AIRGUARD 7556 Blockage Prevention System Installation Guide
- May 15, 2024
- AirGuard
Table of Contents
- 7556 Blockage Prevention System
- Product Specifications
- Product Usage Instructions
- Step 1: Remove Existing Fan Screen
- Step 2: Install Mounting Bracket
- Step 3: Bolt Oil Cooler/Radiator Assembly
- Step 4: Mount Brackets
- Step 5: Attach Mesh Screen or Snorkel Housing
- Q: Can I skip certain steps if I am only installing the snorkel
7556 Blockage Prevention System
Product Specifications
- Product Name: AIRGUARD – Blockage Prevention System
- Part Kit Number: Varies
- Release Date: 2023-03-01
Product Usage Instructions
Step 1: Remove Existing Fan Screen
Remove the existing fan screen (Item 1) from the fan housing
(Item 2).
Step 2: Install Mounting Bracket
Install the supplied mounting bracket (Item 1) to the fan
housing (Item 2) using existing bolts and nuts (Item 3). Angle
mount the bracket in a position that ensures the supplied hydraulic
hoses reach the fan motor. Additional holes in the bracket face
(Item 4) are for easy access with an impact driver.
Step 3: Bolt Oil Cooler/Radiator Assembly
Bolt the Oil Cooler/Radiator Assembly (Item 1) to the BP System
Bracket (Item 2) using supplied 10mm x 25mm Bolts (Item 3) and 10mm
lock nuts (Item 4). If only installing the snorkel kit without the
radiator, then install plastic plugs (Item 5) onto the BP System
Bracket (Item 2).
Step 4: Mount Brackets
Remove the packaging materials prior to the assembly of these
brackets. Mount the BP System Main Bracket with Oil Cooler (Item 1)
or Main Bracket with Plugs (Item 2) to the Fan bracket (Item 3)
using supplied pivot pins (Item 4). Secure in place with 3.5mm
cotter pins (Item 5).
Step 5: Attach Mesh Screen or Snorkel Housing
Attach the Mesh Screen (Item 1) or Snorkel Housing (Item 2) to
the front of BPS using latches (Item 3).
Frequently Asked Questions (FAQ)
Q: Can I skip certain steps if I am only installing the snorkel
kit?
A: Yes, you can skip certain steps if you are only installing
the snorkel kit. Refer to Page 15 for remaining instructions on
Snorkel Mounting.
PART KIT INSTALL INSTRUCTIONS
Part Kit #VARIES – Rev 1.0 – AIRGUARD – Blockage Prevention System
Concord Aircarts
Release Date: 2023-03-01
Title STEP
Airguard Blockage Prevention System Upgrade Instructions 1. Remove existing fan screen (Item 1) from the fan housing (Item 2).
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
1 2
1 2
2
Item Part #
1
—
PARTS LIST Description Fan Screen
Aiguard Blockage Prevention System Upgrade Instructions
Item Part #
2
—
2023-03-01
PARTS LIST Description Fan Housing
1 Page 2
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
2. Install supplied mounting bracket (Item 1) to fan housing (Item 2) using
existing bolts and nuts (Item 3). Angle mount bracket in a position that
ensures the supplied hydraulic hoses reach the fan motor. Additional holes in
bracket face (Item 4) are for easy access with an impact driver. Bracket may
look different than shown below.
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
3
23
1 Additional holes in bracket face are for easy access with an impact driver.
Item Part #
1
7556 /or/ 7554
2
—
PARTS LIST Description 9540 Bracket /or/ 9520 Bracket Fan Housing
Aiguard Blockage Prevention System Upgrade Instructions
Use Kit # 9540 for the following Models: · 2300 · 2800 · 3400 · 3350
Use Kit # 9520 for the following Models: · 3800 · 5250
Item Part #
3
—
2023-03-01
PARTS LIST Description Existing Hardware
Page 3
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
3. Bolt Oil Cooler/Radiator Assembly (Item 1) to BP System Bracket (Item 2) using REV # supplied 10mm x 25mm Bolts (Item 3)and 10mm lock nuts (Item 4). If only installing PART KIT # snorkel kit without Radiator, then install plastic plugs (Item 5) onto BP Sytem Bracket (Item 2). This step of the installation may already be completed at the Airguard factory prior to shipping.
