BEGA 12292.2 LED Large Area Ceiling Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 12292.2 LED Large Area Ceiling Luminaire

BEGA-12292-2-LED-Large-Area-Ceiling-Luminaire-fig-1

Product Information

  • Safety: The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
  • Overvoltage Protection: The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients, it is recommended to use separate overvoltage protection components.
  • Lamp Module Connected Wattage: 52.6 W
  • Luminaire Connected Wattage: 60 W
  • Rated Temperature: 25°C to 55°C
  • Ambient Temperature: 25°C to 55°C
  • Lamp Module Designation: LED-0618/930 + LED-0619/930
  • Colour Temperature: 3000 K
  • Colour Rendering Index (CRI): >90
  • Module Luminous Flux: 8040 lm
  • Luminaire Luminous Flux: 5 962 lm
  • Luminaire Luminous Efficiency: 99.4 lm/W
  • Lamp Module Designation: LED-0618/940 + LED-0619/940
  • Colour Temperature: 4000 K
  • Colour Rendering Index (CRI): >90
  • Module Luminous Flux: 8640 lm
  • Luminaire Luminous Flux: 6406 lm
  • Luminaire Luminous Efficiency: 106.8 lm/W

Product Usage Instructions

  1. Unpack the luminaire.
  2. Detach the matt black trim strip unilaterally from each of the short sides of the luminaire beyond the corner of the profile.
  3. Take up the luminaire and slide it into the cleared profile grooves on both sides of the hangers for about 70 – 100 mm so that the luminaire terminals are within reach. Push the clamping pieces upwards by means of the bottom-side screws to ensure proper insertion.
  4. Make sure that the luminaire cable is not damaged during insertion
  5. Lead the luminaire cable through the enclosed membrane grommet and make LED connection to the terminals. Pay attention to correct polarity, black: Driver -, red: Driver +.
  6. Place the canopy on top of the luminaire housing.
  7. Make an earth connection (plug connection) between the canopy and mounting plate.
  8. Push the membrane grommet into the provided opening and attach the canopy onto the mounting plate using the magnets.
  9. Slide in the luminaire evenly until it reaches the mid position of the hangers. Push both bottom-side screws at the same time to secure the position of the luminaire.
  10. Fix the screws of the clamping pieces to further secure the position of the luminaire.
  11. Push in the matt black trim strip into the profile notches on both short sides of the luminaire. To conceal the groove, push the end section of the trim strips under the hangers.
  12. Push any excessive cable through the membrane grommet into the canopy.

DIMENSION

BEGA-12292-2-LED-Large-Area-Ceiling-Luminaire-fig-2

Application

Large-area ceiling luminaire · indoor luminaire with optical system aluminium housing, for glare-free lighting in the workplace.

Product description

  • Luminaire housing made of matt aluminium with all-round, matt black trim strip
  • Optical system as a layered structure of micro-structured and light-directing reflection levels Glare suppression according to
  • DIN EN 12464-1
  • 2 cable entries for through-wiring for mains cable up to ø 11 mm max. 5 x 1.5@ Connection terminal 2.5@
  • Earth conductor connection
  • 2-pole connecting terminal for digital control
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • During DC operation the LED power is reduced to 15 %
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • Safety class I
  • r – Safety mark
  • c  – Conformity mark
  • Weight: 11.0 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to  the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

PRODUCT SPECIFICATION

  • Lamp
    • Module connected wattag e 52.6 W
    • Luminaire connected wattage 60 W
    • Rated temperature ta = 25 °C
    • Ambient temperatur e ta max = 55 °C
  • 12 292.2 K3
    • Module designation LED-0618/930 + LED-0619/930
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 8040 lm
    • Luminaire luminous flux 5962 lm
    • Luminaire luminous efficiency 99,4 lm / W
  • 12 292.2 K4
    • Module designation LED-0618/940 + LED-0619/940
    • Colour temperature 4000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 8640 lm
    • Luminaire luminous flux 6406 lm
    • Luminaire luminous efficiency 106,8 lm / W

Installation

  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
    Please note:
    It is recommended to deploy 2 people to install this luminaire.

  • Unpack mounting plate with canopy.

  • Pull off canopy from mounting plate against the magnetic resistance.

  • Strip cable end approx. 80 mm.

  • Lead mains supply cable through the elongated hole of the mounting plate.

  • Fix mounting plate with enclosed or any other suitable fixing material onto the mounting surface.

  • Make earth connection and electrical connection to to the terminals of the power supply unit.

  • For digital control please use the connecting terminal DA, DA.

  • In case this terminal is not used the luminaire will be operated at full light output.

BEGA-12292-2-LED-Large-Area-Ceiling-Luminaire-fig-3

  • Unpack luminaire.
  • Detach the matt black trim strip unilaterally from each of the short sides of the luminaire beyond the corner of the profile.
  • Take up the luminaire and slide in the cleared profile grooves on both sides of the hangers for about 70 – 100 mm so that the luminaire terminals are within reach.
  • For that purpose it is necessary to push the clamping pieces upwards by means of the bottom-side screws, see sketch.
  • Make sure that the luminaire cable is not damaged during insertion.
  • Lead the luminaire cable through the enclosed membrane grommet and make LED-connection to the terminals.
  • Pay attention to correct polarity, black: “Driver -“, red: Driver +”.
  • Place canopy on top of the luminaire housing. Make earth connection (plug connection ) between canopy and mounting plate.
  • Push the membrane grommet into the provided opening and attach canopy onto the mounting plate by means of the magnets.

BEGA-12292-2-LED-Large-Area-Ceiling-Luminaire-fig-4

  • Slide in luminaire evenly until the mid position of the hangers. Make sure to push both bottom-side screws at the same time.
  • Secure position of luminaire by fixing the screws of the clamping pieces.
  • Push in the matt black trim strip into the profile notches on both of the short sides of the luminaire.
  • To conceal the groove push the end section of the trim strips under the hangers.
  • Push excessive cable through the membrane grommet into the canopy.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.
  • To clean the optical system of the luminaire an antistatic cleaner for synthetic materials is recommended.
  • Note care instructions accordingly.

Spares

  • Spare glass (layered structure) 15 000 438 .1M
  • LED power supply unit DEV -0214/1050
  • LED module 3000 K LED -0619/930
  • LED module 4000 K LED -0619/940
  • LED module 3000 K LED -0618/930
  • LED module 4000 K LED -0618/940

ABOUT COMPANY