BEGA 50 910.4 Wall Luminaire For Indoor Use Instruction Manual

June 12, 2024
BEGA

BEGA 50 910.4 Wall Luminaire For Indoor

Product Information
This product is a wall luminaire from the STUDIO LINE series. It features a white metal housing with a matt brass inside hue. The luminaire has a synthetic cover that is translucent white. It is equipped with a LED power supply unit that operates at 220-240 V and 50-60 Hz, with a DC output of 196-250 V. The luminaire is DALI-controllable and has basic insulation between the mains and control lines. It also has temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire. The weight of the luminaire is 4.5 kg. The product contains light sources of energy efficiency classes D.

Product Usage Instructions

  1. The installation and operation of this luminaire must comply with national safety regulations.
  2. Installation and commissioning should only be carried out by a qualified electrician.
  3. Ensure that the luminaire is properly connected to the main cable using the connecting terminals.
  4. If using digital control, connect the luminaire to a 2-pole connecting terminal for digital control.
  5. For additional protection against overvoltage or transients, it is recommended to use separate overvoltage protection components. These can be found on the manufacturer’s website at www.bega.com.
  6. When replacing the cover, follow the module mounting instructions in reverse.

Wall luminaire for indoor use

BEGA-50 910.4-Wall-Luminaire-For-Indoor-fig-1

Instructions for use

Application
Wall luminaire · Indoor luminaire with velvet white metal housing. Luminaire with light source shielded to the front and metallic inside color of the reflection surface. Radial light emission 360°.

Product Description
Wall luminaire “STUDIO LINE” Aluminium luminaire housing, finish Colour velvet white inside hue matt brass Synthetic cover, translucent white 2 mounting holes ø 4.5 mm Distance apart 190 mm 1 cable entry for through-wiring for mains cable Connecting terminals 2.5@ Earth conductor terminal 2-pole connecting terminal for digital control LED power supply unit 220-240 V x 0/50-60 Hz DC 196-250 V

DALI-controllable
Basic insulation is provided between the mains and control cables

BEGA Thermal Control
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire

  • Safety class I
  • c  – Conformity mark
  • Weight: 4.5 kg
  • This product contains light sources of energy efficiency classes D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 23.1 W
  • Luminaire connected wattage 25.8 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C
  • 50 910.4 K3
  • Module designation LED-1174/930
  • Color temperature 3000 K
  • Color rendering index CRI > 90
  • Module luminous flux 3655 lm
  • Luminaire luminous flux 699 lm
  • Luminaire luminous efficiency 27,1 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping. Remove the mounting plate with the LED unit from its packaging. Loosen the knurled screw (slotted) and remove the ring made of synthetic material from the LED unit. Pass the power connecting cable through the cable entry in the mounting plate. Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface. Establish the earth conductor connection on the earthing screw (1) of the mounting plate. Make the electrical connection to the terminals. Observe the correct configuration of the connecting cable. Connect the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N). The two connecting terminals marked DA, and DA are provided for digital control purposes. If these terminals are not assigned, the luminaire will work with full light output. Insert the ring made of synthetic material back into the LED unit and tighten the knurled screw (slotted). Unpack the luminaire housing and carefully guide it over the LED unit. Position and align the luminaire housing on the mounting plate and tighten the locking screw on the side.

Cleaning · Maintenance
Clean the luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module
Replacing the power supply unit The designation of the LED module is noted on a label in the luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools. Disconnect the system from the power supply. Loosen the locking screw on the side and lift the luminaire housing off the mounting plate. Loosen the knurled screw (slotted) and remove the ring made of synthetic material from the LED unit. Disconnect the earth conductor connection and the electrical connection to the terminal. Loosen the mounting screws of the power supply unit, the round blank bracket and earthing screws (Torx). Remove the pot with an LED module. Install the replacement pot. Please follow the installation instructions for the LED module. Replace defective LED power supply unit. Install in reverse order.