AirGuard AG-20 Antibacterial Vaporizer User Manual
- June 6, 2024
- AirGuard
Table of Contents
AG-20 Antibacterial Vaporizer
USER MANUAL
Safety Information
Thank you for choosing Air Guard. Please read the following safety information carefully before operating the machine. This information includes important safeguards about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the machine.
- Keep this device dry.
- Always connect to a grounded circuit to avoid risk of electrocution.
- Before connecting the machine to power, always check the voltage indicate on the machine matches to your local AC voltage. Do not use the machine if AC power voltage does not match.
- Disconnect the machine from AC power before servicing and when not in use.
- If the supply cord is damaged, contact your local dealer for replacement.
- This product is for indoor use only! Do not expose to rain or moisture. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, immediately unplug the machine and contact your local dealer for advice.
- No user serviceable and modifiable parts inside. Never try to repair this product, an unauthorized technician may lead the machine to damage or malfunction.
- For adult use only. Children being supervised not to play with the machine. Never leave the machine running unattended.
- The machine is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
- Installed in a well ventilated area. Provide at least 50 cm space around the machine.
- Never add flammable liquid of any kind to the machine.
- Make sure there are no flammable materials close to the machine while operating.
- Only use Air Guard Antibacterial Solution. Other solution may lead to heater clog and malfunction.
- If the machine fails to work, unplug the machine and stop operation immediately. Contact your local dealer for advice.
- Before transporting the machine, make sure the fluid tank is completely drained.
- Air Guard Antibacterial Solution may present health risks if swallowed. Do not drink Air Guard solution. Store it securely. In case of eye contact or if solution is swallowed immediately look for medical advice.
Unpacking and Inspection
Immediately upon receiving the antibacterial vaporizer, carefully unpack the carton, check the content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retain the packing material for inspection.
What is included:
1 x AG-20 Antibacterial Vaporizer
1 x Battery
1 x Battery Charger
1 x Wireless Remote Control
1 x FLE-05 Antibacterial Solution
1 x User Manual
Product Dimensions
Product Overview
Setting Up
Step 1: Place the machine on a flat surface and in an area with at least
50 cm open space at each side of the machine.
Step 2: Fill the fluid tank with Air Guard fluid.
Always connect the machine to a protected circuit and ensure it is properly
grounded to avoid risk of electrocution.
Step3: Connect the battery base or power base to the fog machine. Turn on
the machine to start operation.
Battery and Chargers
When the LED indicator on the charger turns red, the battery is being charged.
When it turns green, the charging process is completed. A low power battery
requires approximately 3 hours to be fully charged. A fully charged battery
can run the machine for roughly 12 minutes.
Operation
Manual Mode
Put DIP switch 1 ~ 9 to OFF position for manual mode.
In the manual mode, fog output can be triggered by either keeping holding the
handle button or pressing once the button A on the wireless transmitter. To
stop fogging, release the handle button or press once the button B on the
wireless transmitter.
Timer Mode
Use the DIP switch located in front of machine to set the timer’s duration
(fogging) time. Duration time can be set from 15 to 240 seconds. Put DIP
switch to ON position for desired duration time.
Longer timer setting overwrites shorter timer setting. For example: When both
DIP switch 1 and 9 set to ON position, the duration time will be 240 seconds.
Timed fogging can be triggered by either pressing the handle button once or
pressing the button A on the wireless transmitter once. When the timed
fogging’s time is up, machine stops automatically.
To stop timed fogging immediately, press once handle button or press once the
button B on the wireless transmmiter.
Radio Wireless Remote System
Radio wireless remote control system consists of a transmitter with two buttons to activate and deactivate fogging. The wireless signal receiver (antenna) is attached to the rear panel of AG-20.
Press [A] button to emit fog and press [B] button to stop fogging.
In an open space, the maximum distance of the radio wireless remote is 50 meters. However, the operating distance depends on obstacle levels.
Pairing and Deleting a transmitter with receiver
Transmitters can be paired or deleted from the wireless signal receiver. Each
receiver can pair up to 5 transmitters. Follow the steps below to pair or
delete a transmitter from a receiver.
To Pair
Step 1: Put Dip switch 11 to ON position
Step 2: The red LED indicator on handle starts to blink. Press button A on the
transmitter once to pair it with the receiver.
Step 3: Once pairing is completed, LED indicator will be constant on for 3
seconds
Step 4: Put Dip switch 11 back to OFF position to start operation
To Delete
Step 1: Put the dip switch 10 to ON position
Step 2: The red LED indicator on handle starts to blink. Press button A on the
transmitter once to delete it from the receiver.
Step 3: The deleting process takes approximately 10 seconds
Step 4: Once deleted, the LED indicator will be on for 3 seconds
Step 5: Put the dip switch 10 back to the OFF position to start operation
Transmitter battery replacement
If the operating distance of the radio wireless remote becomes shorter, it is
possible the wireless transmitter’s battery power is getting low and requires
a replacement. In order to replace the battery, undo the three screws on the
back of transmitter to remove the case. Replace with the same type and
specification of battery which is 27A 12V.
Fluid
Use Air Guard Antibacterial Solution for AG-20. The machine is tested and calibrated with these authorized fluids to achieve the best performance. Warranty will be void, if any other type of liquid is used. Improper use of liquid may lead to machine failure and danger.
Service and Maint
- It is recommended to run the machine on a monthly basis in order to achieve best performance and output condition.
- Excessive dust, liquid and dirt built up will degrade performance and cause overheating.
- In an event of machine error, contact an authorized distributor/dealer for further technical supports and service.
Red LED Indicator on the handle
Machine’s Status | LED Indicator |
---|---|
Ready to fog | Constant on |
Producing fog | Slow flash every 0.7 second |
Low battery | Quick flash every 0.3 second |
Machine error | Qucik flash every 0.1 second |
Maintenance of Rechargeable lead-acid Battery
To give the rechargeable battery long lifespan and best performance, please follow below instructions:
- Please fully charge the battery upon receipt of the machine.
- Every 2-4 weeks, check and ensure the battery has sufficient power to work. At least charge the battery to full every 4-6 months.
- Before storage, please have the battery fully charged.
- Please store the fully charged battery and the machine in cool and dry area, avoid directly sunlight.
- Please charge the battery within 24 hours if the battery is going to run out of power.
- If you have any question on maintenance and usage, please contact your local dealer for advice.
Technical Specifications
– Input voltage
– Rated power
– Warm-up time
– Fluid consumption
– Fluid tank capacity
– Compatible fluid
– Ambient temp. range
– Control
– Dimension
– Weight| DC 12V (Battery) AC 100-240V, 50-60Hz (Battery charger)
600W
1 second (approx.)
14 ml/min
0.4 Liter (0.11 Gallon)
Air Guard Antibacterial Solution
0 °C – 40 °C (32 °F-104 °F)
Manual, Timer, Radio Wireless Remote
L293 W108 H238 mm (L11.54 W4.25 H9.37 inch)
8.5 kg (18.74 lbs)
---|---
M22 Moisture Co., Ltd.
Tel : +886 3 2227470 Fax : +886 3 2227469
www.airguard.com.tw e-mail :
sales@airguard.com.tw
C08AG0202
Documents / Resources
|
AirGuard AG-20 Antibacterial
Vaporizer
[pdf] User Manual
AG-20, Antibacterial Vaporizer, C08AG0202, 20201029
---|---