ALPHA Ezy-i Water Heater Instruction Manual

June 10, 2024
Alpha

ALPHA Ezy-i Water Heater Instruction Manual

PARTS DESCRIPTION

  1. Front Cover
  2. Indicator Lights
  3. Temperature Control Knob
  4. Stop Valve
  5. Water Filter
  6. Water Regulator
  7. Handsomer
  8. Flexible Hose
  9. Rail Supports
  10. Sliding Rail
  11. Shower Holder
  12. Heater Base
  13. Rear Cable Entry
  14. Side Cable Entry
  15. Built-in ELSD
  16. Electronics Control Unit
  17. Flow Switch Assembly
  18. Water INLET Connection
  19. Cable Clamp
  20. Terminal Block
  21. Thermal Cut-Out
  22. Heating Element
  23. Heater Tank
  24. Triac
  25. TEST / RESET PCB
  26. Heater Base Mounting Holes (4 Holes)
  27. Water OUTLET Connection

The shower accessories may look different from the picture shown in the manual as it is subjected to requirement from different countries.

  1. Heater Cover
  2. Indicator Lights
  3. Temperature Control Knob
  4. Stop Valve
  5. Water Filter
  6. Water Regulator
  7. Handsomer
  8. Flexible Hose
  9. Rail Supports
  10. Sliding Rail
  11. Shower Holder
  12. Heater Base
  13. Rear Cable Entry
  14. Side Cable Entry
  15. Built-in ELSD
  16. Pump Assembly
  17. Electronics Control Unit
  18. Flow Switch Assembly
  19. Water INLET Connection
  20. Cable Clamp
  21. Terminal Block
  22. Termal Cut-Out
  23. Heating Element
  24. Heater Tank
  25. Triac
  26. TEST / RESET PCB
  27. Heater Base Mounting Holes (4 Holes)
  28. Water OUTLET Connection

The shower accessories may look different from the picture shown in the manual as it is subjected to requirement from different countries.

GENERAL INFORMATION

ELECTRICAL

CAUTION:
THIS APPLIANCE MUST BE EARTHED.

  1. All wiring MUST conform to local regulations. If in doubt, always consult a qualified electrician.
  2. Installation must be carried out by a qualified electrician.
  3. The heater must be permanently connected to the electricity supply through a double pole linked switch having a contact separation of at least 3mm in all poles incorporated in the circuit, and out of reach from the person using the shower.
  4. The use of plug and socket is not allowed.
  5. Correct size of wire conductor corresponding to different electrical loading shall be used.
    Power

(kW)

| Amperes| Recommended Conductor Size (csa)| Fuse/MCB (A)| ON/OFFSwitch (A)
---|---|---|---|---
(A)| mm2| Comduit Cable| Flexible Cable
3.5| 16.0| 4.0| 7/0.85mm| 56/0.30| 20| 20
4.5| 20.5| 4.0| 7/0.85mm| 56/0.30| 25| 25
5.5| 25.0| 4.0| 7/0.85mm| 56/0.30| 32| 32
6.0| 27.3| 4.0| 7/0.85mm| 56/0.30| 32| 32
6.5| 29.6| 4.0| 7/0.85mm| 56/0.30| 40| 40
7.5| 34.1| 6.0| 7/1.04mm| 84/0.30| 40| 40
8.0| 36.4| 6.0| 7/1.04mm| 84/0.30| 40| 40
3.5| 15.2| 4.0| 7/0.85mm| 56/0.30| 20| 20
5.5| 24.0| 4.0| 7/0.85mm| 56/0.30| 32| 32
6.6| 28.7| 4.0| 7/0.85mm| 56/0.30| 32| 32
8.8| 38.3| 6.0| 7/1.04mm| 84/0.30| 45| 45
3.6| 15.0| 4.0| 7/0.85mm| 56/0.30| 20| 20
4.2| 17.5| 4.0| 7/0.85mm| 56/0.30| 20| 20
7.1| 29.6| 4.0| 7/0.85mm| 56/0.30| 40| 40
9.5| 39.6| 6.0| 7/1.04mm| 84/0.30| 45| 45
6. A typical electrical wiring connection is shown in diagram 1.

General Wiring Connection

  • Amperes Rating refer Electrical Loading Table
  • Conductor size refer Electrical Loading Table

**General Plumbing Connection


**

Model: Ezio – Water supply from house hold gravity water storage tank.
Model: Ezy-E – Water supply direct from mains.

