SereneLife SLPAC14 Compact Home Portable Air Conditioner User Manual

June 5, 2024
serenelife

SereneLife-SLPAC14-Compact-Home-Portable Air-Conditioner-
logo

SereneLife SLPAC14 Compact Home Portable Air Conditioner

Read all instructions carefully before setting up and operating the unit. Please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to set up, operate, maintain and troubleshoot your portable air conditioner. Failure to follow these instructions may damage and/or impair the operation and void the warranty.

Attention Points

For the health of you and your family, please read the following carefully before using the unit
Requirement:

  • Please place the unit in a flat and dry place. Keep the air conditioner 50cm. away from the surrounding objects.
  • The power supply of the air conditioner shall comply with the safety specifications for the use of the ground, and ensure reliable grounding.
  • After the air conditioner is installed, make sure that the plug is intact and firmly inserted into the socket.
  • Keep the air inlet and outlet unobstructed.
  • If the power cord is damaged, in order to avoid danger, it must be replaced by professional personnel from the manufacturer’s maintenance department or similar departments.
  • This unit should be away from gasoline, stove, or other combustibles and heat sources.
  • Always place the wires orderly to avoid tripping or pulling the plug out.
  • Use the power cord correctly. If it is damaged, please turn off the air conditioner immediately and pull out the plug. To avoid danger, please find a professional maintenance department or personnel for maintenance.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
    Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Prohibition:

  • This air conditioner is for household use only and should not be used on other occasions.
  • Do not install the unit in the laundry room or other places with water and humidity.
  • Do not turn on or off the unit by plugging in or pulling out the plug.
  • Do not put things on this unit.
  • Do not put anything into the air inlet and outlet.
  • Do not use insecticide sprays or other combustible substances near the air conditioner.
  • Do not splash oil or water into the air conditioner.
  • Do not use water to clean the air conditioner. Wipe it with a semi-wet soft cloth.
  • Do not use chemical solvents such as benzene, gasoline, alcohol, etc. to wipe the air conditioner. Please use neutral detergent if it is dirty.

Suggestion:
When the ambient temperature is higher than 40°C/104°F in cooling mode or lower than 7°C/44.6°F in heating mode, it is not recommended to use this unit.

Features and Parts

Features:

  • A new generation of condensate self-evaporation design, environmental protection, and energy-saving.
  • L-type evaporator design, more compact and efficient body.
  • Super high loading quantity, greatly saving logistics costs.
  • The whole unit is miniaturized and compact.
  • The exhaust hose assembly and other accessories are easy to install.
  • Self-diagnosis function and 24-hour power on/off timing function.
  • Universal wheel design, easy to move.
  • Silent design, suitable for sleeping.
  • Low noise and strong wind.
  • Three-minute delay to restart the compressor automatically.

Parts Name:SereneLife-SLPAC14-Compact-Home-Portable Air-Conditioner-
fig-1

  1. Control Panel
  2. Wind Guide Bar
  3. Exhaust Hose Assembly
  4. Casters
  5.  Handle
  6. Air Intake Grille
  7. Power Cord
  8. Filter
  9. Air Outlet.
  10. Power Cord Buckle
  11. Drainage outlet

Control Panel
Note:
If the machine is shut down in the cooling or heating operation state, it needs to wait for three minutes before it can be turned on automatically .SereneLife-SLPAC14-Compact-Home-Portable Air-Conditioner-
fig-1

Panel Description

  1. Button and Display

POWER: Press this key to turn the unit on or off.
MODE: Press this key to select cool mode, fan mode, or dry mode when starting or timing starts. When the mode is selected, the corresponding indicator lights up.
UP/DOWN: Press the key at cool mode to increase/reduce the set temperature; press it at timing mode to adjust time; press the Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature. SPEED: Press this key to select different wind speeds, low, medium, and high cycle selection, and the indicator light corresponding to the selected wind speed will be on.
TIMER: Press this key to enter the timing setting time state, and the indicator light is on.
88 DISPLAY: In cool mode, the pattern shows the set temperature. In fan and dry mode, the pattern shows the indoor temperature. When °C is displayed, it means that the current temperature is centigrade; when °F is displayed, it means that the current temperature in Fahrenheit.

