Product Information

Weight 1.2 kg
Energy Efficiency Class F
Safety The installation and operation of this luminaire are subject to

national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage Protection| The electronic components installed in the luminaire are
protected against overvoltage in accordance with DIN EN 61547. To
achieve an additional protection against e.g. transients, etc., we
recommend separate overvoltage protection components. You can find
them on our website at www.bega.com.
Lamp| LED-0607/930
Luminaire Connected Wattage| 10 W
Rated Temperature| 50 – 264.2 K3
Ambient Temperature| Not specified
Colour Temperature| 3000 K
Colour Rendering Index| Ra > 90
Module Luminous Flux| 940 lm
Luminaire Luminous Flux| 495 lm
Luminaire Luminous Efficiency| 49.5 lm/W

Product Usage Instructions

  • Installation
    • LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
    • Lead the mains supply cable through the cable entry of the luminaire base.
    • Fix the luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
    • Be sure to use the gasket rings supplied.
    • Establish earth conductor connection and make the electrical connection to the terminals.
    • Advice: Expansion of glass and metal is different. Glass must be allowed to expand. Place glass into the luminaire base and fix set screws handtight. After tightening the set screws, loosen them for half a turn to allow the glass to move.
  • Replacing the LED module
    • The designation of the LED module is noted on a label in the luminaire.
    • Replacement modules from BEGA correspond to the specified designation.
    • The replacement should be carried out by a qualified person.
    • Switch off the power supply to the system.

Dimensions

BEGA-50264-2-Wall-Luminaire-for-Indoor-Use-fig-1

Instructions for use

Application

  • Shielded wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt with metal shield, for many lighting tasks.
  • The light emits upwards and downwards.

Product Description

  • Metal housing, finish colour white Hand-blown opal glass, satin matt
  • Metal shield, stainless steel finish 2 elongated fixing holes
  • Width:  4.5 mm · 185 mm spacing 1 cable entry for through-wiring for mains cable
  • Connecting terminals 2.5@
  • Earth conductor connection
  • LED-Module for mains voltage: 220-230 V 50/60 Hz
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class: I
  • : Safety mark
  • CE: Conformity mark
  • Weight: 1.2 kg
  • This product contains light sources of energy efficiency class(es) F

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Specification

Lamp

  • Luminaire connected wattage: 10 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 35 °C

50 264.2 K3

  • Module designation LED-0607/930
  • Colour temperature 3000 K
  • Colour rendering index Ra > 90
  • Module luminous flux 940 lm
  • Luminaire luminous flux 495 lm
  • Luminaire luminous efficiency 49,5 lm / W

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Lead the mains supply cable through the cable entry of the luminaire base.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied.
  • Establish earth conductor connection and make the electrical connection to the terminals.

Advice

  • Expansion of glass and metal is different.
  • Glass must be allowed to expand.
  • Place glass into the luminaire base and fix set screws handtight.
  • After tightening the set screws loosen them for half a turn to allow the glass to move.

Maintenance

Cleaning/ Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified electrician or a comparably qualified person using standard tools.
  • Disconnect the electrical installation.
  • Open the luminaire.
  • Please follow the installation instructions for the
  • LED module.
  • Close the luminaire.

Spares

  • Spare glass: 11 003 223 .0M 1RG
  • LED module 3000 K: LED-0607/930