BEGA 50696.2 Recessed Ceiling Downlight Instruction Manual

June 12, 2024
BEGA

**BEGA 50696.2 Recessed Ceiling Downlight Instruction Manual

**

Dimension

Dimension

Application

Recessed ceiling luminaire · indoor luminairewith direct and indirect light distribution for connection to an external LED power supply unit.
For surface-mounted installation in indoor suspended ceilings of 5-25mm thickness.

Product description

Recessed luminaire without power supply unit
Luminaire housing made of cast aluminium
Installation housing is made of glass-fibre
reinforced polyamide with 2 fastening springs
Reflector made of pure anodised aluminium
Light-diffusing silicone lens
Ceiling trim ring finish, Stainless steel
Hand-blown opal glass, satin matt
Recessed opening ø 130mm
Required installation depth 95mm
1 connecting cable with strain relief and plug connector system for BEGA power supply unit,
on/off or DALI
Safety class III 3
c – Conformity mark
Weight: 1.1 kg
This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage: 8.1 W
Luminaire connected wattage: 9.8 W
Rated temperature: ta=25 °C
Ambient temperature: ta max=55 °C
When installed in heat-insulating material: ta max=35 °C

50 696.2K3
Module designation: LED-0800/930
Colour temperature: 3000 K
Colour rendering index: CRI > 90
Module luminous flux: 1255 lm
Luminaire luminous flux: 838 lm
Luminaire luminous efficiency: 85,5 lm/W

Lighting technology
Half beam angle 50°

Installation

A separate power supply unit is required to operate the luminaire.
For connection to external LED-power supply unit – accessory 13 143 or 13 168 – the luminaire is equipped with a 2-pin connector.
Note operating instructions of the LED-power supply units.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the installation housing in the recessed opening is achieved by using two adjustable springs.

Installation into inserted ceilings:

A recessed opening of 130 mm is necessary to accept the installation housing. Recessed depth min. 95 mm.
Compress the fastening springs of the installation housing against their spring pressure on both sides towards the housing and slide the installation housing into the recessed opening.
The fastening springs catch the ceiling panel from the back side. Minimum thickness of the ceiling panel is 5 mm. If minimum thickness of the panel is less than 5 mm it must be reinforced from the reverse side. Maximum thickness of the ceiling panel must be no more than 25 mm.

Connect to the LED power supply unit.
Route the LED power supply unit through the installation housing and place it in the suspended ceiling.
Connect the 2-pin plug connector between luminaire and external LED power supply unit.

Installation instruction

Press together the two internal fixing sliders inside the luminaire housing.
Push the luminaire housing to the end of the installation housing and then release the fixing sliders.
This mechanism ensures that the luminaire housing sits securely inside the installation housing.

Installation housing and external LEDpower supply unit must not be installed in heat-insulating material.

Please use the protective gloves provided for the installation to prevent finger prints on the reflector.
Place the reflector with silicone lens on the ceiling trim ring. Twist the ceiling trim ring complete with the attached reflector to the right to fix the assembly inside the luminaire housing.

Cleaning Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Close the luminaire.

Accessories

Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.

13 143 Power supply unit on/off
13 168 Power supply unit DALI

The power supply units are only suitable for the operation of one LED luminaire.

For the accessories a separate instructions for use can be provided upon request.

Spares

LED module 3000 K: LED-0800/930
Reflector: 75 002 722
Spare glass: 75 002 915

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689
Menden info@bega.com
www.bega.com 3/3