  1. Remote control operating instructions

The operation interface of the remote control is as follows:

The key operation instructions of this high-quality remote control are as follows:

  1. POWER: Press the key to turn ON/OFF the unit.
  2. MODE: Press the key to choose cool, fan, and dry mode.
  3. UP: Press this key to increase the temperature and timing settings.
  4. DOWN: Press this key to decrease the temperature and timing settings.
  5. FAN: Press this key to cycle and select the output wind speed between the high, middle, and low wind speeds.
  6. TIMER: Press this key to set the timing.
  7. SWING: Press this key to turn on or off the pendulum. The air volume of the air outlet can be blown out at different angles.
  8. Press this key to switch between centigrade and Fahrenheit.

Multiple protection functions:
Frost protection function
In cool mode, dry mode, or economic energy-saving mode, if the temperature of the exhaust pipe is too low, the product will automatically enter the protection state. If the temperature of the exhaust pipe rises to a certain temperature, it can automatically return to normal operation.
Full water protection function
When the water in the water tray exceeds the warning level, the machine will give an alarm automatically, and the LCD temperature display area will display “FL”. At this time, you need to connect the machine or the water outlet with the drainage pipe, move it to the sewer and other drainage places to discharge the water
(see the “drainage instructions” at the end of this chapter for detailed drainage methods), and the machine will automatically return to the original working state after the water is discharged.
Protection function of a compressor
In view of the life protection of the compressor, the machine has a 3-minute delay protection function after the compressor is shut down.1

Operation Method

Time Setting

The setting of timing shutdown
In the running state of the machine, press the timing key, the timing LED will be on, and the 88 display will flash “0” 5 times. At this time, press the up and down keys to adjust the time from 1 hour to 24 hours, and change it for 1 hour for each up or down adjustment. When the set time is up, the machine will shut down automatically.
The setting of timing start up
When the machine is in standby mode, press the timing key, the timing LED will be on, and the 88 display will flash “0” five times. At this time, press the up and down keys to adjust the required timing time, which is the same as timing shutdown. When setting the time, you can select the working mode after starting the machine. If you select the cooling or heating mode, you can adjust the set temperature at the same time. When the set time arrives, the machine will start automatically and operate in the selected working mode.
Change the setting time
In the process of timing operation, if you want to change the existing timing time, you can press the timing key once. At this time, the 88 display will flash to display the remaining timing time. During the flashing period, press the up and down keys to increase or decrease the timing time on the basis of the original time. If you press the timer key again while flashing, the set time will be canceled, that is, exit the timer.

Operation mode

  1. Cool mode
  • Press the mode key to select the refrigeration mode in the start-up or timing start-up state. At this time, the corresponding LED on the panel is displayed.
  • Press the up and down keys to set the appropriate temperature. The setting range is 16~30°C (60-86°F). Each time you press the up or down key, the temperature will rise or fall by 1°C or 1°F.

Press the wind speed key to select the appropriate wind speed, which can cycle to select low, medium,2. Dry mode
• Press the mode key to select the dry mode in the start-up or timing start-up state. At this time, the corresponding indicator light is on.
• Temperature and wind speed are not adjustable.
Fan mode

  • Press the mode key to select the fan mode in the start-up or timing start-up state. At this time, the corresponding indicator light is on.
  • Press the wind speed key to select the appropriate wind speed, which can cycle to select low, medium, and high wind.
  • The temperature is not adjustable. and high wind. After the cool mode is selected, press and hold the up key and timing key on the operation panel at the same time to enter the sleep mode, and the wind speed of the upper and lower fans is forced to be set to low wind. To cancel sleep, press the key combination again or change the mode to cancel the sleep function.

Note:

  1. When the full water indication is displayed, the machine will stop working. You should drain the water in time, and then the machine can start up and run normally.
  2. In dry and fan mode, you may not use the exhaust duct.
  3. If your room is facing the sun, please close the curtains.

Installation

Select installation location

When the machine is installed in a flat and dry place, 50 cm space must be left around the machine to make the air flow smoothly. As shown in Figure 5, the best installation distance is 50 cm from the back of the machine body to the wall and 90 cm from the air outlet to the ground.