3
2023-03-01 1.0 Varies
5
5 4
2
Item Part #
1
7996
2
7546
3
7515
PARTS LIST Description Oil Cooler and Manifold Assembly Main BP System Bracket Hex Bolt, 10mm x 25mm Grade 8.8
Aiguard Blockage Prevention System Upgrade Instructions
1
Item Part #
4
7516
5
7683
2023-03-01
PARTS LIST Description Lock Nut, 10mm Grade 8.8 BP System Bracket Plug
Page 4
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
4. Remove the packaging materials prior to the assembly of these brackets. Mount BP System Main Bracket with Oil Cooler (Item 1) or Main Bracket with Plugs (Item 2) to Fan bracket (Item 3) using supplied pivot pins (Item 4). Secure in place with 3.5mm cotter pins (Item 5).
REV # PART KIT #
2023-03-01 1.0 Varies
4
Remove Packaging material
4
and discard, prior to install.
5 3
1
Item Part #
1
—
2
—
3
—
2
PARTS LIST Description BP System Main Bracket with Oil Cooler BP System Main
Bracket with Plugs for Snorkel Only Install Fan Bracket
Item Part #
4
7502
5
7513
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
PARTS LIST Description Pivot Pin For BP Systems 3.5mm Cotter Pin
Page 5
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
5. Attach Mesh Screen (Item 1) or Snorkel Housing (Item 2) to front of BPS
using latches (Item 3).
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
For Snorkel Only Installation Skip to Page 15 for remaining instructions on Snorkel Mounting.
3
3
2
Item Part #
1
7568
2
7977
PARTS LIST Description Mesh Screen Snorkel Housing
Aiguard Blockage Prevention System Upgrade Instructions
1
Item Part #
3
—
2023-03-01
PARTS LIST Description Overcenter Latch
Page 6
Title
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
STEP
6. Identify the model of aircart that the Airguard Blockage Prevention System is being REV #
installed on. For models with external check valves, the connections must be made on PART KIT # the tractor side of the hydraulic circuit as shown below.
Installation with External Check Valve: Pressure Connection
2023-03-01 1.0 Varies
Case Drain Connection
Installation with Internal Check Valve:
Return Connection
Pressure Connection
Return Connection
Aiguard Blockage Prevention System Upgrade Instructions
Case Drain Connection
2023-03-01
Page 7
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
7. Remove factory hoses (Item 1) from side of fan motor (Item 2). Remove the hos- REV #
es (Item 1) on the tractor side of the external check valve, as shown below. Identify which hose is the pressure side of the circuit. On newer models there is a shut off
PART KIT #
valve on the pressure side of the circuit. The external check valve will have a direction-
al arrow that always points to the pressure side. If you do not have an external check
valve you will attach directly to the fan motor.
PRESSURE
2023-03-01 1.0 Varies
3
RETURN 1
1
2
Item Part #
1
—
2
—
PARTS LIST Description Existing Hose from Tractor to Fan Motor Hydraulic Motor
Aiguard Blockage Prevention System Upgrade Instructions
Item Part #
3
—
2023-03-01
PARTS LIST Description External Check Valve
Page 8
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
8. Hoses may be routed to suit your specific aircart installation. Install
supplied 3/4″ hydraulic hose (Item 1) to the “TRACTOR PRESSURE” port of the
radiator block (Item 2), using adapter (Item 3) to make the connection. Use
model specific connection as per instuctions below to attach the other end of
the hose to the factory pressure line (Item 4) that was removed from the fan
motor.
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
TRACTOR PRESSURE 4
MODEL SPECIFIC CONNECTION
2 3
1
TRACTOR PRESSURE PORT
Remove Plastic Plugs prior to installation
MODEL SPECIFIC CONNECTION
Aircart Models:
with 5/8″ JIC Pressure Hose
Connections
5
Aircart Models: with 3/4″ JIC Pressure Hose Connections
6
Aircart Models:
with 3/4″ ORFS Pressure Hose
All of the hydraulic connections in Step 8 to 12 should only be hand tightened until Connections
all hoses and fittings are installed. Some connections may need to be rotated in order
7
to install other components.
