Honeywell HE365A Powered Flow-Through Humidifier Owner’s Manual
- June 5, 2024
- Honeywell
Table of Contents
This is a legacy product document supported by Resideo. It is no longer manufactured
HE365A, B Powered Flow-Through Humidifier with
OWNER’S GUIDE
IMPORTANT
Please read these instructions and keep them in your records.
OPERATING YOUR HUMIDIFIER
HE365A
The H8908B Convertible Humidity Control controls your Enviracaire Elite™ HE365A Humidifier from Honeywell. The convertible humidity control is installed either on an interior wall in the living area or on the return air duct. Choose the humidity control setting using the combination relative humidity/ outdoor temperature setting scale on your humidity control dial. Match the dial set to the outdoor temperature for optimizing the humidity level while reducing the moisture condensation on your windows. The table below can also adjust the humidity control to the recommended setting.
At Outside Temperature| Recommended Control Setting| At
Outside Temperature| Recommended Control Setting
---|---|---|---
-20°F (-29°C)| 15| +10°F (-12°C)| 30
-10°F (-23°C)| 20| +20°F (-7°C)| 35
0°F (-18°C)| 25| Above 20°F (-7°C)| 40
NOTE: As the outside temperature drops, the recommended humidity control
setting is lowered to accommodate for the effects of dewpoint. These settings
should reduce the accumulation of moisture and ice on your windows and in
other areas of your home.
Some indoor activities such as cooking, showering, and clothes drying can
cause excessive levels of humidity and start the accumulation of moisture on
your windows.
NOTE: If this condition persists for more than a few hours, set the
humidity control to the lowest setting to turn off the humidifier. If the
condition does not improve, ventilate your home to remove the moisture.
HE365B
Your Enviracaire Elite™ HE365B Humidifier is controlled by the Honeywell H1008
Automatic Humidity Control with HumidiCalc+™. The automatic humidity control
is mounted in the return air duct where it can be exposed to the air stream of
the return air.
The HumidiCalc+™ software inside your automatic humidity control is designed
to measure or infer outdoor temperature and automatically adjust the humidity
based on the frost factor setting that the homeowner sets to allow for
variances in furnace size, window type, and insulation.
The Automatic Humidity Control with HumidiCalc+™ requires some initial
adjustments when you first install your HE365B. For maximum humidification,
set the H1008 to 10 and run the fan continuously. Check for condensation on
windows after a cold night. If there is no condensation, leave the setting at
10. If there is condensation, lower the
frost factor dial one setting. Continue to check for condensation on cold
mornings until the correct humidity setting is reached for your home. Allow
two days between adjustments to determining if further adjustment is
necessary. Once you have tuned in to the proper setting, you should never have
to adjust it again. HumidiCalc+™ takes over
and makes any future adjustments caused by varying outdoor temperatures, thus
reducing moisture build-up on windows while maintaining the optimal humidity
level.
Humidity Level | Recommended Setting |
---|---|
Insufficient humidity | Increase the frost factor dial by one setting. |
Condensation on windows | Decrease the frost factor dial by one setting. |
HOW YOUR HUMIDIFIER WORKS
Your Enviracaire Elite™ humidifier uses the principle that vapor (evaporated
water) is created when warm air blows over a water-soaked area. As the vapor
circulates, the relative humidity rises.
Your humidity control monitors the relative humidity and activates the
humidifier accordingly. The humidifier has a water supply that dispenses water
evenly over the AgION™ antimicrobial humidifier pad. The warm dry air, from
the furnace, passes over the humidifier pad and picks up the moist air to
circulate it throughout your home.
Humidified air feels warmer and more comfortable so you may be able to lower
your thermostat heating setpoint, which saves money on your heating fuel
bills. The end result is that your humidifier gives you a cleaner, more
comfortable environment that is also energy efficient.
MAINTAINING YOUR HUMIDIFIER
A regular maintenance program prolongs the life of your humidifier and provides a more comfortable home. Frequency of cleaning depends on the condition of your water. You can use either hard or soft water in your humidifier, but hard water mineral deposits are more difficult to clean than soft water deposits. For optimum performance, Honeywell recommends replacing the AgION™ antimicrobial pad once a year. Use the following procedure to clean your Honeywell humidifier.
WARNING
Serious Personal Injury Hazard.
Can cause electrical shock and injury from moving parts.
Disconnect power and shut off the water supply before removing the cover.
IMPORTANT
Never oil any part of the humidifier.
Every 1 to 3 Months (Depending on Water Quality)
- Disconnect power and turn off the humidifier water supply.
- Remove the humidifier cover by unplugging the connector and loosening the thumbscrew. Grasp the cover near the bottom and pull it toward you.
- Remove the humidifier pad assembly from the humidifier by grasping the top of the tray and pulling it toward you.
- Lift the tray off the pad.
- Gently pinch the water nozzle and catches inward until you can lift the water nozzle off the tray.
- Carefully remove any mineral deposits from the tray and frame. Be sure the frame drain hole is not blocked.
- Disconnect the drain hose from the drain fitting on the bottom of the humidifier housing.
