PPI UniLog Pro Universal Process Data Recorder PC User Manual

June 11, 2024
PPI

Unclogs Pro / Unclogs Pro Plus with AIS
Universal Process Data Recorder PC Software Version
Operation Manual

UniLog Pro Universal Process Data Recorder PC

OPERATOR PARAMETERS

Parameters| Settings (Default Value)
‘Start’ Command for Batch Recording (Available if Batch Recording is selected)
| No
Yes
‘Stop’ Command for Batch Recording (Available if Batch Recording is selected)
| No
Yes

SUPERVISORY CONFIGURATION

PPI UniLog Pro Universal Process Data Recorder PC -
fig

Note: AII the other Parameters are under SUPERVISORY CONFIGURATION

ALARM SETTING

Parameters| Settings(Default Value)
Channel Name for Alarm Settings
| User defined or default names for channel-1 to channel-8 /  16 (Default : NA)
Select Alarm
| AU , AL2, AL3, AL4
(The actual available options depends on the numbers of  Alarms set per channel on Alarm configuration page)
Alarm Type
| None
Process Low
Process High
(Default : None)
Alarm Setpoint
| Min. to Max. of selected input type range (Default : 0)
Alarm Hysteresis
| 1 to 3000 or 0.1 to 3000.0
(Default : 2 or 2.0)
Alarm Inhibit
| No
Yes
(Default : No)
DEVICE CONFIGURATION

Parameters| Settings (Default Value)
Channel Update Time in Auto Scan Mode
| 1 Sec. to 99 Sec. (Default: 3 Sec.)
Device Identification Number
| 1 to127 (Default : 1)
Select Total Numbers of Channels
| 8
16
(Default : 16)
Erase All Stored Records
| No
Yes
(Default : No)
CHANNEL CONFIGURATION

Parameters| Settings (Default Value)
Select Channel Name
| User defined or default names for channel-1 to channel – 8 /  16 (Default : NA)
Skip Channel for Display
| No
Yes
(Default : Yes)
Signal Input Type
| Refer Table 2
(Default : Type K (Cr-Al)
Display Resolution for Measured PV
| 1 Unit
0.1 Unit
0.01 Unit
0.001 Unit
(Default : 0.1 Unit)
Display Units for Measured PV
| Refer Table 1 (Default : °C)
Range Low
| -19999 to 30000 Counts with Selected Resolution (Default : 0.0)
Range High
| -19999 to 30000 Counts with Selected Resolution
(Default : 100.0)
Apply Lower Clip on Displayed PV
| Disable
Enable
(Default : Disable)
Preset Lower Clip Level
| -19999 to 30000
(Default : 0)
Apply Upper Clip on Displayed PV
| Disable
Enable
(Default : Disable)
Preset Upper Clip Level
| -19999 to 30000 (Default : 100.0)
Zero Offset
| -1999 / 3000 or
-1999.9 / 3000.0
(Default : 0)
ALARM CONFIGURATION

Parameters| Settings (Default Value)
Alarms Per Channel
| 1 to 4 (Default : 4)
Relay-1 Logic
| Normal
Reverse
(Default : Normal)
Relay-2 Logic
| Normal
Reverse
(Default : Normal)
RECORDER CONFIGURATION

Parameters| Settings (Default Value)
Normal Recording Interval
| 0:00:00 (H:MM:SS) to 2:30:00 (H:MM:SS)
(Default : 0:00:30)
Zoom Recording Interval
| 0:00:00 (H:MM:SS) to 2:30:00 (H:MM:SS)
(Default : 0:00:01)
Record Generation on Alarm Status Toggle
| Disable
Enable
(Default : Enable)
Select Recording Mode
| Continuous Batch (Default : Continuous)
Time Interval for Batch Recording
| 0:01 (HH:MM) to 250:00 (HHH:MM)
(Default : 1:00)
RTC SETTING

Parameters| Settings
Set Clock Time (HH:MM)
| 0.0 to 23:59
Set Calendar Date
| 1 to 31
Set Calendar Month
| 1 to 12
Set Calendar Year
| 2000 to 2099
UTILITIES

Parameters| Settings
Master Lock Enable Disable
| No
Yes
UIM Default
| No
Yes
CIM Default
| No
Yes
Make CIM & UIM Compatible
| No
Yes

