BEGA 24 653 Ceiling Wall and Pillar Luminaire

Product Information

Product Name Decken-, Wand- und Pfeilerleuchte
English Translation Ceiling, wall and pillar luminaire
Product Description Luminaire made of stainless steel
Steel Grade No. 1.4404
Glass Type Opal glass with screw neck
Gasket Silicone gasket
Mounting Plate With 2 fixing holes and plug connection
Lampholder G9
Safety Class I
Protection Class IP64 (Dust-tight and protection against splash water)
Impact Strength IK06
Weight 0.49 kg
Lamp Output Maximum 33 W
Luminaire Efficiency 74.8%

Product Usage Instructions

  1. Ensure the luminaire is installed and operated according to national safety regulations.
  2. Installation and commissioning should only be carried out by a qualified electrician.
  3. The manufacturer does not accept liability for damage caused by improper use or installation.
  4. If modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.
  5. To install the lamp, open the luminaire and insert the lamp with lampholder G9.
  6. Screw the opal glass into the frame by turning it to the right.
  7. Ensure the gasket is properly positioned.
  8. Open the luminaire and clean it using suitable cleaning products. Do not use high-pressure cleaners for cleaning.
  9. Avoid using cleaning agents that contain cement, glue, paint, etc.
  10. For cleaning, strictly follow the instructions provided.

Instructions for use

Application

Unshielded luminaire made of stainless steel for installation under ceilings, on walls as well as on pillars and murals. By means of the three-ply opal glass the light is distributed softly and uniformly over the glass surface.

DIMENSION

BEGA-24-653-Ceiling-Wall -and-Pillar-Luminaire-FIG-
\(1\)

Product Description

  • Luminaire made of stainless steel
  • Steel grade no. 1.4404
  • Opal glass with screw neck
  • Silicone gasket
  • Mounting plate with 2 fixing  holes ø 4.5 mm · 50 mm spacing
  • 1 cable entry for mains supply cable
  • up to ø 10,5 mm
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • Lampholder G 9
  • Safety class I
  • Protection class IP 64
  • Dust-tight and protection against splash water Impact strength IK06
  • Protection against mechanical
  • impacts < 1 joule
  • Safety mark
  • Conformity mark
  • Weight: 0.49 kg

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

  • Luminaire with lampholder G 9
  • Lamp output max. 33 W
  • This product contains light sources of energy efficiency classes E, F

Supplied lamp

  • BEGA LED lamp 13 597
  • LED Retrofit 4 W · 400 lm · 3000 K dimmable
  • Luminaire efficiency: 74.8%
  • Additional BEGA LED lamps are available for this luminaire:
  • 13 598 LED 4 W · 390 lm · 2700 K dimmbar

Detailed technical and lighting data for the lamps can be found in the data sheets on our website.

Installation

  • Remove glass from luminaire housing by turning it counterclockwise.
  • Undo screws (key slots) and remove the luminaire housing from the mounting plate. Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied. Make earth conductor connection.
  • Push silicone sleeves over the lines and make electrical connection.
  • Place the luminaire housing onto the mounting plate and fix with screws.
  • Insert lamp.
  • Screw the glass into the luminaire housing by turning it clockwise.
  • Make sure the seal is properly located.
  • Relamping · Maintenance
  • Disconnect the electrical installation.
  • Open the luminaire and clean.
  • Use only solvent-free cleaning agents. Change the lamp.
  • Check the gasket and replace, if necessary. Close the luminaire.
  • For cleaning, do not use high-pressure cleaners.

Cleaning Maintenance

After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made
of normal steel, steel brushes or steel wool because they cause extraneous rust to form. When using stainless steel cleaners, please read the directions carefully.
Cleaning agents containing hydrochloric acid and chlorides should never be used.
We recommend cleaning the luminaires regularly.

Spares

  • Spare glass 11 002 545 41
  • LED lamp 3000K 13 597
  • Lampholder 63 000 259
  • Gasket glass 83 000 734