PENTAIR Flotec FP5112 Portable Utility Transfer Pump User Manual

June 12, 2024
Pentair

PENTAIR Flotec FP5112 Portable Utility Transfer Pump User Manual
PENTAIR Flotec FP5112 Portable Utility Transfer Pump

SAFETY INSTRUCTIONS

**** This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal

words and be alert to the potential for personal injury: warns about hazards that will cause serious personal injury, death or major property damage if ignored.

CAUTION warns about hazards that can cause serious personal injury, death or major property damage if ignored. warns about hazards that will or can cause minor personal injury or property damage if ignored.

The word NOTICE indicates special instructions that are important but not related to hazards.

CALIFORNIA PROPOSITION 65 WARNING

WANING This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

GENERAL SAFETY

  1. Carefully read and follow all safety instructions in this manual and on the unit itself.
  2. Follow all applicable local and state codes and regulations.
  3. WARNING RISK OF EXPLOSION. HAZARDOUS PRESSURE. The pump body may explode if used as a booster pump unless a relief valve capable of passing the full pump flow at 75 PSI (517 kPa) is installed.
  4. WARNING RISK OF FIRE AND EXPLOSION. CAN CAUSE SEVERE INJURY, PROPERTY DAMAGE OR DEATH. To avoid risk of fire and explosion, pump only water with this pump. Do not use this pump in an atmosphere that might contain flammable fumes or vapors.
  5. CAUTION RISK OF BURNS. Never run the pump dry. To do so can damage internal parts, overheat pump (which can cause burns to people handling or servicing pump), and will void warranty.
  6. If water is trapped in the pump during operation it may turn to steam. Trapped steam can lead to an explosion and burns. Never run the pump with the outlet closed or obstructed.
  7. Do not touch an operating motor. Modern motors can operate at high temperatures. To avoid burns when servicing the pump, allow it to cool for 20 minutes after shut-down before handling.

ELECTRICAL SAFETY

  1. WARNING RISK OF ELECTRIC SHOCK. CAN SHOCK, BURN OR KILL. The pump is supplied with a 3-conductor grounding type cord. Connect only to a properly grounded,  GFCI protected outlet.
  2. Do not lift pump by the electrical cord.
  3. Unplug pump before servicing and disconnect power before working on pump, motor or tank.
  4. The pump is non-submersible. Keep the motor dry at all times. Do not wash the motor. Do not immerse. Protect the motor from wet weather.
  5. If using an extension cord, use only a UL approved indoor/ outdoor, 3-wire, grounding type cord. Do not allow any part of the cord or the receptacle ends to sit in water or in damp locations.
  6. Unplug the pump before servicing. To avoid fatal shocks, proceed as follows if the pump needs servicing.
  7. Disconnect the power to the pump outlet box before pulling the pump plug. After the plug is pulled, let the pump cool for 20 minutes before attempting to work on it.
  8. Take extreme care when changing fuses. To reduce the chance of fatal electrical shock, DO NOT stand in water or put your finger in the fuse socket.
  9. Ground electrical outlet box.

INSTALLATION & OPERATION

BEFORE INSTALLATION

  • Only pump clean water with this unit. This pump is not designed for applications involving salt water or brine! Using salt water or brine voids the warranty.
  • To avoid clogging the pump and damaging the shaft seal, do not pump water containing solids, foreign material, sand, silt, or abrasives. Always have the suction strainer installed when the pump is operating. Failure to use a strainer may cause the pump to fail and void the warranty.
  • Clean the strainer and flush out the pump after each use. Make sure all of the hose and pipe connections in the suction line are tight. An air leak in the suction line will prevent the pump from priming and reduce pump performance.
  • To prevent damage to pump materials, do not use pipe joint compounds on pump ports. Use only PTFE pipe thread sealant tape to seal the threads.
  • Tighten all of the piping joints to the pump hand tight +1½ turns only. Over-tightening may break the pump and will void the warranty.
  • Do not allow the pump or any system component to freeze. Freezing will void the warranty.
  • Periodically inspect the pump and the system components.

INSTALLATION: PRIMING THE PUMP

‘Priming’ refers to the pump expelling all air in the system and beginning to move water from its source out into the system. It does not refer only to pouring water into the pump (although pouring water in is usually the first step).

All suction connections must be airtight. Make sure the suction lift is not more than 25 feet (7.6M).

CAUTION RISK OF BURNS. NEVER run the pump dry. Running the pump without water may cause pump to overheat, damaging seal and possibly causing burns to persons handling the pump. Running pump without water can damage the impeller and may damage the seal, causing leaking or flooding, and will void the warranty. Fill the pump with water before starting it.

Follow the steps below:

  1. Remove the priming plug.
  2.  Make sure the suction and the discharge valves and any hoses on the discharge side of the pump are open.
  3. Fill the pump and suction pipe with water
  4. Replace the priming plug, using Teflon tape on the thread; tighten the plug. If a priming tee and plug have been provided for a long horizontal run, be sure to fill the suction pipe through this tee and replace the plug. (Use Teflon tape on the plug.)
  5. Start the pump; water should be produced in 10 minutes or less. The time will depend on the depth to water. If no water is produced within 10 minutes, stop the pump, release all the pressure, remove the priming plug, refill the ports and pipe and try again.