Assembly method of an exhaust pipe

  •  Connect the exhaust pipe assembly with the round joint (as shown in Fig. 6).
  • Fix the circular end of the connected exhaust pipe assembly at the air outlet of the machine according to the direction shown in Fig. 7.
  • Connect one end of the oblate joint of the connected exhaust pipe assembly with the window sealing plate.
  • Install the seal to the nearest window. Make sure there is no obstacle within 50 cm outside the window to ensure smooth exhaust.

Note:
The length of the exhaust duct is between 60cm and 170cm (including the adapter). We suggest using the minimum length, which can save energy for you.

The length of the exhaust duct is specially designed according to the specification of the air conditioner. Do not use exhaust pipes of different lengths or materials, which may cause failure.

Note: the above exhaust pipe and installation method are standard configurations of the company, subject to the actual object.

Installation of window sealing plate

Window sealing panels are designed to meet most standards for horizontal or vertical windows. The steps are as follows:

  1. Measure the window size;
  2. Adjust the length of the window sealing plate to adapt to the size of the window;
  3. After the length of the window, the sealing plate is determined, and the length size is fixed with screws;
  4. Install the fixed window sealing plate on the window;
  5. Clip the exhaust pipe assembly (flat end of exhaust nozzle) into the window sealing plate assembly, and use the Screw fixation.

Installation diagramSereneLife-SLPAC14-Compact-Home-Portable Air-
Conditioner-fig-7

Drainage Operation

  • When the refrigeration mode or drying mode is operated in wet weather, there is a lot of condensed water. When the water level of the water receiving tray reaches a certain position, the water full alarm will be issued to stop the compressor. The indicator of full water on the display will be on, and the alarm will sound at the same time until the water level of the water receiving tray is lower than the alarm level or the water of the water receiving tray has been drained manually. When the machine works normally, it will return to normal.
  • When the machine sends out the full water alarm, please drain the water in time. You can move the machine to a place where you can directly drain water (such as a toilet or sewer), screw off the nut, and pull out the water plug. Drain the water, and install the water plug and nut before use.

Note:
When the water is full, please move the machine smoothly, otherwise, the water may overflow from the inside.

Maintenance

Cleaning
Note: Please turn off the machine and pull out the plug before cleaning.

Clean the surface

Clean the surface of the machine with a duster or semi-wet soft cloth. Do not use chemical reagents, such as benzene, alcohol, gasoline, etc. Otherwise, the surface of the air conditioner will be damaged, even the whole machine will be damaged.

Cleaning of filter screen

  • If the filter is blocked by dust, it will lead to poor air circulation and reduce the efficiency of air conditioning.
  • In the case of long-term use of air conditioning, it is recommended to clean the filter every two weeks.
  1. Pull out the filter in the direction shown in Figure 13.
  2.  Put the filter into the warm water (about 40°C/104°F) with neutral detergent to clean it, and then dry it in the shade.

Post Season Preservation
When the air conditioner is not used for a long time or after the season, corresponding maintenance measures should be taken.

  • Completely drain the water from the drain outlet of the water tray inside the machine (tilt the machine body back slowly to pour out the water during the drainage process), then adjust the working mode to the air supply mode, and then press and hold the wind speed key for 5 seconds until the downdraft fan works. Keep this working state for 2 ~ 3 hours. This method can make the body dry and prevent mildew.
  • Turn off the machine and pull out the power plug.
  • Wind the wire tightly and put it in place.
  • Remove the exhaust pipe and keep it properly.
  • Cover the air conditioner with a plastic bag and put it in a dr9 y place.
  • Take out the battery of the remote control and keep it properly.

TROUBLESHOOTING

Before contacting a professional electrician, please check as follows:

TROUBLE CAUSE SOLUTION
  Is the power off? Normal phenomenon.
The air conditioner doesn’t work Is the plug not inserted?

Is the fuse blown or closed?

Is the time setting appropriate? Is there a full water warning?

| Plug in the power plug. Replace the fuse or turn on the power.

Change the time setting.

 |  | Pour out the water.
 | Is the air inlet and outlet| Remove the blockage. Remove other heat sources. Clean the filter screen.

