BEGA 77 055 In Ground Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
03.22
Technical amendments reserved
77 055
In-ground luminaire
IP 68
Instructions for use
Application
Recessed location luminaire for installation in gravel, lawns, flower beds, or
in compacted surfaces. Drive-over luminaire for vehicles with pneumatic tyres.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture
is exposed to a horizontal strain due to braking, acceleration and change of
direction.
For walk-through public areas, we recommend skid-blocking glass – see
accessories.
Product description
Luminaire made of stainless steel
Steel grade no. 1.4301
Safety glass, white
Silicone gasket
1,8 m water-resistant connecting cable
07RN8-F 3 G 1,5@ with implemented water stopper and 1.2 m PVC cable conduit
BEGA Ultimate Driver ®
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-264 V
BEGA Thermal Switch ®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 68 10 m
Dust-tight and water pressure tight
Maximum submersion depth 10 m
Not suitable for permanent operation under water
Pressure load 2,000 kg (~20 kN)
Impact strength IK10
Protection against mechanical
impacts < 20 joule
Maximum surface temperature 20 °C
(measured according to EN 60598 of ta 15 °C)
– Safety mark
**** – Conformity mark
Weight: 1.3 kg
This product contains light sources of energy efficiency classes C, D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
We recommend fuse protection via a residual current circuit breaker to be
provided by the customer.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
Installation
Luminaire for recessed mounting in gravel, lawns and flower beds.
The recessed depth must be arranged such that the trim ring is above ground
level.
When installed in compacted surfaces make sure that the housing is firmly
fixed and that the trim ring is not directly resting on the pavement or other
surfaces (Fig. A).
For this purpose installation housing 70 693 can be practical (Fig. B).
The electrical connection must be carried out with matching protection class
and safety class with suitable connection terminals (not included in the scope
of delivery) at the luminaire power supply cable.
We recommend to use a BEGA distribution box 70 730 or 71 053.
To protect the luminaire power supply cable against mechanical damage, push
the included installation pipe over the cable.
Tighten the screws in the trim ring evenly crosswise.
Torque = 3 Nm.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Lamp
Module connected wattage| 2 W
Luminaire connected wattage| 2.7 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 55 °C
When installed in heat-insulating material| ta max = 40 °C
77 055 K27
Module designation| LED-0305/827
Colour temperature| 2700 K
Colour rendering index| CRI > 80
Module luminous flux| 335 lm
Luminaire luminous flux| 96 lm
Luminaire luminous efficiency| 35,6 lm / W
77 055 K3
Module designation| LED-0305/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 345 lm
Luminaire luminous flux| 99 lm
Luminaire luminous efficiency| 36,7 lm / W
77 055 K4
Module designation| LED-0305/840
Colour temperature| 4000 K
Colour rendering index| CRI > 80
Module luminous flux| 350 lm
Luminaire luminous flux| 101 lm
Luminaire luminous efficiency| 37,4 lm / W
Cleaning · Maintenance
After installation, the luminaire should first be cleaned. Building dust,
residues from contact adhesives, paint splashes and rust film must be
completely removed. Never use high pressure cleaners and cleaning implements
made of normal steel, steel brushes or steel wool because they cause
extraneous rust to form.
When using stainless steel cleaners, please read the directions carefully.
Cleaning agents containing hydrochloric acid and chlorides should never be
used. We recommend cleaning the luminaires regularly.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the electrical installation.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
relamping.
Clean dirt and deposits from key openings of screw head. Do not use a high
pressure cleaner. Open the luminaire and clean.
Use only solvent-free cleaners.
The luminaire housing must be completely clean and absolutely dry.
Please follow the installation instructions for the LED module.
Check all screws and threads thoroughly and grease them.
Check the gasket and replace, if necessary. A broken glass must be replaced.
Insert glass with gasket – with stepped side turned upward and the groove
structure of the gasket turned downward – into the luminaire housing. Make
sure that the glass is correctly positioned in the gasket bed.
Place trim ring onto glass step and tighten screws crosswise.
Torque = 3 Nm.
Accessories
140224R Skid-blocking glass
BEGA skid-blocking glass with the highest rating R 13 according to DIN 51130
can be used without restriction for all public areas.
Abrasion resistance according to EN ISO 10545-7 Class 3
70 693 Installation housing
Distribution box for installation in soil 70 730 Distribution box with 7 cable
entries
Connection terminals 5 x 4@
71 053 Distribution box with 10 cable entries
Connection terminals 6 x 16@
For the accessories a separate instructions for use can be provided upon
request.
Spares|
---|---
Spare glass| 14 000 224
Spare glass skid blocking| 14 000 224 R
LED power supply unit| DEV-0292/350
LED module 2700 K| LED-0305/827
LED module 3000 K| LED-0305/830
LED module 4000 K| LED-0305/840
Gasket| 83 001 751
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
· info@bega.com
· www.bega.com
References