PARTS LIST
PARTS LIST
Item Part #
Description
Item Part #
Description
1
9016
2
—
3
7506
4
—
BPS 3/4″ Hydraulic Hose – 60″
5
7242
“TRACTOR PRESSURE” Port – BP System Manifold
6
7538
Fiting – Elbow – 3/4″ JIC Male – 3/4″ ORB Male
7
7209
Tractor Supply (Pressure) Hydraulic Hose
Fitting – Straight – 5/8″ JIC M – 3/4″ JIC M Fitting – Straight – 3/4″ JIC M – 3/4″ JIC M Fitting – Straight – 3/4″ JIC M – 3/4″ ORFS M
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
Page 9
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
9. Install supplied 3/4″ hydraulic hose (Item 1) to the “TRACTOR RETURN” port
of the radiator block (Item 2) using adapter (Item 3). Use model specific
connection as per instuctions below to attach the other end of the hose to the
factory pressure line (Item 4) that was removed from the fan motor.
RELEASE DATE REV # PART KIT #
TRACTOR RETURN
2 3
2023-03-01 1.0 Varies
Remove Plastic Plugs prior to installation
4
MODEL SPECIFIC CONNECTION
TRACTOR RETURN PORT
1
MODEL SPECIFIC CONNECTION
Aircart Models:
with 5/8″ JIC Return Hose
Connections
5
Aircart Models: with 3/4″ JIC Return Hose Connections
6
Aircart Models:
with 3/4″ ORFS Return Hose
All of the hydraulic connections in Step 8 to 12 should only be hand tightened until Connections
all hoses and fittings are installed. Some connections may need to be rotated in order
7
to install other components.
PARTS LIST
PARTS LIST
Item Part #
Description
Item Part #
Description
1
9016
2
—
3
7506
4
—
BPS 3/4″ Hydraulic Hose – 60″ “TRACTOR RETURN” Port – BP System Manifold Fiting – Elbow – 3/4″ JIC Male – 3/4″ ORB Male Tractor Return Hydraulic Hose
5
7242
6
7538
7
7209
Fitting – Straight – 5/8″ JIC M – 3/4″ JIC M Fitting – Straight – 3/4″ JIC M – 3/4″ JIC M Fitting – Straight – 3/4″ JIC M – 3/4″ ORFS M
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
Page 10
Title
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE 2023-03-01
STEP
10. Install supplied 3/4″ hydraulic hose (Item 1) to the “FAN PRESSURE” port of the radiator block (Item 2) using adapter (Item 3). Use model specific connection as per instuctions below to attach the other end of the hose to the factory fan pressure line/ port (Item 4) coming from the fan motor.
REV # PART KIT #
1.0 Varies
MODEL SPECIFIC CONNECTION
1 3
4 FAN PRESSURE
All of the hydraulic connections in Step 8 to 12 should only be hand tightened until all hoses and fittings are installed. Some connections may need to be rotated in order to install other components.
Remove Plastic Plugs prior to installation
MODEL SPECIFIC CONNECTION
2
FAN
Aircart Models:
PRESSURE with 5/8″ JIC Pressure Hose
PORT
Connections
5
6
Aircart Models: with 3/4″ JIC Pressure Hose Connections
5
Aircart Models:
with 3/4″ ORFS Pressure Hose
Connections
7
5
Item Part #
1
9016
2
—
3
7506
4
—
PARTS LIST Description BPS 3/4″ Hydraulic Hose – 60″ “FAN PRESSURE” Port – BP System Manifold Fiting – Elbow – 3/4″ JIC Male – 3/4″ ORB Male Fan Supply (Pressure) Hydraulic Hose
Item Part #
5
7539
6
7226
7
7588
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
PARTS LIST Description Fitting – Elbow – 3/4″ JIC M – 3/4″ JIC F Fitting –
Straight – 3/4″ JIC M – 5/8″ JIC F Fitting – Straight – 3/4″ JIC M – 3/4″ ORFS
F
Page 11
Title
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE 2023-03-01
STEP
11. Install supplied 3/4″ hydraulic hose (Item 1) to the “FAN RETURN” port of the REV #
radiator block (Item 2) using adapters (Item 3 & 5). Use model specific connection as per instuctions below to attach the other end of the hose to the factory fan return line/
PART KIT #
port (Item 4) coming from the fan motor.
1.0 Varies
MODEL SPECIFIC CONNECTION
FAN RETURN
3
1
5
2
FAN RETURN PORT
All of the hydraulic connections in Step 8 to 12 should only be hand tightened until all hoses and fittings are installed. Some connections may need to be rotated in order to install other components.