  • For Uni Log Pro Plus with more Than One AIS Only

TABLE-1

Option| Description
°C| Degree Centigrade
°F| Degree Fahrenheit
(none)| No Unit (Blank)
°K| Degree Kelvin
EU| Engineering Units
| Percentage
Pa| Pascals
Mpa| Pascals
kPa| Pascal’s
bar| Bar
mbar| Millie bar
psi| PSI
kg/sq.cm| kg/cm2
mmH2O| mm water gauge
inH2O| Inches water gauge
mmHg| mm mercury
Torr| Torr
litre/hr| Litres per hour
litre/min| Litres per minute
%RH| % Relative Humidity
%02| % Oxygen
%002| % Carbon di-oxide
%CP| % Carbon Potential
V| Volts
A| Amps
mA| Millie Amps
mV| Millis Volts
ohm| Ohms
ppm| Parts per million
rpm| Revolutions per minute
music| Millie seconds
Sec| Seconds
min| Minutes
hrs| Hours
PH| PH
%PH| %PH
miles/hr| Miles per hour
mg| Millie grams
g| Grams
kg| Kilo grams
TABLE- 2

Option| Range (Min. to Max.)| Resolution
J Type T/C| 0 to +960°C / +32 to +1760°F| Fixed 1°C / 1°F
K Type T/C| -200 to +1376°C / -328 to +2508°F
T Type T/C| -200 to +385°C / -328 to +728°F
R Type T/C| 0 to +1771°C / +32.0 to +3219°F
S Type T/C| 0 to +1768°C / +32 to +3214°F
B Type T/C| 0 to +1826°C / +32.0 to +3218°F
N Type T/C| 0 to +1314.0°C / +32 to +2397.0°F
| Reserved for customer specific Thermocouple type not listed above.
RTD Pt100| -199 to +600°C / -328 to +1112°F or -199.9 to 600.0°C/ -328.0 to 1112.0°F| User settable
1°C/ 1°F or 0.1°C / 0.1°F
0 to 20mA DC| -19999 to +30000 units| User settable 1 / 0.1 / 0.01/ 0.001 units
4 to 20mA DC
0 to 50mV DC
0 to 200mV DC
0 to 1.25V DC
0 to 5.0V DC
0 to 10.0V DC
1 to 5.0V DC

ID SETTING FOR MORE THAN 1 AIS
Applicable only for UNILOG PRO PLUS

PPI UniLog Pro Universal Process Data Recorder PC - fig
2

FRONT PANEL LAYOUT

PPI UniLog Pro Universal Process Data Recorder PC - fig
3

Symbol Key Function
PAGE Press to enter or exit set-up mode.
DOWN Press to decrease the parameter value. Pressing once decreases the

value by one count; holding pressed speeds up the change.
| UP| Press to increase the parameter value. Pressing once increases the value by one count; holding pressed speeds up the change.
| ENTER| Press to store the set parameter value and to scroll to the next parameter on the PAGE.

PV Error Indications

Error Message Cause
Over Range Process Value above Max. Range
Under Range Process Value below Min. Range
Sensor Open Thermocouple / RTD broken
Com. Fail Communication Link with CI M broken

ELECTRICAL CONNECTIONS

USER INTERFACE MODULE (UIM)

PPI UniLog Pro Universal Process Data Recorder PC - fig
4

COMMUNICATION PORT FOR INTERFACING WITH AIS(S)

Applicable only for UNILOG PRO PLUS

PPI UniLog Pro Universal Process Data Recorder PC - fig
5

ANALOG INPUT MODULE CONNECTIONS

AIS-8UM

PPI UniLog Pro Universal Process Data Recorder PC - fig
6

AIS-16UM

PPI UniLog Pro Universal Process Data Recorder PC - fig
7

101, Diamond Industrial Estate, Navghar,
Vasai Road (E), Dist. Palghar – 401 210.
Sales : 8208199048 / 8208141446
Support : 07498799226 / 08767395333
E: sales@ppiindia.net, support@ppiindia.net
Jan 2022

Documents / Resources

| PPI UniLog Pro Universal Process Data Recorder PC [pdf] User Manual
UniLog Pro Universal Process Data Recorder PC, UniLog Pro, Universal Process Data Recorder PC, Process Data Recorder PC, Data Recorder PC, Recorder PC, PC
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PPI User Manuals

Related Manuals