WATER
  1. The heater works at a minimum water flow rate of 3 litres/min. Note that for heater model without built-in pump an incoming water with consistently flow rate of 5 liters/min and above would excel its performance.
  2. A typical plumbing connection is shown in diagram 2.
SAFETY

Note: An approved type of Residual Current Device (RCD) of 10mA sensitivity shall be installed in conjunction with the heater.

  1. The built-in Earth Leakage Sensing Device (ELSD) will cut off the power supply to the heater in the event of current leakage of as low as 15mA.
  2. The heater operates when there is sufficient water to trigger the Flow Switch.
  3. The Thermal Cut-out would automatically cut-off the power supply if there is abnormal rise in the water temperature during shower.
  4. Heater casing designed to a high degree of protection (IP25), it prevents water from entering into the heater during shower.

IMPORTANT NOTE:

  1. This heater is tested suitable for use in the shower cubicles. However, do not install the heater unit where is consistent spray directly over the unit.
  2. If the heaters ELSD trips during normal operation, switch off the mains supply and contact the service centre for repair(s).
  3. In the event if the heater malfunctioned, never attempt to repair the unit by yourself.
  4. The outlet point of this heater, hose and handshower act as a vent. They must not be blocked, obstructed or modified in any way. Fittings not recommended by manufacturer must not be connected. The use of unapproved accessories may not only affect its performance and safety of the user but also voids its warranty.
  5. If there is a sudden reduction of incoming water, the shower temperature will increase. This does not indicate the fault of the heater. Adjust the Temperature Control Knob (to reduce heating power) or Water Regulator (to increase flow) in order to get the desired shower temperature.
  6. Always test the water spray temperature with your hand before stepping into the shower.
  7. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  8. Children should be supervised to ensure that they do not play with the appliance.

INSTALLATION PROCEDURES

IMPORTANT:

  • All plumbing work shall be completed before proceeding to electrical wiring connection.
  • Metallic / Chromed hose and conductive control valve shall not be used (in Malaysia only- Malaysian government’s regulations. Optional for others).
  • Heater outlet shall not be connected to any tap or fittings not recommended by manufacturer.
  • The heater unit must be installed on solid wall to avoid the possibility of distorting the unit.
  • Inlet and Outlet connections of the heater must not be reversed.

Decide the mounting position:
a) Turn off the water source. lift up
b) Remove screw at the bottom of the heater. from h
c) Remove Heater Cover by lifting the bottom upward.
d) Mark out 4 mounting points on the wall.

Note:
It is recommended that mount the bottom of the heater be 1.50 meters /5 feet above the floor of the bathroom. However the height of the installation level is at the discretion of the user.

Mounting of the heater:
a) Drill the 4 holes with 5.0mm diameter drill bit.
b) Put in the wall plugs and install the heater to the wall with screws provided.

Shower Accessories Installation:
a) Fix the Shower Holder and Rail Supports (Top and Bottom) on to the Sliding Rail.
b) Mark the positions of the 2 holes of the Rail uppers – be sure that the top portion is in Slic level or not higher than the top of the heater. Shower
c) Drill the holes and mount the shower accesories with wall plugs and screws provided. Insert the Rail Support Caps on to the Rail Supports.

Connection of heater Inlet and Outlet:
a) Connect Stop Valve to heater Inlet with | use of the rubber seal provided. \
b) Connect incoming water supply to Stop Valve. If necessary make use of the sealing tape to prevent water leaking
c) Connect Flexible Hose to heater Outlet. (Do not connect the other end of flexible hose to handsomer at this stage).
d) Turn on the water supply to drain out all the plumbing dirt and to fill up the heater tank. (This step will prevent damage to Heating Element.)
e) Connect the other end of flexible hose to handsomer – be sure to put in the Filter Mesh Washer in order to prevent dirt from entering the handsomer.

Note:

  • Do not apply excessive force to tighten any of the connections.
  • Excessive force may cause damage to the connector.
  • Do not bend the Flexible Hose or install any accessories which can block the water flow at heater outlet.

Electrical Connection:

CAUTION:
Make sure the electrical mains is off before carrying on the electrical work.

a) Insert electrical cable through the rubber grommet for side entry or wall embedded entry.
b) Connect cable to Terminal Block and fully tighten them as follows:
RED or BROWN . LIVE (L)
BLACK or BLUE . NEUTRAL (N)
GREEN/YELLOW or
YELLOW/GREEN …….. EARTH (8)
c) Replace the Heater Cover:

  1. To ensure correct position, turn the Electronic Control Unit to the off position (as shown in picture).
  2. Install the heater cover and ensure that the Temperature Control Knob is aligned (point to ‘OFF’ to its control unit accordingly.
  3. Secure the screw as shown.

