COOPER IB505058ML APC/APCH Combo, and APXH Exit with Remote Capacity Instruction Manual

June 9, 2024
Cooper

IB505058ML APC/APCH Combo, and APXH Exit with Remote Capacity
Instruction Manual

IB505058ML
049-211
COOPER LIGHTING SOLUTIONS

IB505058ML APC/APCH Combo, and APXH Exit with Remote Capacity

Installation Instructions for the All Pro APC/APCH Combo, and APXH Exit with Remote Capacity

WARNING
Risk of Fire/Electric Shock
If not qualified, consult an electrician.

WARNING
Risk of Electric Shock
Disconnect power at fuse or circuit breaker before installing or servicing.

Important Safeguards

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING.

  1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS
  2. Do not use outdoors.
  3. Do not use in hazardous locations, or near gas or electric heaters.
  4. Do not let power supply cords touch hot surfaces.
  5. Use caution when servicing batteries. Battery acid can cause burns to skin and eyes. If acid is spilled on skin or in eyes, flush acid with fresh water and contact a physician immediately.
  6. Do not use this equipment for other than the intended use.
  7. Installation is to be performed only by qualified personnel.
  8. Install in accordance with National Electric Code and local regulatory agency requirements.
  9. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
  10. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
  11. SAVE THESE INSTRUCTIONS

DETERMINE CONFIGURATION / ASSEMBLE FIXTURE

  1. The APC and APCH Combos can be configured for wall, ceiling, or end mounting. The mounting method will determine where the heads can be mounted. The APXH exits have no heads on the fixture, but can be used to drive the APWR LED remote heads.
  2. Remove the exit sign stencil from the exit frame, to access the inside of the exit sign.
  3. If ceiling or end mounting, remove the appropriate hole plug, and snap in the canopy by sliding it in the keyhole opening. Place the canopy nose through the mounting  hole until the side of the frame touches the canopy. Lock the frame onto the canopy by sliding the frame in a direction parallel to the canopy length toward the narrow end of the mounting hole. Slide the frame until both snaps engage the canopy nose preventing any motion back out of the hole. (see Fig. 1)
  4.  Select the mounting locations for the heads. Remove the appropriate hole plug or slot covers. (see Fig. 2)
  5. Feed the wires for the heads through the mounting holes, and then snap the heads into place.
  6. Route the wires from the heads to the LED PCB. There are wire harnesses coming from the circuit board with keyed connectors that will mate with the connectors from the heads.

WALL MOUNT INSTALLATION

  1. De-energize the circuit at the junction box (J-box) where the exit sign is to be installed.
  2. Drill out the appropriate mounting pattern and the wire pass hole in the EXIT backplate to fit the J-box being used.
  3. Feed the orange, black, and white wires through the center hole.
  4. Connect the J-box wires to the EXIT power supply wires using the wire nuts provided. Connect the white wire to neutral. If using 120V, connect the black wire to the  hot lead. If using 277V, connect the orange wire to the hot lead. Cap the unused lead. Press the wires into the J-box.
  5. Secure the EXIT to the wall and/or junction box using installer supplied hardware.
  6. Attach battery leads to PCB.
  7. Snap the EXIT stencil onto the frame.
  8. Energize AC supply, LED display will come on. LED heads will illuminate briefly.

Installation Instructions for the All Pro APC/APCH Combo, and APXH Exit with Remote Capacity

COOPER IB505058ML APC APCH Combo and APXH Exit with Remote Capacity - Figure
1COOPER IB505058ML APC
APCH Combo and APXH Exit with Remote Capacity - Figure 2

CEILING OR END MOUNT INSTALLATION

  1. De-energize the circuit at the junction box (J-box) where the exit sign is to be installed.

  2. Place the provided screws in the canopy screw holes. Tabs inside the holes will prevent the screws from falling out during installation.

  3. Remove the appropriate mounting hole plug on the top (ceiling mount) or side (end mount) of the frame.

  4. Feed the orange, black, and white wires through the canopy nose.

  5.  Feed the wires from the J-box through the steel mounting plate, and then attach the mounting plate to the J-box with installer provided hardware.

  6. Connect the J-box wires to the EXIT power supply wires using the wire nuts provided. Connect the white wire to neutral. If using 120V, connect the black wire to the  hot lead.
    If using 277V, connect the orange wire to the hot lead. Cap the unused lead. Press the wires into the J-box.

  7. Secure the EXIT canopy to the steel mounting plate using the screws placed in the canopy in step 4.

  8. Attach battery leads to PCB.

  9. Snap the EXIT stencil onto the frame.

  10. Energize AC supply, LED display will come on. LED heads will illuminate briefly.

SELF POWERED OPERATION

Depress the test switch. The LED display will remain lit and the charge LED will extinguish when the switched to battery power. LED heads will illuminate as long as the  button is pushed. Release the test switch. The charge LED will illuminate and the LED display will operate from the AC supply. The LED heads will turn off.

MAINTENANCE

None required. Replace the batteries as needed according to ambient conditions. However, we recommend that the equipment be tested regularly in accordance with local codes.
NOTE: Servicing of any parts should be performed by qualified personnel. Only use replacement parts supplied by Cooper Lighting Solutions.
CAUTION: This equipment is furnished with a sophisticated low voltage battery dropout circuit to protect the battery from over discharge after its useful output has been  used. Allow 24 hours recharge time after installation or power failure for 90 minute testing.

TROUBLE SHOOTING GUIDE

If LED heads or charge indicator LED does not illuminate, check the following:

  1. Check AC supply – verify that unit has 24 hour AC supply.
  2. Unit is shorted or battery is not connected.
  3. Battery discharged. Permit unit to charge for 24 hours and then re-test.
  4. If following the above trouble shooting hints does not solve your problem, contact your local Cooper Lighting Solutions representative for assistance.

SCHEMATICS

COOPER IB505058ML APC APCH Combo and APXH Exit with Remote Capacity - Figure
3

Warranties and Limitation of Liability
Please refer to www.cooperlighting.com for our terms and conditions.

Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P:770-486-4800
www.cooperlighting.com
© 2020 Cooper Lighting Solutions
All Rights Reserved
Printed in USA
Publication No. IB505058ML
Cooper Lighting Solutions is a
registered trademark. All
trademarks are property
of their respective owners.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Cooper User Manuals

Related Manuals