PUMPING FROM LAKES, STREAMS, AND PONDS

Locate the pump as near as possible (vertically) to the water source, to keep the suction lift (distance from the water to the pump) as low as possible. Place the pump on level support. Protect against excess moisture and flooding. Long pipe runs and many fittings increase friction and reduce flow. Use the smallest possible number of fittings and the shortest possible run for piping.

Support the weight of the pipe.

Be sure the water is clear of debris which can clog the pump, such as sand, dirt, or scale. Be sure the foot valve and the pipe are clean and in good condition; scale or dirt in the foot valve can cause the valve to leak. Valve leakage may cause the pump to lose its prime, which can result in pump failure.

PIPING

Both the suction and discharge ports are tapped for 1” MNPT threads. If using hoses, use a hose adapter. See Figure 1. Do not use a hose on the suction if pumping from lakes, streams or ponds. The hose will collapse and cause pump failure. Install a strainer with the foot valve on the end of the suction line. Inspect and clean the strainer frequently (Figure 1).
INSTALLATION & OPERATION

An air leak in the suction pipe may draw air in although no water leaks out. Make sure there are no air leaks or air pockets in the suction pipe.

BOOSTING CITY WATER PRESSURE

WARNING RISK OF EXPLOSION. HAZARDOUS PRESSURE.

  • When using a garden hose as a discharge line, do not run the pump with the hose outlet or the nozzle closed. The hose or the nozzle may burst from excessive pressure. See Figure 2.
    WATER PRESSURE
    Figure 2 – Do Not Run Pump With Outlet Shut Off

  • When using the pump as a high-pressure washer, use only reinforced high pressure hose or pipe for the discharge line.

  • When using a garden hose, install adapters on the pump suction and the discharge. The suction hose will require two female ends. Use a standard washing machine supply hose as a suction line (Figure 1).

LAWN SPRINKLING APPLICATION

Connect the suction hose to the faucet on the outside of the house (Figure 3) and to the pump suction. Use a standard garden hose for discharge. The pump can supply up to 3-4 sprinklers (depending on GPM output of the sprinklers).

ELECTRICAL

WARNING RISK OF ELECTRIC SHOCK. CAN SHOCK, BURN OR KILL

  • Plug the pump into a 115 Volt, 60 Cycle, Ground Fault Circuit Interrupter (GFCI) protected grounded outlet only.
  • The pump is equipped with a 3-wire, grounded, cord and plug. Do not modify or remove the plug.
  • Make sure the pump circuit meets the National Electrical Code (in USA) or the Canadian Electrical Code (in Canada).
  • To avoid dangerous electrical shock hazard, keep the cord dry at all times.
  • If using an extension cord, use the table below to size the extension cord.

LUBRICATION

  • The motor is lubricated at the factory for the life of the bearings.
  • The pump seal is water cooled and self lubricating.

PUMP SERVICE

WARNING RISK OF ELECTRIC SHOCK. CAN SHOCK, BURN OR KILL.

  • Unplug the pump before servicing it.
  • Do not handle the pump or attempt to work on the pump with wet hands or while standing on a wet or damp floor.
  • The motor has an auto-reset thermal overload protector. If the motor overheats, the overload will cut off the power to prevent damage and will reset after the motor cools. If the overload trips repeatedly, check the pump for the cause (low voltage, a clogged impeller, etc.).

PERFORMANCE / TROUBLESHOOTING

PERFORMANCE

| | GPM (LPM) AT TOTA| L FEET OF LIFT (m)| |
---|---|---|---|---|---
MODEL| 5′ (1.5 m)| 10′ (3 m)| 15′ (4.6 m)| 20′ (6.1 m)| 1 25′ (7.6 m)
FP5112| 6.1 (23)| 5.1 (19.3)| 4.2 (15.9)| 3.9 (14.8)| 3.0 (11.4)

TROUBLESHOOTING

SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Motor will not run. Fuse is blown or circuit breaker tripped. DISCONNECT

POWER. Replace fuse or reset circuit breaker.
Motor runs hot and overload kicks off or motor does not run and only hums.| Voltage is too low.| Check voltage being supplied to pump.
Motor runs but no water is delivered. Note : Stop pump. Check prime before looking for other causes. Unscrew priming plug and see if water is in priming hole.| Newly installed pump did not pick up a prime through:

  1. Improper priming,2.         Air leaks,
  2. Leaking foot valve,
  3. Pipe size too small. ****

**** Existing pump lost prime through:

  1. Air leaks,
  2. Water level below suction pipe inlet.

Either status:

  1. Impeller is plugged.
  2. Foot valve is stuck shut.
  3. Pipes are frozen.
  4. Foot valve and/or strainer are buried in sand or mud.

| New installation:

  1. Re-prime according to instructions.
  2. Check all connections on suction line, with soapy water or shaving cream.
  3. Replace foot valve.
  4. Re-pipe using pipe the same size as suction and discharge ports on pump. ****

Existing installation:

  1. Check all connections on suction line and shaft seal with soapy water.
  2. Lower suction line into water and re-prime. If the water level is more than 25’ (7.6M) below the pump, a deep well pump is needed. ****

Either status:

  1. Clean foot valve and strainer.
  2. Replace the foot valve.
  3. Thaw pipes.
  4. Raise foot valve and/or strainer above bottom of water source. Clean foot valve and strainer.

