BEGA 33 788 House Number Luminaire Instructions

June 12, 2024
BEGA

BEGA logo Technical amendments reserved
House number luminaire
Instructions

33 788 House Number Luminaire

BEGA 33 788 House Number Luminaire

Instructions for use

Application
House number luminaire with automatic twilight switch for one up to three- digit numbers or letters.
A luminaire made of aluminium alloy and crystal glass.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Crystal glass, white inside with 1-2 digit numbers lettering height 120 mm or with 3 digit numbers lettering height 75 mm
Silicone gasket
Integrated twilight switch with potentiometer for infinitely variable adjustment 2 mounting holes ø 5 mm
Distance apart 70 mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm
Connecting terminal and earth conductor terminal 2.5@
LED power supply unit
230 V y 50/60 Hz
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety mark
**** – Conformity mark
Weight: 3.4 kg
This product contains light sources of energy efficiency classes D, E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 6.8 W
Luminaire connected wattage 8.5 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 45 °C

33 788 K3

Module designation LED-0736/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 1135 lm
Luminaire luminous flux 182 lm
Luminaire luminous efficiency 21,4 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo lateral hexagon socket head screws on luminaire housing as far as they will go.
Swivel out luminaire housing.
Aperture angle: 100°.
In order to avoid an optical feedback (flashing operation of the luminaire) the distance between the photodiode of the twilight switch and reflecting objects must be min. 15 cm.
Lead the mains supply cable through the cable entry into the luminaire back housing.
Note position of application of the luminaire “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
The switch-on and switch-off values of the twilight switch can be infinitely variable adjusted by the potentiometer.
The complete adjusting range corresponds to 30 rotations (no stop).
The delivery condition of the potentiometer is positioned half-way so that one can turn 15 cycles clockwise or anti-clockwise to cover the complete adjusting range.
Swivel luminaire housing onto the luminaire base, press-on strongly and fix with hexgon socket head screws.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
When ordering spare glasses please advise figures or symbols.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

Spare glass 11 002 861 11
Twilight switch 61 000 515
LED power supply unit DEV-0451/350
LED module 3000 K LED-0736/830
LED module 4000 K LED-0736/840
Gasket twilight switch 83 000 297
Gasket housing 83 000 956
Gasket glass 83 000 978

BEGA Gantenbrink-Leuchten KG · Postfach 31 60
· 58689 Menden
· info@bega.com
· www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)