BEGA 24 116 Ceiling and Wall Luminaire Instruction Manual

June 13, 2024
BEGA

BEGA logo 24 116
Technical amendments reserved
Ceiling and wall luminaire
Instruction Manual

24 116 Ceiling and Wall Luminaire

BEGA 24 116 Ceiling and Wall Luminaire - Symbol 1BEGA 24 116 Ceiling and Wall Luminaire Instructions for use

Application

Unshielded ceiling and wall luminaire with high protection class.
For a variety of interior and exterior lighting applications.
Lamp

Module connected wattage 22.4 W
Luminaire connected wattage 27 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C

24 116 K3

Module designation 4x LED-0894/830 + 2x LED-0900/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 4640 lm
Luminaire luminous flux 3824 lm
Luminaire luminous efficiency 141,6 lm / W

24 116 K4

Module designation 4x LED-0894/840 + 2x LED-0900/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 4770 lm
Luminaire luminous flux 3929 lm
Luminaire luminous efficiency 145,5 lm / W

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
White synthetic diffuser 2 elongated fixing holes
Width 7 mm · 600 mm spacing
Connection box with 2 cable entries for through-wiring of the mains supply cable ø 5-13 mm, max. 5×2,5◽
BEGA Ultimate Driver®
LED power supply unit 220-240 V x 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety mark
**** – Conformity mark
Weight: 6.0 kg
This product contains light sources of energy efficiency class(es) B

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Installation

Undo the hexagon socket head screw (wrench size 3 mm) in the luminaire base and remove covering cap.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.BEGA 24 116 Ceiling and Wall Luminaire - Figure
1Use the supplied connection box to make the electrical connection (see illustration).
Undo the hexagon socket screws and open the connection box.
Run the luminaire power supply cable through the PG 9 cable gland and the power connecting cable through the M25 cable gland and into the connection box. For throughwiring, the factory-fitted dummy plug must be removed.
Tighten the cable glands firmly.
Make the protective earth connection and the electrical connection.
Observe the correct configuration of the connecting cable. Make the mains connection to the brown (L), blue (N) and green-yellow wires ( ****).
The control cables are connected via the two DALI-labelled wires white-red (wh-rd) and white-black (wh-bl). If these wires are not assigned, the luminaire will work with full light output.
Close the connection box. Make sure the gasket is properly located.
Note the position of application of the luminaire top “arrow down”.
Place luminaire top onto theluminaire base and tighten screws evenly.

Replacement Power supply unit / LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Undo the hexagon socket head screw (wrench size 3) in the luminaire base and remove covering cap.
Loosen the three hexagon socket screws at the cover of connection compartment and lift off the cover of connection compartment.
Loosen connecting cable at the plug-in terminals.
Disassemble front-end head plate at the terminal side. For this purpose loosen hexagon head screw (wrench size 4) as far as it will go and remove head plate from the synthetic cover.
Pull out the LED module carrier out of the synthetic diffuser.
Replace power supply unit or LED module.
Please follow the installation instructions for the LED module.
Insert LED module carrier.
Make sure that the module carrier is seated in the guiding bolts of the opposite head plate.
Push head plate firmly on to the synthetic diffuser.
Make electrical connection at the plug-in terminals and assemble cover of connection compartment.
Place luminaire top onto the luminaire base and tighten screws evenly.

Cleaning · Maintenance

Clean dirt and debris from the luminaire regularly with a clean, soft, lint- free cloth that is kept damp throughout the cleaning.
If possible, please use water for this, adding a little commercial dishwashing detergent.
For lacquered surfaces we recommend the use of BEGA Lacquer Care Set 71 179.
Cleaning agents containing solvents and highpressure cleaners are unsuitable for cleaning and maintenance.

Spares

Spare glass 15 000 525 B1
LED power supply unit DEV-0293/700
LED module 3000 K LED-0894/830
LED module 4000 K LED-0894/840
LED module 3000 K LED-0900/830
LED module 4000 K LED-0900/840
Gasket glass 83 001 761

BEGA Gantenbrink-Leuchten KG · Postfach 31 60
· 58689 Menden
· info@bega.com