VEVOR GT-600 Micro Inverter Instruction Manual

June 1, 2024
VEVOR

VEVOR GT-600 Micro Inverter

VEVOR-GT-600-Micro-Inverter- product

Specifications

You are welcome to choose our micro grid-connected solar inverter products.

Specification Data GT-600 GT-800 GT-1200
Input Data (DC, PV) Number of Input MC4 Connector 2 sets 4 sets
Operation Voltage Range DC18V-50V
Maximum Input Current 12A*2 14A*2
16A*2
Output Data (AC) Single-Phase Grid Type AC230V AC230V
Maximum Output Power 600W 800W
Nominal Output Current 2.6A 3.5A
Nominal Output Voltage AC230V AC230V
Output Frequency Range 50Hz 50Hz
Power Factor 0.99%

Total Harmonic Distortion (THD)

Safety Precautions

  • Read the manual carefully before operating the micro inverter.
  • To reduce the risk of injury, ensure you follow the instructions provided.

Installation
Follow these steps for proper installation of the micro inverter:

  • Ensure the input connectors are securely connected to the solar panels.
  • Connect the output to the designated AC power system.
  • Check the voltage and current requirements to match the specifications.

Operation

To operate the micro inverter:

  • Ensure the DC input voltage falls within the specified range.
  • Monitor the output power and voltage to ensure optimal performance.
  • Check for any error indicators or warnings on the inverter display.

Frequently Asked Questions (FAQ)
Q: What should I do if there is a power outage?
A: In case of a power outage, the microinverter will automatically shut off to prevent any backflow of electricity. Once power is restored, the inverter will resume normal operation.

Technical Support and E-Warranty Certificate www.vevor.com/support

MICROINVERTER
MODEL:GT-600/GT-800/GT-1200

We continue to be committed to provide you tools with at competitive price.
“Save Half”, “Half Price” or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands.

MODEL:GT-600/GT-800/GT-1200VEVOR-GT-600-Micro-Inverter-
\(1\)

NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to contact us:
Technical Support and E-Warranty Certificate www.vevor.com/support

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

VEVOR-GT-600-Micro-Inverter- \(2\) WARNING: DANGER OF ELECTRICAL SHOCK
The product is used in combination with a permanent energy source (battery). Even if the equipment is switched off, a dangerous electrical voltage can occur at the input and/or output terminals. Always switch the AC power off and disconnect the battery before
performing maintenance.

The product contains no internal user-serviceable parts. Do not remove the front panel and do not put the product into operation unless all panels are fitted. All maintenance should be performed by qualified personnel. Never use the product at sites where gas or dust explosions could occur. Refer to the specifications provided by the manufacturer of the battery to ensure that the battery is suitable for use with this product. The battery manufacturer’s safety instructions should always be observed.
WARNING: do not lift heavy objects unassisted.

Installation

Read the installation instructions before commencing installation activities. This product is a safety class I device (supplied with a ground terminal for safety purposes). Its AC input and/or output terminals must be provided with uninterruptible grounding for safety purposes. An additional grounding point is located on the outside of the product. If it can be assumed that the grounding protection is damaged, the product should be taken out of operation and prevented from accidentally being put into operation again; contact qualified maintenance personnel.

Ensure that the connection cables are provided with fuses and circuit breakers. Never replace a protective device by a component of a different type. Refer to the manual for the correct part.

  • Check before switching the device on whether the available voltage source conforms to the configuration settings of the product as described in the manual.
  • Ensure that the equipment is used under the correct operating conditions. Never operate it in a wet or dusty environment.
  • Ensure that there is always sufficient free space around the product for ventilation, and that ventilation openings are not blocked.
  • Install the product in a heatproof environment. Ensure therefore that there are no chemicals, plastic parts, curtains or other textiles, etc.
    in the immediate vicinity of the equipment.