Change the temperature. Choose the right wind speed.

 | blocked?
 | Is there any other heating
The air| source in the room?
conditioner is| Is the filter too dirty?
not cooling| Is the temperature setting

appropriate?

 | Is the fan speed set to the
 | lowest gear?
The air|  |
conditioner is|  |
not standing securely, too

much noise,

| Is the fuselage tilted? Is the ground uneven?| Put it on the ground.
and shaking|  |
while running|  |

Note:

In case of the following abnormal conditions, turn off the air conditioner and pull out the plug, and then contact the professional electrician

  • The fuse often breaks
  • The power cord is overheated or the skin of the cord is exposed
  • The body produces an abnormal odor

Intelligent detection function

Error-detecting code Multi-functional defection
E1 Coil sensor sensing abnormal
E2 Abnormal perception of room temperature sensor
E4 Anti-freezing protection
FL The machine is in full water alarm state

Do not place the waste separately for other special purposes

FEATURES:

  • Removes up to 50 pints/24 hours with Continuous Drain Option for Long Unattended Operation
  • Automatic Self-evaporation Technology
  • Metal Control Box to Prevent Fire and Exploding
  • Rotary Compressor
  • Universal Castors for Moving Freely
  • Wifi function
  • Lightweight & Portable A/C Unit
  • Compact Freestanding Room Air Conditioner
  • (3) Operation Modes: AC Cooling / Dehumidifier / Fan
  • Hassle-Free, Quick Setup Cooling
  • Simple Electric Plug-in Operation
  • Convenient Wide-Area Climate Control Room AC Coverage
  • Push Button Control Panel with LED Display
  • Time, Temperature & Fan Speed Adjustment Settings
  • Includes Universal Window Mount AC Exhaust Kit
  • Removable & Washable Air Filter Screen
  • Modern Style, Sleek Body Housing
  • Energy Efficient: Low Power Consumption
  • Low Noise Level Motor
  • Rolling Wheels for Easy Portability
  • Used for Home, Office, School & Business Rooms

WHAT’S IN THE BOX:

  • AC Unit
  • Exhaust Hose
  • Window Installation Plate
  • Remote Control

TECHNICAL SPECS:

  • Power Supply: 115V/60Hz

  • Rated Power: 1220W

  • Refrigerant Type: R32

  • Cooling capacity (ASHRAE): 14,000 Btu/h

  • Cooling capacity (DOE): 10,000 Btu/h

  • Coverage Area: Cools Rooms up to 500 Square Feet

  • Air Flow: 400 Cubic Meters / Hour

  • Operating Modes: Cool / Fan / Dry (Dehumidifier)

  • Moisture Removal / Dehumidifier: 1.5 Liters / Hour

  • Operating Noise Level: 57 dBA
    Fan Speed Settings: Three Level, Low/Medium/High

  • Temperature Unit Selectable: °C / °F (Celsius / Fahrenheit)

  • Adjustable Timer Settings: Up to 24 Hours

  • Construction Material: High Impact Polystyrene (HIPS)

  • Battery Operated Remote Control, Requires (2) x ‘AAA’ Batteries, Included

  • Power Cable Length: 4.3’ ft.

  • Extendable Exhaust Hose Diameter: 5.9 in

  • Extendable Exhaust Hose Max: 59 in

  • Extendable Window Kit: 26.6-49.7 in

  • Product Dimension (L x W x H): 32” x 18.5” x 15.4” -inches

WARNING:

This product can expose you to a chemical or group of chemicals, which may include ”Acrylonitrile” which is known in the sta9t e of California to cause cancer, birth defects, or other reproductive harm. For more info, go to https://www.p65warnings.ca.gov/.

  • Questions? Issues?
  • We are here to help!
  • Phone: (1)718-535-1800
  • Email: support@pyleusa.com

Documents / Resources

| SereneLife SLPAC14 Compact Home Portable Air Conditioner [pdf] User Manual
Compact Home A C Cooling Unit with Built-in Dehumidifier, SLPAC14, Compact Home Portable Air Conditioner, SLPAC14 Portable Air Conditioner, Portable Air Conditioner, SLPAC14 Compact Home Portable Air Conditioner
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

serenelife User Manuals

Related Manuals