PPI HumiTherm-iS Temperature Humidity Indicator User Manual
- June 11, 2024
- PPI
Table of Contents
- PPI HumiTherm-iS Temperature Humidity Indicator
- HumiTherm-iS
- Product Information
- Product Usage Instructions
- OPERATOR PAGE AND PARAMETERS
- RECORDER (RETRANSMISSION) PARAMETERS
- FRONT PANEL LAYOUT
- ELECTRICAL CONNECTIONS
- JUMPER SETTINGS
- ENCLOSURE ASSEMBLY
- MOUNTING DETAILS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PPI HumiTherm-iS Temperature Humidity Indicator
HumiTherm-iS
Advanced ‘Temperature + Humidity’ Indicator with Control & Alarms
Product Information
The HumiTherm-iS is an advanced temperature and humidity indicator with control and alarms. It provides temperature and humidity control setpoints, as well as temperature and humidity alarm setpoints with low and high limits. The device also features ON-OFF control parameters, alarm parameters, input configuration parameters, and supervisory parameters. It has a range of input types including RTD, 0-20mA, 4-20mA, 0-50mV, 0-200mV, 0-1.25V, 0-5V, 0-10V, and 1-5V.
Product Usage Instructions
- Set the operator page and parameters on PAGE 0. Select the channel for temperature or humidity control setpoint. Set the temperature or humidity alarm setpoints with low and high limits.
- Adjust the ON-OFF control parameters on PAGE 11. Select the channel for temperature or humidity control function. Enable the control mode and set the setpoint low limit, setpoint high limit, and hysteresis.
- Configure the alarm parameters on PAGE 10. Select the channel for temperature or humidity alarm function. Set the alarm type and hysteresis for Alarm-1 and Alarm-2. Enable or disable the alarm latch and alarm inhibit.
- Configure the input type on PAGE 12. Select the channel for temperature or humidity input type. Set the signal low, signal high, range low, range high, and offset.
- Adjust the supervisory parameters on PAGE 13. Enable or disable the control set-point adjustment and alarm set-point adjustment on the operator page. Enable or disable the remote acknowledge switch and password for resetting min/max. Set the baud rate, parity, device slave ID, and serial write permission.
For more details on operation and application, please log on to www.ppiindia.net.
OPERATOR PAGE AND PARAMETERS
ON-OFF CONTROL PARAMETERS
ALARM PARAMETERS
INPUT CONFIGURATION PARAMETERS
SUPERVISORY PARAMETERS
RECORDER (RETRANSMISSION) PARAMETERS
TABLE- 1
FRONT PANEL LAYOUT
Keys Operation
PV Error Indications
ELECTRICAL CONNECTIONS
JUMPER SETTINGS
ENCLOSURE ASSEMBLY
MOUNTING DETAILS
SERIAL COMM. MODULE
CONTACT
Address: 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist.
Palghar – 401 210.
Sales: 8208199048 / 8208141446
Support: 07498799226 / 08767395333
E: sales@ppiindia.net,
support@ppiindia.net