Remove Plastic Plugs prior to installation
MODEL SPECIFIC CONNECTION
Aircart Models:
with 5/8″ JIC Return Hose Connections
5
6
Aircart Models: with 3/4″ JIC Return Hose Connections
5
4
Aircart Models: with 3/4″ ORFS Return Hose
Connections
7
5
Item Part #
1
9016
2
—
3
7543
4
—
PARTS LIST Description BPS 3/4″ Hydraulic Hose – 60″ “FAN RETURN” Port – BP System Manifold Fitting – Straight – 3/4″ JIC Male – 3/4″ ORB Male Fan Return Hydraulic Hose
Item Part #
5
7539
6
7226
7
7588
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
PARTS LIST Description Fitting – Elbow – 3/4″ JIC M – 3/4″ JIC F Fitting –
Straight – 3/4″ JIC M – 5/8″ JIC F Fitting – Straight – 3/4″ JIC M – 3/4″ ORFS
F
Page 12
Title
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE 2023-03-01
STEP
12. Install supplied 1/2″ hydraulic hose (Item 1) to the “CASE DRAIN” port of the radiator block (Item 2) using adapters (Item 3 & 4). and to the fan motor case drain line (Item 5). Use model specific connection as per instuctions below to attach the other end of the hose to the factory fan case drain line/port (Item 5) coming from the fan motor.
REV # PART KIT #
1.0 Varies
MODEL
4
SPECIFIC
CONNECTION
3
All of the hydraulic connections in Step 8 to 12 should only be hand tightened until all hoses and fittings are installed. Some connections may need to be rotated in order to install other components.
Remove Plastic Plugs prior to installation
MODEL SPECIFIC CONNECTION
1
Aircart Models:
with 3/8″ JIC Case Drain
9
5
FAN CASE
Hose Connections
10
4
2
DRAIN PORT
Aircart Models:
with 1/2″ JIC Case Drain
4
Hose Connections
6
Aircart Models: with 1/2″ ORFS Case Drain Hose Connections
7 4
8
Item Part #
1
7267
2
—
3
7264
4
7686
5
—
PARTS LIST
Description
Item
BPS 1/2″ Hydraulic Hose – 60″
6
“FAN CASE DRAIN” Port – BP System Manifold
7
Fitting – Straight – 1/2″ JIC Male – 3/8″ ORB Male
8
Fiting – Elbow – 1/2″ JIC M – 1/2″ JIC F
9
Fan Case Drain Hydraulic Hose
10
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
Part # 7263 7265 7266 7294 7293
PARTS LIST Description Fitting – Tee – 1/2″ JIC M – M – F Fitting – Straight –
1/2″ JIC M – 1/2″ ORFS F Fitting – Tee – 1/2″ ORFS M – M – F Fitting –
Straight – 1/2″ JIC M – 3/8″ JIC F Fitting – Tee – 3/8″ ORFS M – M – F
Page 13
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
13. If you have purchased a bypass kit for your BP System, please refer to
the bypass kit owners manual for connection instructions.
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
BYPASS KIT INSTRUCTION MANUAL
PARTS LIST
Item Part #
Description
1
—
—
Aiguard Blockage Prevention System Upgrade Instructions
Item 2 2023-03-01
Part # —
PARTS LIST Description —
Page 14
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
14. Complete the hydraulic installation by ensuring that all connections made
in Step 8 to 13 are tightened. Position/Routing of hydraulic hoses may vary to
suit each specific machine installation. Zip tie hoses to reduce wear and
ensure tidy installation.
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
DO NOT ADJUST VALVES
WARNING:
· Check for contaminants in oil. Dirty oil makes for plugged valves and can
cause issues with over pressurizing the radiator core.
· Start tractor and warm oil prior to starting up fan. This should be done
anytime the fan circuit is started up.
· Engage fan hydraulics at low flow rate and low fan RPM and slowly increase.
· Bleed hydraulic lines of air for stable oil flow.
· Check pressures at radiator gauge. If pressure is higher than normal, steps
must be taken to reduce return line pressure.
· Call Airguard if you have any questions. 1-604-744-0070
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
Page 15
Title STEP
Airguard Blockage Prevention System Upgrade Instructions 15. Start up operating procedure.
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
—– WARNING —–
START UP PROCEDURE:
Start up procedure is critical to reduce pressure spikes.