Pump does not delivery water to full capacity.|

  1. Water being pumped is lower than estimated.
  2. Corroded pipes or hoses
  3. Piping is too small in size
  4. Pump not being supplied with enough water.

|

  1. A deep well jet will be needed if your well is more than 25’ (7.6M) depth to water.
  2. Replace with plastic or new steel pipe
  3. Re-pipe using pipe the same size as suction and discharge ports on pump.
  4. Inlet pipe is too small

PARTS INDEX

PARTS INDEX

Key No. Part Description No. Used FP5112 1/2 HP
1 Pump Body 1 101P3410
2 O-Ring, Pipe Plug 1 111P0710
3A Priming Plug 1 102P1030
3B Drain Plug 1 102P1030
4 Hose Adapters 2 101P3460
5 O-Ring, Nozzle 1 111P0480
6 Diffuser Assembly 1 101P2840
7 Impeller 1 731S5700
8 Mechanical Seal 1 ZBR00010
9A Handle, R.H. 1 101P2080
9B Handle, L.H. 1 101P2090
9C Screws, Handle 5 121P1510
10 O-Ring, Pump Body 1 111P0700
11 Seal Plate 1 101P1290
12 Intermediate Support 1 731P0330
13 Water Slinger 1 102P0540
14 Motor 1 *
15 Gasket 1 111P1340
16 Capacitor Box (includes Cover, Gasket) 1 102P2830
17 Capacitor Box Screw 8 121P2060
18 Capacitor 1 171P5620

19

| Capacitor Cover Gasket| 1| 111P1350
20| Screws, Pump Body| 6| 121P1940

LIMITED WARRANTY

This Limited Warranty is effective July 11, 2019 and replaces all undated warranties and warranties dated before July 11, 2019.

Pentair Flotec* warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in material and workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within twelve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at Pentair Flotec’s option, subject to the terms and conditions set forth herein. Note that this limited warranty applies to manufacturing defects only and not to ordinary wear and tear. All mechanical devices need periodic parts and service to perform well. This limited warranty does not cover repair when normal use has exhausted the life of a part or the equipment.

The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility is based on purchase date of original product – not the date of replacement under warranty. The warranty is limited to repair or replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed per purchase). Purchaser pays all removal, installation, labor, shipping, and incidental charges.

Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet where it was purchased immediately after the discovery of any alleged defect. Pentair Flotec will subsequently take corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after the warranty expires. Warranty is not transferable and does not apply to products used in commercial/rental applications. For parts or troubleshooting assistance, DO NOT return product to your retail store – contact Pentair Flotec Customer Service at 1-800-365-6832.

SEWAGE PUMPS
DO NOT return a sewage pump (that has been installed) to your retail store. Sewage pumps that have seen service and been removed carry a contamination hazard with them.

If your sewage pump has failed:

  • Wear rubber gloves when handling the pump;
  • For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
  • Dispose of the pump according to local disposal ordinances. Contact Pentair Flotec Customer Service at 1-800-365-6832.

EXCEPTIONS TO THE TWELVE (12) MONTH LIMITED WARRANTY

PRODUCT WARRANTY PERIOD
Parts2O* (Parts & Accessories), FP0F360AC, FP0FDC 90 days
FP0S1775A, FP0S4100X, FPPSS3000, FPCC5030, FPCI3350, FPCI5050, FPDC30 2 Years
FPSC1725X, FPSE3601A, FPSC3350A, FPZT7300, FPZT7350, FPZT7450, FPZT7550 2

Years
FP7100/FP7400 Series Pressure Tanks, E3305TLT, E3375TLT, E5005TLTT, E50TLT, E50VLT, E75STVT, E75VLT, FPSE9000, FPSE9050| 5 Years

GENERAL TERMS AND CONDITIONS; LIMITATION OF REMEDIES

You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not apply to the following: (1) acts of God; (2) products which, in the sole judgment of Pentair Flotec, have been subject to negligence, abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4) atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.

This warranty sets forth the sole obligation of Pentair Flotec, and purchaser’s exclusive remedy for defective products.

PENTAIR FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how  long an implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

293 Wright Street
Delavan, WI 53115
Ph: 800.365.6832
Fx: 800-526-3757

All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.

©2023 Pentair. All Rights Reserved.

PENTAIR LOGO

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Pentair User Manuals

Related Manuals