PPI UniRec Multi Channel Temperature Data Logger Cum Recorder
Product Information
The UniRec Process Data Recorder is a device that records and stores data from various devices. It has multiple configuration parameters that can be set to suit the user’s requirements. The device can be connected to a pen drive for data transfer and also has supervisory configuration settings.
Operator Parameters
The Operator Parameters allow users to select options for operation on a pen drive. The available options are None, Copy (New), Re-copy (Old), Read Chan Names, and Recover. The default value is None. Users can also select the ‘Start’ and ‘Stop’ commands for batch recording if the batch recording is selected.
Supervisory Configuration
The Supervisory Configuration allows users to set the boiler temperature and select the desired supervisory or operator page. Users can also set a passcode and configure the device settings.
Device Configuration
The Device Configuration allows users to erase all stored records, set the channel update time in auto-scan mode, and set the device identification number. The default value for erasing all stored records is No, the default value for scan rate is 3 seconds, and the default value for recorder ID is 1.
Relay Configuration
The Relay Configuration allows users to set the logic for Relay-1 and Relay-2. The default value for both relays is Normal.
Recorder Configuration
The Recorder Configuration allows users to set the normal recording interval and zoom recording interval. Users can also enable or disable record generation on the alarm status toggle, select the recording mode, and set the time interval for batch recording. Users can select the ‘Start’ and ‘Stop’ commands for batch recording if the batch recording is selected. The default value for a normal recording interval is 0:02 and for zoom, the recording interval is 0:01. The default value for record generation on the alarm status toggle is Enable and for recording mode is Continuous. The default value for batch time is 1.00.
Product Usage Instructions
1. To select an option for operation on a pen drive, go to Operator Parameters and choose from None, Copy (New), Re-copy (Old), Read Chan Names, and Recover.
2. To set the ‘Start’ and ‘Stop’ commands for batch recording, go to Operator Parameters and choose Yes or No.
3. To set the boiler temperature and select the supervisory or operator page, go to Supervisory Configuration and enter the passcode. Then select the desired page.
4. To erase all stored records, set the channel update time in auto-scan mode, and set the device identification number, go to Device Configuration and choose the desired settings.
5. To set the logic for Relay-1 and Relay-2, go to Relay Configuration and choose Normal or Reverse.
6. To set the normal recording interval, zoom recording interval, record generation on alarm status toggle, recording mode, and time interval for batch recording, go to Recorder Configuration and choose the desired settings. Select Yes or No for the ‘Start’ and ‘Stop’ commands for batch recording.
Please refer to the product manual for more details on operation and application.
This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net
OPERATOR PARAMETERS
SUPERVISORY CONFIGURATION
DEVICE CONFIGURATION
The list for the Device Type is subject to change (grow) as the UniRec is upgraded to support more models from the PPI range of existing / future products.
RELAY CONFIGURATION
RECORDER CONFIGURATION
RTC SETTING
UTILITIES
FRONT PANEL LAYOUT
Keys Operation
PV Error Indications
Error Message Cause
- Over Range: Process Value above Max. Range
- Process Value above Max. Range: Process Value below Min. Range
- Sensor Open: Thermocouple / RTD broken
- Com. Fail: Communication Link with Device broken
ELECTRICAL CONNECTIONS
WIRING CONNECTION