Transport and storage

  • On storage or transport of the product, ensure that the mains supply and battery leads are disconnected.
  • No liability can be accepted for damage in transit if the equipment is not transported in its original packaging.
  • Store the product in a dry environment; the storage temperature should range from –40°C to 65°C.
  • Refer to the battery manufacturer’s manual for information on transport, storage, charging, recharging and disposal of the battery.

SPECIFICATIONS

You are welcome to choose our micro grid-connected solar inverter products.

Specification data

| Model
---|---
GT-600| GT-800| GT-1200
Input Data (DC, PV)
Number of Input MC4 Connector| 2 sets| 4 sets
Operation Voltage Range| DC18V-50V
Maximum input Current| 12A2| 14A2| 16A*2
Output Data(AC)
Single-Phase Grid Type| AC230V| AC230V| AC110V or AC230V
Maximum Output Power| 600W| 800W| 1200W
Nominal Output Current| 2.6A| 3.5A| 10.9A or 5.2A
Nominal Output Voltage| AC230V| AC230V| AC110V or AC230V
Output Frequency Range| 50Hz| 50Hz| 60Hz or 50Hz
Power Factor| ≥0.99%
Total Harmonic Distortion| THD <5%
Maximum Units per Branch| @230VAC:4units| @230VAC:3units|

@110VAC:2units Or @230VAC:3units

Peak Efficiency| 95%
Nominal MPPT Efficiency| 99.5%
Night Power Consumption| ≤1W
Mechanical Data
Operating Ambient Temperature Range| -40℃ to +65℃
Storage Temperature Range| -40°C to +85C
Dimensions(WH D)| 305 186 44mm| 490 254 50mm
Waterproof Grade|

IP67

| IP65/IP67

(Please refer to the product nameplate information)

|

IP67

Communication| WIFI(Cloud monitoring)
Protection Functions| Isolated Island Protection,Voltage Protection Frequency Protection

Temperature Protection,Current Protection, etc.

INSTALLATION SCHEMATIC

Single-phase parallel assembly method of micro inverter

GT-600

VEVOR-GT-600-Micro-Inverter- \(2\)

  1. Single-Phase 230V grid Maximum 4 units 600W Micro inverters per branch.
  2.  The max DC input power of each inverter is 600W(the PV module max output power is 2x300W).
  3.  The VOC of PV modules should not be greater than the max DC input voltage of Micro inverters.

GT-800VEVOR-GT-600-Micro-Inverter- \(3\)

  1. Single-Phase 230V grid Maximum 3 units 800W Micro inverters per branch.
  2.  The max DC input power of each inverter is 800W(the PV module max output power is 2x400W).
  3. The VOC of PV modules should not be greater than the max DC input voltage of Micro inverters.

GT-1200

  1. @Single-Phase 110V grid Maximum 2 units or @Single-Phase 230V grid Maximum 3 units 1200W Micro inverters per branch.
  2. The max DC input power of each inverter is 1200W(the PV module max output power is 2x600W).
  3.  The VOC of PV modules should not be greater than the max DC input voltage of Micro inverters.

WIRING SCHEMATIC

Single phase connection method of micro inverter

GT-600/GT-800

VEVOR-GT-600-Micro-Inverter- \(3\)

Three phase connection method of micro inverter

GT-600/GT-800 VEVOR-GT-600-Micro-Inverter- \(4\)

MICRO INVERTER WIFI CLOUD MONITORING

  1. Precautions

    • Note that there is a risk of electric shock when connecting the micro-inverter!
      The micro-inverter heats up during operation! Protect yourself accordingly from burns!

    • Before configuring WiFi cloud monitoring,please correctly install the micro inverter and make it work normally.

    • As mart device(smartphone or tablet)with Bluetooth function and Android or is system and a wireless network device eg.wireless router that can provide WiFi and Internet service must be available.

    • To configure WLAN cloud monitoring,first switch on the Bluetooth function of the smart device.

