OPERATOR PARAMETERS
Parameters| Settings (Default Value)
‘Start’ Command for Batch Recording (Available if Batch Recording is selected)
| No
Yes
‘Stop’ Command for Batch Recording (Available if Batch Recording is selected)
| No
Yes
SUPERVISORY CONFIGURATION
Note: AII the other Parameters are under SUPERVISORY CONFIGURATION
ALARM SETTING
Parameters| Settings(Default Value)
Channel Name for Alarm Settings
| User defined or default names for channel-1 to channel-8 / 16 (Default :
NA)
Select Alarm
| AU , AL2, AL3, AL4
(The actual available options depends on the numbers of Alarms set per
channel on Alarm configuration page)
Alarm Type
| None
Process Low
Process High
(Default : None)
Alarm Setpoint
| Min. to Max. of selected input type range (Default : 0)
Alarm Hysteresis
| 1 to 3000 or 0.1 to 3000.0
(Default : 2 or 2.0)
Alarm Inhibit
| No
Yes
(Default : No)
DEVICE CONFIGURATION
Parameters| Settings (Default Value)
Channel Update Time in Auto Scan Mode
| 1 Sec. to 99 Sec. (Default: 3 Sec.)
Device Identification Number
| 1 to127 (Default : 1)
Select Total Numbers of Channels
| 8
16
(Default : 16)
Erase All Stored Records
| No
Yes
(Default : No)
CHANNEL CONFIGURATION
Parameters| Settings (Default Value)
Select Channel Name
| User defined or default names for channel-1 to channel – 8 / 16 (Default :
NA)
Skip Channel for Display
| No
Yes
(Default : Yes)
Signal Input Type
| Refer Table 2
(Default : Type K (Cr-Al)
Display Resolution for Measured PV
| 1 Unit
0.1 Unit
0.01 Unit
0.001 Unit
(Default : 0.1 Unit)
Display Units for Measured PV
| Refer Table 1 (Default : °C)
Range Low
| -19999 to 30000 Counts with Selected Resolution (Default : 0.0)
Range High
| -19999 to 30000 Counts with Selected Resolution
(Default : 100.0)
Apply Lower Clip on Displayed PV
| Disable
Enable
(Default : Disable)
Preset Lower Clip Level
| -19999 to 30000
(Default : 0)
Apply Upper Clip on Displayed PV
| Disable
Enable
(Default : Disable)
Preset Upper Clip Level
| -19999 to 30000 (Default : 100.0)
Zero Offset
| -1999 / 3000 or
-1999.9 / 3000.0
(Default : 0)
ALARM CONFIGURATION
Parameters| Settings (Default Value)
Alarms Per Channel
| 1 to 4 (Default : 4)
Relay-1 Logic
| Normal
Reverse
(Default : Normal)
Relay-2 Logic
| Normal
Reverse
(Default : Normal)
RECORDER CONFIGURATION
Parameters| Settings (Default Value)
Normal Recording Interval
| 0:00:00 (H:MM:SS) to 2:30:00 (H:MM:SS)
(Default : 0:00:30)
Zoom Recording Interval
| 0:00:00 (H:MM:SS) to 2:30:00 (H:MM:SS)
(Default : 0:00:01)
Record Generation on Alarm Status Toggle
| Disable
Enable
(Default : Enable)
Select Recording Mode
| Continuous Batch (Default : Continuous)
Time Interval for Batch Recording
| 0:01 (HH:MM) to 250:00 (HHH:MM)
(Default : 1:00)
RTC SETTING
Parameters| Settings
Set Clock Time (HH:MM)
| 0.0 to 23:59
Set Calendar Date
| 1 to 31
Set Calendar Month
| 1 to 12
Set Calendar Year
| 2000 to 2099
UTILITIES
Parameters| Settings
Master Lock Enable Disable
| No
Yes
UIM Default
| No
Yes
CIM Default
| No
Yes
Make CIM & UIM Compatible
| No
Yes
- For Uni Log Pro Plus with more Than One AIS Only
TABLE-1
Option| Description
°C| Degree Centigrade
°F| Degree Fahrenheit
(none)| No Unit (Blank)
°K| Degree Kelvin
EU| Engineering Units
| Percentage
Pa| Pascals
Mpa| Pascals
kPa| Pascal’s
bar| Bar
mbar| Millie bar
psi| PSI
kg/sq.cm| kg/cm2
mmH2O| mm water gauge
inH2O| Inches water gauge
mmHg| mm mercury
Torr| Torr
litre/hr| Litres per hour
litre/min| Litres per minute
%RH| % Relative Humidity
%02| % Oxygen
%002| % Carbon di-oxide
%CP| % Carbon Potential
V| Volts
A| Amps
mA| Millie Amps
mV| Millis Volts
ohm| Ohms
ppm| Parts per million
rpm| Revolutions per minute
music| Millie seconds
Sec| Seconds
min| Minutes
hrs| Hours
PH| PH
%PH| %PH
miles/hr| Miles per hour
mg| Millie grams
g| Grams
kg| Kilo grams
TABLE- 2
Option| Range (Min. to Max.)| Resolution
J Type T/C| 0 to +960°C / +32 to +1760°F| Fixed 1°C / 1°F
K Type T/C| -200 to +1376°C / -328 to +2508°F
T Type T/C| -200 to +385°C / -328 to +728°F
R Type T/C| 0 to +1771°C / +32.0 to +3219°F
S Type T/C| 0 to +1768°C / +32 to +3214°F
B Type T/C| 0 to +1826°C / +32.0 to +3218°F
N Type T/C| 0 to +1314.0°C / +32 to +2397.0°F
| Reserved for customer specific Thermocouple type not listed above.
RTD Pt100| -199 to +600°C / -328 to +1112°F or -199.9 to 600.0°C/ -328.0 to
1112.0°F| User settable
1°C/ 1°F or 0.1°C / 0.1°F
0 to 20mA DC| -19999 to +30000 units| User settable 1 / 0.1 / 0.01/ 0.001
units
4 to 20mA DC
0 to 50mV DC
0 to 200mV DC
0 to 1.25V DC
0 to 5.0V DC
0 to 10.0V DC
1 to 5.0V DC
ID SETTING FOR MORE THAN 1 AIS
Applicable only for UNILOG PRO PLUS
FRONT PANEL LAYOUT
Symbol | Key | Function |
---|---|---|
PAGE | Press to enter or exit set-up mode. | |
DOWN | Press to decrease the parameter value. Pressing once decreases the |
value by one count; holding pressed speeds up the change.
| UP| Press to increase the parameter value. Pressing once increases the value
by one count; holding pressed speeds up the change.
| ENTER| Press to store the set parameter value and to scroll to the next
parameter on the PAGE.
PV Error Indications
Error Message | Cause |
---|---|
Over Range | Process Value above Max. Range |
Under Range | Process Value below Min. Range |
Sensor Open | Thermocouple / RTD broken |
Com. Fail | Communication Link with CI M broken |
ELECTRICAL CONNECTIONS
USER INTERFACE MODULE (UIM)
COMMUNICATION PORT FOR INTERFACING WITH AIS(S)
Applicable only for UNILOG PRO PLUS
ANALOG INPUT MODULE CONNECTIONS
AIS-8UM
AIS-16UM
101, Diamond Industrial Estate, Navghar,
Vasai Road (E), Dist. Palghar – 401 210.
Sales : 8208199048 / 8208141446
Support : 07498799226 / 08767395333
E: sales@ppiindia.net,
support@ppiindia.net
Jan 2022
Documents / Resources