- Clean the drain fitting, if necessary.
- Bend the drain hose to loosen any mineral deposits.
- Flush the drain hose with pressurized water (a running tap) to clean the house.
- Reattach the drain hose to the drain fitting.
- Snap the water nozzle back on the tray.
- Be sure the marked end of the pad is facing up. Place the tray on the new pad.
- Place humidifier pad assembly in humidifier housing. Be sure the water feed tube is placed in guide slots.
- Replace the humidifier cover.
- See the Checking Your Humidifier for the Proper Operation section to verify operation.
End of Humidification Season
The humidifier needs to be cleaned and shut off at the end of the heating
season. See Every 1 to 3 Months section, steps 1 through 15, to shut down for
the season.
IMPORTANT
Be sure humidifier power is off.
Vacation
The humidifier water supply and your humidity control can be turned off. Turn
on the humidifier water supply and reset your humidity control when you
return.
CHECKING YOUR HUMIDIFIER OPERATION
After winter startup or servicing, check the humidifier operation:
-
Turn on the humidifier power and water supply.
-
Turn H8908B Control to the highest setting, or H1008A Control to test position; set thermostat to 10°F (6°C) above room temperature.
NOTE: The H1008A Automatic Humidity Control stays in test mode for thirty minutes. Then it automatically resets to the maximum frost factor setting. If system checkout is not completed in thirty minutes, the test mode can be extended by turning the dial setting back and then returning it to test mode. -
Observe that water is flowing out of the drain hose.
NOTE: The furnace blower must be on to activate the humidifier. -
Reset the thermostat and H8908A Control to a comfortable setting or H1008A Automatic Control to desired frost factor setting for automatic operation.
TROUBLESHOOTING YOUR HUMIDIFIER
Problem | What to Look for | What to Do |
---|---|---|
Low humidity | Furnace blower not operating. |
- Reset circuit breaker or replace fuse.
- Check that the furnace power is on.
- Check all external wiring connections.
- Check humidity control setting.
- Call a heating contractor.
Rapid air changes. Drafts (cold air is dry and is an added load to the humidifier).|
- Keep doors and windows closed.
- Close fireplace damper if not using.
- Minimize exhaust fan running time.
- Seal around doors and windows.
High humidity| Condensation on walls.|
- Turn off humidity control and water until condensation is completely evaporated.
Heavy condensation on windows.|
- Turn humidity control low enough to eliminate bath and cooking condensation moisture. If moisture persists, more ventilation is needed.
ADDING PERFECT CLIMATE® CONTROLS FOR COMFORT AND CONVENIENCE
- Honeywell Perfect Climate Comfort Center™ controls or Chronotherm® IV Programmable Thermostats.
- Honeywell media air cleaner or electronic air cleaners3.Honeywell humidistats.
- Honeywell humidifiers.
- Honeywell home ventilation systems.
Describing Perfection
The cleanest, healthiest, most convenient, energy-efficient, and comfortable
indoor environment possible today! Perfect climate is achieved when the
following five core components of a home’s climate system work together:
- optimal efficiency heating and cooling equipment,
- precise, programmable temperature control,
- effective indoor air quality control,
- controlled humidity,
- proper ventilation and air distribution.
Contact your local Perfect Climate® dealer for an evaluation of your home.
WARRANTY
Honeywell warrants this product, excluding the humidifier pad, to be free from
defects in the workmanship or materials, under normal use and service, for a
period of one (1)
year from the date of purchase by the consumer. If, at any time during the
warranty period, the product is defective or malfunctions, Honeywell shall
repair or replace it (at Honeywell’s option) within a reasonable period of
time.
If the product is defective, return it, with a bill of sale or other dated
proof of purchase, to the place where you purchased it.
This warranty does not cover removal or reinstallation costs. This warranty
shall not apply if it is shown by Honeywell that the defect or malfunction was
caused by damage
which occurred while the product was in the possession of a consumer.
Honeywell’s sole responsibility shall be to repair or replace the product
within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR
DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR
IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES OTHIS PRODUCT. THE
DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE
ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on
how long an implied warranty lasts, so the above limitation may not apply to
you. This warranty gives you specific legal rights, and you may have other
rights which vary from state to state.
If you have any questions concerning this warranty, please write Honeywell
Customer Care, 1985 Douglas Dr. N, Golden Valley, MN 55422 or call
1-800-468-1502. In Canada, write Retail
Products, ON15, Honeywell Limited/Honeywell Limitée, 35 Dynamic Dr, Toronto,
Ontario M1V 4Z9.
Automation and Control Solutions
Honeywell International Inc. Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North 35 Dynamic Drive
Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9
yourhome.honeywell.com
| Printed in U.S.A. on recycled paper containing at least 10% post-consumer
paper fibers.
---|---
® U.S. Registered Trademark
© 2008 Honeywell International Inc.
69-1427—04 M.S. Rev. 06-08
Documents / Resources
|
Honeywell HE365A Powered Flow-Through
Humidifier
[pdf] Owner's Manual
HE365A, Powered Flow-Through Humidifier, HE365A Powered Flow-Through
Humidifier
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>