After you have installed the Airguard Blockage Prevention System it’s critical that you start the Aircart fans very slowly. You’re introducing an air pocket that must be moved slowly to the tractor while you prime the hydraulic lines with oil. This process is a good way to make sure your fittings are sealed and secure.
1. Get your oil warmed to 80-100 deg F. If your oil is cold, the viscosity is
very high and it will not move through the internal components easily. By
warming the oil first, everything will operate as it should.
2. Initiate your fans with 500 Fan RPM at 25% oil flow (or 10% of your max
fan speed). If everything looks good, the pressure is just starting to
register on the Airguard pressure gauge. If all your fittings are holding
their seal, continue to the next step. If your fan is NOT moving, that’s okay.
The oil is circulating. Operate this way for 5 minutes.
NOTE: If there is a pressure spike at this low oil flow rate, there is potential for an air lock. Disconnect the end fitting on the Return Line at the SCV and drain off some oil to release the pressure. Reconnect the end fitting and repeat Step 2.
3. Run 1000 Fan RPM at 45% oil flow (or 35% of your max fan speed). Operate for 5 seconds.
4. Run 2000 Fan RPM at 65% oil flow (or 75% of your max fan speed). Operate for 5 seconds.
5. Run 3500 Fan RPM at 85% oil flow (or 100% of your max fan speed). Operate for 3-5 minutes.
6. Take time to ensure that your conveyor or auger is working properly in conjunction with your Airguard kit. Turn your fan RPM down to 50% oil flow and engage the conveyor/auger. If everything is operating as it should, you have successfully installed your Airguard Blockage Prevention System kit. If there are any questions or concerns about the operations, call your AIRGUARD Sales Representative using contact information found at www.airguardproducts.com/contact or visit us at www.airguardproducts.com/productsupport.
Now you’re ready to operate! Follow the same warm up procedure you do every day and go seed. This is a procedure that we highly recommend at the beginning of each future season, to ensure the continuation of successful operations. It is a critical step in the introduction of new machinery to your farm operation. After the freeze and thaw of seasons we want to eliminate any air pockets or leaks that could slow preparations.
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
Page 16
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
16. There are three ways to mount the Snorkel Kit. It can be mounted directly
to the catwalk (Page 18), to the railing (Page 19), or using the model-
specific Snorkel Mounting Kit (Pages 21-23).
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
CATWALK
RAILING
SNORKEL MOUNTING KIT
THREE SNORKEL MOUNTING OPTIONS
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
Page 17
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
17. Catwalk Installation: Drill two 7/16″ holes in your catwalk (Item 2) 1-3/4″ apart. Using the two bolts (Item 3) and lock nuts (Item 4) provided, bolt the top Snorkel Inlet Assembly (Item 1) directly to the catwalk. Use the bridge clamp (Item 5) to attach 8″ flexible hose (Item 6) to top Snorkel Inlet (Item 1).
REV # PART KIT #
2023-03-01 1.0 Varies
2
1 5
Item Part #
1
7576
2
—-
3
7515
PARTS LIST Description Top Snorkel Inlet Assembly Catwalk Hex Bolt, 10mm x 25mm GRADE 8.8
Aiguard Blockage Prevention System Upgrade Instructions
Item 4 5 6
2023-03-01
Part # 7516 7578 7572
4 3
2
6
PARTS LIST Description Lock Nut, 10mm GRADE 8.8 Bridge Clamp, 8″ Flexible
Snorkel Hose – 8″
Page 18
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
18. Railing Installation: Using two of the bolts (Item 4) and lock nuts (Item 5) pro- REV # vided, hand-tighten the Snorkel Inlet 90deg mount plate (Item 2) and the railing plate PART KIT # (Item 3) around the railing (Item 8). Next, bolt the top Snorkel Inlet assembly (Item 1) to te mount plate (Item 2). Straighten so that the assembly is perpendicular to the railing, then fully tighten. Last, use the bridge clamp (Item 6) to attach 8″ flexible hose (Item 7) to top Snorkel Inlet (Item 1).