Test Run Of Heater:
a) Turn on Stop Valve.
c) Turn on the Temperature Control Knob. The ‘HEATER’ indicator will light up. The water should be warm in a few seconds.
d) The water would get warmer as the Temperature Control Knob is turned clockwise.
e) Check the built-in ELSD as follow:

  • Press ‘TEST’ button: unit should trip and cut off power supply.
  • Press ‘RESET’ button: unit should resume normal function. If the above mentioned steps prevail, the ELSD is functioning normally.

OPERATING PROCEDURES

  1. Switch on the heater switch outside the bathroom. The ‘ELSD’ indicator would light up.
  2. Turn on the Stop Valve. Adjust the Water Regulator for suitable water shower volume.
  3. Tum on Temperature Control Knob. The ‘HEATER’ indicator would light up. The shower water would get warmer as the knob is turned clockwise from ‘ON’ to ‘MAX’.
  4. Normal cold water can be selected by setting the Temperature Control Knob to ‘OFF’ position.
  5. Switch off the heater switch when not in use.

Note:

  • The shower water may not be hot enough even at ‘MAX’ in areas whereby the water ressure is exceptionally high and cold. This can be remedied by reducing the water new ot replacing the unit with one that is of higher power (if it is approved by relevant authorities).

  • The built-in Pump can be independently controlled by using the Pump Control Knob. In low pressure areas (below 15 p.s.i.), adjust pump speed to obtain desired spray of water. If water pressure is high (over 15 p.s.i.), turn “OFF” the Pump Control Knob to achieve hotter shower. (Model Ezy-i)

  • The Pump Activator is specially designed for low pressure areas whereby the water
    pressure is too weak to trigger the Bi shower Pump. Just press the Pump Activator Button and the Shower Pump will spring into action. (Model Ezy-i)

  • Itis recommended that the pump be operated at intervals of 30 minutes with 30 minutes rest in between. (Model Ezy-i)

CUSTOMER GUIDANCE:

a) Connection of heater INLET b) Connection of heater OUTLET:

Connect stop Valve to INETI
| Connect Flexible Hose to OUTLET

c) Temperature Control Knob:| d) Built-in ELSD:
Temperature Control Knob
| Check the ELSD at least once a month as follow:
 Turn on electric and water supply to the heater.

  • Press TEST button: Heater would trip and power go off.
  • Press RESET button: Heater power would resume. Contact service centre for repair if there is malfunction

e) Stop Valve:| f) Water Regulator:
| Adjust clockwise to reduce water inflow if shower temperature not hotenough even at ‘MAX’ power setting

MAINTENANCE

DO NOT USE THINNER, ALCOHOL OR PETROL

You may clean the heater with a damp cloth and mild detergent but do not use thinner, alcohol, petrol or any other corrosive solutions.

CLEAN FILTER REGULARLY

The filter should be cleaned whenever there is a sign of inlet water blockage.

a) Stop Valve
Remove Filter Mesh Cap. Pull out Filter Mesh and flush it with water to remove any trapped sediments. Slot it back to its original position before securing it with the Filter Mesh Cap.

b) Hand shower
Disconnect the handsomer from the hose. Remove Filter Mesh Washer and flush it with water to remove any trapped sediments. Re-connect the handsomer back to the hose.

Note:

  • Make sure to turn off the incoming water supply before the operation.
  • This has to be done more regularly in area where the inlet water supply is dirty.
  • The design of the stop valve may look different from the picture shown in the manual as it is subjected to requirement from different countries.

GENERAL INFORMATION

SPECIFICATION
Heater Power Rating Ezy-E 3.60kW 240V- 50Hz
Ezy-i 3.64kW 240V – 50Hz
Others Power Rating Refer to Electrical Loading Table for reference
Water Connection 0 15.0mm (1/2″ BSP)
Operating Condition Open Outlet
Protection Against Electric Shock Class I
Water Temperature Control Electronics
Degree Of Protection IP25
Minimum Flow Rate 3 liters / minute
Minimum Pressure 20kPa (0.2 bar / 2.9 psi)
Maximum Inlet Pressure 0.38MPa (3.8 bar / 55psi)
Heater Dimension 340mm (L) x 210mm (W) x 95mm (H)
Heater Nett Weight Ezy-E 1.5kg
Ezy-i 1.8kg
SCHEMATIC WIRING DIAGRAM
  • All pictures shown are for illustration purpose only. Actual product may vary due to product enhancement.

  • All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, without prior written permission from Alpha Electric Co. Sdn. Bhd.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Alpha User Manuals

Related Manuals