection Lost| Orange
Other
Warranty| 1-year / www.signetik.com/legal
Accessories (not included)
GW-LRN8-ODC | GW-LRN4-ODC |
---|
Essential
LoRa Antenna| WMO86916-TNM-5M
attached via Reverse polarity TNC connector
Cellular Antenna| LCO7270-TNM-RA
Recommended
Pole Mounting Bracket| Contact Signetik
Extra Power Cable| Contact Signetik
Power Cable Splicing| Contact Signetik
Battery Connectors| Contact Signetik
Safety Information
This device can be used in fixed and mobile installations. Fixed installations
are when devices is mounted on a physically immobile structure such as a pole
or building wall/ceiling. Mobile installations refer to mounting on objects
that move, such as on a vehicle.
In order to comply with FCC RF exposure requirements, this device must be
installed such that a minimum separation distance of 20 cm is maintained
between the antennas and all persons during normal operation.
Recommendations from other RF device manufacturers should be followed when
this product is installed in the vicinity of other RF devices.
Handling Precautions
Although the device is designed to protect against anti-static discharge from
handling, users should follow general anti-static precautions when handling
the device.
Hardware Setup
- Connect ETH Cable between your network and gateway device
- Connect LoRa Antenna
- Connect Cellular CAT-M antenna
- [Optional] connect GPS antenna
- Connect Power supply
Refer to mechanical drawing for location of connection ports.
Cellular SIM card A SIM card is built into the device. Activation of SIM card
should be coordinated with Signetik.
Contact Signetik to use a different SIM card than included with the device.
Software Configuration
LoRa configuration
Once the gateway is connected to the user’s network, a web browser can be used
to access gateway configuration page. The current configuration can be viewed.
Changes to configuration can be made from the webpage.
Note that a device reboot is required before some configuration changes can
take effect. A reboot can be initiated from the webpage after the
configuration details are setup.
The details of the private LoRa network server or LoRaWAN network server are
setup via this configuration page.
Cellular configuration
Cellular connections details are automatically handled in the software
preloaded on the gateway device. Cellular connection is established and
maintained by the gateway software as long as the SIM is active and has data
access to the cellular network.
Regulatory and Environmental Information
Information to the user
This equipment has been tested and found to comply with the rules for white space devices, pursuant to part 15 of the FCC rules. These rules are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the manufacturer, dealer, or an experienced radio technician for help.
FCC Declaration of Conformity
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user is advised that any equipment changes or modifications not expressly approved by the party responsible for compliance could void compliance with the FCC regulations and, therefore, the user’s authorization to operate the equipment.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>