2023-03-01 1.0 Varies
4
1
3 4
2
6
5 7
8
Item Part #
1
7576
2
7593
3
7989
4
7991
PARTS LIST Description Top Snorkel Inlet Assembly Snorkel Inlet 90deg Mount Plate Railing Plate HEX BOLT, 10mm x 50mm GRADE 8.8
Aiguard Blockage Prevention System Upgrade Instructions
Item 5 6 7 8
2023-03-01
Part # 7516 7578 7572 —-
PARTS LIST Description Lock Nut, 10mm Bridge Clamp, 8″ Flexible Snorkel Hose – 8″ Railing
Page 19
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
19. Install the brackets (Item 1 & 2) onto Aircart HSS Frame (Item 3) using supplied REV # hardware. Use 12mm x 30mm (Item 4) and 12mm lock nuts (Item 5) for top connec- PART KIT # tion. Use 12mm x 110mm-160mm (Item 6, 7 or 8) and 12mm lock nuts (Item 5) for bottom connection. Bracket is designed to fit HSS Beams 3″-5″ x 3″-10″ in vertical or horizonal mount positions.
2023-01-01 1.0 Varies
4
6 1
7
8
3
2 2
5
3
Item Part #
1
7869
2
7873
3
—
4
7861
PARTS LIST Description Adjustable HSS Backing Plate Adjustable HSS Bracket Assembly Aircart HSS Frame Hex Bolt, 12mm x 30mm
Aiguard Blockage Prevention System Upgrade Instructions
Item 5 6 7 8
2023-03-01
Part # 7669 7862 7863 7864
Tow Behind
PARTS LIST Description Lock Nut, 12mm Hex Bolt, 12mm x 110mm Hex Bolt, 12mm x
130mm Hex Bolt, 12mm x 160mm
Page 20
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
20. Mount outer vertical channel (Item 1) to Mount Bracket (Item 2) using
supplied 12mm x 80mm Bolts (Item 3) and 12mm lock nuts (Item 4).
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
1
3
Item Part #
1
7865
2
—
PARTS LIST Description Outer Vertical Channel Mount Bracket
Aiguard Blockage Prevention System Upgrade Instructions
2
4
Item 3 4
2023-03-01
Part # 7859 7669
PARTS LIST Description Hex Bolt, 12mm x 80mm Lock Nut, 12mm
Page 21
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
21. Attach air intakes (Item 1) to upper vertical channel (Item 2) using supplied 10mm REV # x 25mm Bolts (Item 3) and 10mm lock nuts (Item 4). A maximum of 4 intakes can be PART KIT # mounted. Use bridge clamp (Item 5) to attach 8″ flex hose (Item 6) to air intake (Item 1).
2023-03-01 1.0 Varies
3
1
4
5
6 2
Item Part #
1
7576
2
7868
3
7515
PARTS LIST Description Air Intake Bracket Upper Vertical Channel Hex Bolt, 10mm x 25mm
Aiguard Blockage Prevention System Upgrade Instructions
Item 4 5 6
2023-03-01
Part # 7516 7578 7572
PARTS LIST Description Lock Nut, 10mm Bridge Clamp, 8″ Flexible Snorkel Hose – 8″
Page 22
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
RELEASE DATE
22. Determine desired height of air intakes and secure upper vertical channel (Item 1) REV # to lower vertical channel (Item 2) at that location. Use supplied 12mm x 80mm Bolts PART KIT # (Item 3) and 12mm lock nuts (Item 4).
2023-03-01 1.0 Varies
3 4
2 1
Item Part #
1
7868
2
7865
PARTS LIST Description Upper Vertical Channel Lower Vertical Channel
Aiguard Blockage Prevention System Upgrade Instructions
Item 3 4
2023-03-01
Part # 7859 7669
PARTS LIST Description Hex Bolt, 12mm x 80mm Lock Nut, 12mm
Page 23
Title STEP
Airguard Blockage Prevention System Upgrade Instructions
23. Attach 8″ flex hose (Item 1) to snorkel housing (Item 2) using bridge
clamp (Item 3). Zip tie 8″ flex hoses to reduce wear and ensure tidy
installation.
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
1 3
2
Item Part #
1
7977
2
7578
PARTS LIST Description Snorkel Housing Bridge Clamp, 8″
Aiguard Blockage Prevention System Upgrade Instructions
Item Part #
3
7572
2023-03-01
PARTS LIST Description Flexible Snorkel Hose – 8″
Page 24
Title STEP
Airguard Blockage Prevention System Upgrade Instructions Installation is Completed. Ensure all hydraulic connections and bolts are tightened.
