Laserliner ThermoVisualizer Pocket IR Camera Instruction Manual
- June 10, 2024
- Laserliner
Table of Contents
Laserliner ThermoVisualizer Pocket IR Camera
The ThermoVisualizer Pocket is a handheld device that allows you to measure and visualize temperature through infrared technology. The device features a mini USB interface, a ThermoArray sensor, and the ability to store data and BMP images. The device also features a 1.8-inch TFT color display with a resolution of 128 x 160 pixels and a 9 Hz image frequency. The device can be powered by four 1.5VLR03 (AAA) batteries and has a battery life of approximately 100 hours.
Product Usage Instructions
- Before using the device, read the user manual and warranty information carefully.
- Insert four 1.5V LR03 (AAA) batteries into the battery compartment located on the back of the device.
- Press the ON/OFF button to turn on the device.
- To measure temperature, point the device at the object or area you want to measure and press the trigger button to capture an image
- Use the arrow buttons to navigate through the different temperature readings displayed on the screen, including the minimum and maximum temperatures.
- Use the SET button to access additional features such as changing the color palette, adjusting the emissivity, and setting the date and time.
- To save images, press the trigger button while aiming at an object, and then press the SET button to save it to the device’s memory or to an inserted micro-SD card.
- To turn off the device, press and hold the ON/OFF button for two seconds.
- Store the device in a cool, dry place when not in use.
**
ThermoVisualizer Pocket**
Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.
Function / Application
The thermal imaging camera provides visualisation of temperature curves, energy losses, thermal bridges, electrical overloads and moisture build-up. The infrared image, digital image and mix image allow the user to have a flexible illustration of the area under inspection. Images are stored on exchangeable Micro-SD cards. The device features a USB interface and a high- contrast, colour TFT display
General safety instructions
- The device must only be used in accordance with its intended purpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
- Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
- The device must no longer be used if one or more of its functions fail or the battery charge is weak.
Safety instructions
Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
- The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
PARTS DESCRIPTION
-
ON/OFF
-
1,8“ colour display
-
Menu navigation / select digital image, overlay infrared / digital image Menu / Control menu (Confirmation)
-
Menu navigation /
-
select digital image, overlay infrared / digital image
-
Battery compartment
-
Shaft
Mini USB interface
Micro-SD card slot -
Control menu (cancel / back)
-
Infrared sensor
-
Digital camera
-
Trigger: save image
Standard measurement view
- Battery charge indicator
- Micro-SD card not inserted
- Temperature at centre of image
- Min. temperature
- Max. temperature
- Thermography image
Main Menu
- Change color palette
- Set emissivity coefficient
- Open media gallery / Delete images from micro-SD card
- Auto shutdown
- Set date/time
Inserting batteries
Open the battery compartment and insert batteries according to the symbols.
Be sure to pay attention to polarity ****
ON / OFF
Inserting micro-SD card To insert a micro-SD card, first open the rubber cover and then insert the memory card as illustrated. You cannot record anything without a storage medium.
WARNING
The device must be switched off before removing ! the micro-SD.
Main menu
General and measurement-specific settings can be made in the main menu. The
menu is controlled with the four buttons (3, 4, 5, 8)
Colour ranges IR image
You can choose from several standard colour ranges to represent the
measured infrared temperatures. Depending on the colour palette, the measured
temperatures are adjusted within the current image section and displayed in
the respective colour space.
Emissivity coefficient
The level of infrared emissions given off by everything depends on the
specific material and surface. This factor is determined by the emissivity
coefficient (0.10 … 1.0). For accurate measurements, it is absolutely
essential that the emissivity coefficient is set first. The emissivity
coefficient can either be custom set or selected from the predefined
emissivity coefficients from the list.
Emission coefficient tables Reference values with tolerances
Media gallery / playback mode
All image data recorded with the ThermoVisualizer Pocket is available in
the media gallery.
To delete recording
WARNING
The files are deleted immediately. ! There is no prompt to confirm deletion.
Auto power off
The device switches off automatically after a set period of inactivity
Date / Time
Image modes
There are 6 image modes to choose from.
- A. IR image (Thermal image)
- B. – E. Digital image with IR image overlay (MIX), 4 stages
- F. Digital image (black/white)
Data transfer
Data saved on the micro-SD card can be transferred to PC either with a
suitable card reader or via the mini-USB port. Please refer to the manual
supplied with your card reader for information about connecting your card
adapter or card reader to a PC.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The measuring device must be calibrated and tested on a regular basis to
ensure it is accurate and working properly. We recommend carrying out
calibration once a year. Contact your distributor or the UMAREX-LASERLINER
service department.
Technical data
(Subject to technical changes without notice. Rev22W03)
EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: www.laserliner.com
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>