    • Make sure that your smart device uses the same WiFi network as the micro inverter to be configured and that it can connect to wireless network devices and access the internet in the same location of the micro inverter.

    • Make sure that the distance between the wireless network device and the micro-inverter does not exceed 20 m and that there are no or few obstacles.

  2. Hardware Description
    VEVOR-GT-600-Micro-Inverter- \(5\)

  3. WIFI Status LED

    • The blue light flashes after always on = and the WiFi cloud monitoring module is waiting for configuration.
    • The blue light off after always on = the WiFi cloud monitoring module starts and enters the normal working state.
    • The blue light flashes = the network is not configured or the network cannot connect to the wireless network device, or the micro inverter has been deleted in the cloud.
    • No light = WiFi cloud monitoring is working normally.
  4.  Preparation Before Configuration And Use

    • Install the micro inverter correctly and make it work normally to generate power.
    • Download and install the or “Smart Life” app by searching for it in the corresponding Android or Apple app store.
    • Turn on the Bluetooth function of your smart device .
    • Check that your wireless network device(such as wireless router)is working properly and connected to the Internet .
    • Use your smart device ( or “Smart Life”App installed) at the installation location of micro inverter to connect to the wireless network device.If you can access the Internet normally, follow the instructions for configuration and usage on the next page.

VEVOR-GT-600-Micro-Inverter- \(8\)

Configuration Steps Of WIFI Cloud Monitoring.

VEVOR-GT-600-Micro-Inverter- \(9\) VEVOR-GT-600
-Micro-Inverter- \(10\)

 Usage Of WIFI Cloud Monitoring App.

Modify Device Name

  • Click the device to be modified in the device list on the home page to enter the device information details page (Figure 5).
  • VEVOR-GT-600-Micro-Inverter- \(6\)Click the button in the upper right to enter the device setting page (Figure 6), Continue to click the upper button to the page of name & position (Figure 7) click name item, then enter a new name and save it (Figure 8).

VEVOR-GT-600-Micro-Inverter- \(7\) Remove Device

  • Click the device to be deleted in the device list on the home page to enter the device information details page (Figure 5).
  • Click the button in the upper right to enter the device setting page (Figure 6).Click “Remove Device” button below (Figure 9), click the “Disconnect” button to remove the device or click the “Disconnect and wipe data”button to remove the device and clear all data saved by the device in the cloud at the same time.

VEVOR-GT-600-Micro-Inverter- \(8\) Share Device With Others

  • Click the device to be shared in the device list on the home page to enter the device information details page (Figure 5).
  • Click the button in the upper right to enter the device setting page (Figure 6).
  • Click the “Share Device” item to enter the device sharing page (Figure 10), click button to enter “Add Sharing”page (Figure 11) , and select best sharing way that you think it is most convenient to share the link of micro inverter.

VEVOR-GT-600-Micro-Inverter- \(9\)

INSTRUCTIONS FOR INSTALLATION WIRING

  1. The installation process of fixing the inverter to PV bracket with mountingscrews is as follows:VEVOR-GT-600-Micro-Inverter- \(13\)
  2. Connect the DC of PV to the inverter, and pay attention to distinguish between positive and negative, as shown below:VEVOR-GT-600-Micro-Inverter- \(14\)
  3. Open the waterproof cover on the AC output side of the micro inverter,and then connect it to the AC. As follows: VEVOR-GT-600-Micro-Inverter- \(15\)
  4. Repeat steps 1 to 3 to complete the installation of the microinverter.
  5. Connect multiple inverters through AC output cables.
  6. The AC main cable is connected to the power grid. VEVOR-GT-600-Micro-Inverter- \(16\)

SCHEMATIC DIAGRAM OF THE COMPLETION OF THE INSTALLATION

VEVOR-GT-600-Micro-Inverter- \(10\) VEVOR-GT-600
-Micro-Inverter- \(11\) VEVOR-GT-600-Micro-Inverter-
\(12\) VEVOR-GT-600-Micro-Inverter- \(1\)

GT-1200

Note :
When the inverter is purchased for the first time and connected to the mobile phone for monitoring, it is only necessary to switch on the mains AC, the blue light beside it flashes, and the inverter can be connected through WIFI or Bluetooth pairing. When the inverter can be controlled through the mobile phone, it is indicated that the connection is normal.