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
COMPLETED INSTALLATION WITH NO SNORKEL
COMPLETED INSTALLATION WITH SNORKELS
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
Page 25
Title STEP
Airguard Blockage Prevention System Upgrade Instructions Troubleshooting and preventative maintenance.
PREVENTATIVE MAINTENANCE 1. Ensure that the startup procedure on page 16 is
performed
every morning before seeding begins. 2. Take extra precautions when seeding in
cold weather. 3. It is recommended that a bypass valve is purchased to allow
for quicker startup.
TROUBLESHOOTING
Trouble
Probable Cause
Fluctuating pressures on pressure High return line pressure gauges and strange noises coming from fan motor.
Faulty quick disconnect couplers
Fan won’t run
Restriction in return line due to small fitting Logic cartridge is contaminated High return line pressure
Quick couplers are disconnected Logic cartridge is contaminated Logic cartridge is faulty Hoses are hooked up incorrectly
Cannot get fan speed up to normal levels
Pressure/flow is too low at tractor
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
Remedy
The logic cartridge on the BP System is set to 750psi. Any value close to or
above that will cause fluctuations and issues with fan speed. Reduce return
line pressure to fix this problem. Replace quick disconnect couplers, inspect
ball valve to ensure proper working order Replace fitting with a larger one
Clean or replace the logic cartridge as needed The logic cartridge on the BP
System is set to 750psi. Any value close to or above that will cause
fluctuations and issues with fan speed. Reduce return line pressure to fix
this problem. Ensure that quick couplers are connected properly
Clean or replace the logic cartridge as needed
Replace the logic cartridge
Consult owner’s manual to see proper installation of hoses Increase
pressure/flow
Page 26
Title STEP
Airguard Blockage Prevention System Upgrade Instructions Frequently asked questions.
RELEASE DATE REV # PART KIT #
2023-03-01 1.0 Varies
FREQUENTLY ASKED QUESTIONS
Q: Why can’t I operate my Blockage Prevention System without warming up my
tractor first? A: Tractor motors and seeding equipment are built to withstand
fast startups; an aluminum radiator is not. On a cold day at 10% oil flow,
your return pressure could be at 500psi on our Blockage Prevention System. If
you were to do a fast startup in cold conditions, you could have a radiator
fail. Pressures could dramatically spike beyond the capacity of our 2400psi
rated aluminum core.
Q: Will the Blockage Prevention System cause dramatic pressure drops in my oil
flow? A: While the BPS will cause a slight pressure drop (approximately 400
RPM or less), the drop in oil flow is negated because of the warm air being
transferred from the oil into the airstream. This allows the internal product
to flow more efficiently. The reason for the slight pressure drop is that the
oil has to pass through the orifices of the radiator, which are smaller than
the hoses used prior to the installation of the Blockage Prevention System.
Q: Does the Blockage Prevention System actually work? A: We can honestly say
that it does. The hotter the oil is in the hydraulic lines, the more heat the
Blockage Prevention System can extract out of that oil. Since the mechanism is
mounted on the face of the fan housing, the fan is pulling air through the
fins of the radiator while the air cart is pressurizing up to operate. The hot
oil, running through the radiator, acts like a furnace and changes the air
temperature on the inside face of the radiator. That air is then pulled into
the air cart stream and is pushed out towards the openers, where the seed is
placed into the furrow. Warmer air holds more moisture. Humidity will stay in
a vapor state when it is drawn in and will be less likely to turn into a
liquid while the air and all the hoses and internal components are physically
warmer. This allows the product to flow through with less resistanc eand
minimizes buildup of dusty fertilizer internally. Seed and fertilizer will be
delivered to the discharge outlets without problems.
Q: What is the purpose of the new bypass valve? A: The new bypass valve
upgrade kit allows you to heat up your oil before engaging your Blockage
Prevention System. You can also choose whether or not to use your BPS in the
heat of the day.
Q: What pressure should the pressure gauge read on the Blockage Prevention
System? A: 300-600psi is an acceptable pressure range when operating. The
gauge reads the pressure of the oil going through the radiator, on the return
side of the fan motor.
Q: Do I need to reset the relief valves on the V2 Blockage Prevention System?
A: No you do not. The valves are preset to 750psi and 850psi. If they do get
changed or altered, please contact Airguard in order to have them reset.
Aiguard Blockage Prevention System Upgrade Instructions
2023-03-01
Page 27
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>