BEGA 12 127.1 Ceiling and Wall Luminaire for Indoor Use
Product Information
- Product Description: Luminaire made of Aluminium, finish Colour white Hand-blown crystal glass, white inside, with screw-neck Silicone gasket
- Distance apart: 200 mm
- 2 cable entries for through-wiring for mains with plug connection
- Earth conductor connection
- 2-pole connecting terminal for LED power supply unit 220-240 V x 0/50-60 Hz DC 176-276 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 64
- Dust-tight and protection against splash water
- Impact strength IK06
- Weight: 3.1 kg
- This product contains light sources of energy efficiency class(es) D
Product Usage Instructions
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage Protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e.g. transients, etc., we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Product Specifications
- Lamp Module connected wattage: 13.8 W
- Luminaire connected wattage: 16 W
- Rated temperature
- Ambient temperature
Module Information
- Module designation: LED-0854/930
- Color temperature: 3000 K
- Color rendering index (CRI): > 90
- Module luminous flux: 2255 lm
- Luminaire luminous flux: 985 lm
- Luminaire luminous efficiency: 61.6 lm / W
DIMENSION
Instructions for use
Application
Ceiling and wall luminaire · indoor luminaire made of aluminium and hand-blown
crystal glass. For a variety of interior lighting applications.
Product Description
- Luminaire made of Aluminium, finish Colour white
- Hand-blown crystal glass, white inside, with screw-neck
- Silicone gasket
- 2 mounting holes ø 5.5 mm
- Distance apart 200 mm
- 2 cable entries for through-wiring for mains supply
- cable up to ø 10.5 mm max. 5 G 1.5@
- Connecting terminal 2.5@ with plug connection
- Earth conductor connection
- 2-pole connecting terminal for digital control
- BEGA Ultimate Driver®
- LED power supply unit
- 220-240 V x 0/50-60 Hz
- DC 176-276 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains
- and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect
- temperature-sensitive components without
- switching off the luminaire
- Safety class I
- Protection class IP 64
- Dust-tight and protection against splash water
- Impact strength IK06
- Protection against mechanical
- impacts < 1 joule
- r – Safety mark
- c – Conformity mark
- Weight: 3.1 kg
This product contains light sources of energy efficiency class(es) D
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e. g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Lamp
- Module connected wattage 13.8 W
- Luminaire connected wattage 16 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 45 °C
12 127.1 K3
- Module designation LED-0854/930
- Color temperature 3000 K
- Color rendering index CRI > 90
- Module luminous flux 2255 lm
- Luminaire luminous flux 985 lm
- Luminaire luminous efficiency 61,6 lm / W
Installation
- LED are high-quality electronic components! Please avoid touching the light output
- openingof the LED directly during installation or relamping.
- Remove glass from luminaire housing by turning it counter-clockwise.
- Disassemble LED module.
- Loosen LED-connection and earth connection (plug connection).
- Lead the mains supply cable through the cable entry into the luminaire housing.
- Fix luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
- It is absolutely essential to use the enclosed gaskets.
- Push silicone sleeves over the lines, make ground and electrical connection to the terminals.
- For digital control please use the connecting terminal (DALI).
- In case this connector is not used the luminaire will be operated at full light output.
- Make earth connection between LED module and luminaire housing (plug connection).
- Push plug into coupler as far as it will go.
- Assemble LED module.
- Screw glass with gasket firmly into the luminaire housing by turning it clock-wise.
- Make sure that gasket is positioned correctly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Inspect and,
if necessary, replace the luminaire gaskets. Defective glass must be replaced.
Close the luminaire.
Spares
- Spare glass 11 003 081 47R G
- LED power supply unit DEV-0312/500
- LED module 3000 K LED-0854/930
- Gasket glass 83 000 367
CONTACT
- BEGA Gantenbrink-Leuchten KG
- Postfach 31 60
- 58689 Menden
- info@bega.com.
- www.bega.com.