Questions & Answers

  1. WHAT TO DO when the Smart-App can’t find the micro inverter to be added?
    Check the following points:

    • Check if the WiFi status indicator of the micro inverter is in the “Blue Flashing” state.
    • Check if the Bluetooth function of your smart device is turned on.
    • Check if the signal of the wireless network is good.
      If all these is the case and the inverter is still not found, press the red reset button for more than 5 seconds to reset. After the WiFi indicator light flashes blue again, use “Smart Life ” App to reconfigure the network.
  2. WHAT TO DO if I have multiple micro inverters to configure?
    Install all micro inverters properly and make them work normally to generate power, and then operate according to the configuration and using steps. The App can search all inverters to be added at one time and configure them at one time.

  3. WHAT TO DO if the SSID of my WiFi network or the password is changed?
    Please reconfigure the inverter according to the configuration and using steps.

  4. WHAT TO DO if the WiFi status indicator of the inverter goes out, but the device displayed on the app is not online?
    This means that you can connect to the wireless network device, but you can’t connect to the cloud server. It means that your wireless network device can’t connect to the Internet. Make sure that your Internet is working properly.
    The installation site of the inverter is temporarily not equipped with a router and no WiFi signal?

  5. How does App connect the inverter and detect if the inverter is working properly?
    You can use an idle smartphone to open the WiFi sharing of mobile phone signal hotspot for connection, and reconfigure the network connection after installing the router.

  6.  There are multiple WiFi signals around. Can we connect different WiFi signals?
    No, the WiFi connected of the micro inverter and the smart phone must be consistent before the network can be configured.

  7. Can App configure the micro inverter in different places? Can I view data in different places?
    You can’t configure the micro inverter in different places, but you can view data in different places.The inverter uploads the latest status data to the cloud server every 3-5 minute.

  8. After checking that there is no problem, the App still cannot find the micro inverter.

    • Press and hold the inverter red button for more than 5 seconds to reset the inverter.
    • After the WiFi indicator flashes again, use App to reconfigure the network.
  9. WHAT TO DO if I want to monitor the same inverter on two or more smart devices?
    You can share the inverter with another phone using the share device feature.

  10. Will App data be saved?
    Yes, App data will be stored on cloud server. After the network is successfully configured, you can view the data at any time and place.

  11. The inverter cannot be connected to the app at night?
    At night, because the solar panel does not generate power, the micro inverter does not have any power input, so it will offline and it is impossible  to re- configure the network at night.

ACCESSORIES LIST

  1. Operating instructions *1
  2. Grid connected power cord *1
  3. 8mm diameter, 28mm long hex socket screw+flat washer+spring washer+nut *2
  4. .5mm diameter, 13mm long hex socket screw+nut 2(600W/800W) 4mm diameter, 8mm long hex socket screw 1(1200W)
  5. WiFi antenna *1

Address: Baoshanqu Shuangchenglu 803long 11hao 1602A-1609shi Shanghai
Imported to AUS: SIHAO PTY LTD.1 ROKEVA STREETEASTWOOD NSW 2122 Australia
Imported to USA: Sanven Technology Ltd. Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730

SHUNSHUN GmbH
Römeräcker 9 Z2021, 76351
Linkenheim-Hochstetten, Germany

UK REP

  • Pooledas Group Ltd
  • Unit 5 Albert Edward House, The
  • Pavilions Preston, United Kingdom

Technical Support and E-Warranty Certificate www.vevor.com/support

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VEVOR User Manuals

Related Manuals