Hamron 023629 Tyre Pump Instruction Manual

June 9, 2024
HAMRON

Hamron logo TYRE PUMP
OPERATING INSTRUCTIONS
Original instructions
Hamron 023629 Tyre Pump

023629 Tyre Pump

Jula AB reserves the right to make changes to the product. Jula AB claims copyright on this documentation. It is not allowed to modify or alter this documentation in any way and the manual shall be printed and used as it is in relation to the product. For the latest version of operating instructions, refer to the Jula website.
WWW.JULA.COM
© JULA AB 2022-09-19
JULA AB
BOX 363, 532 24 SKARA, SWEDEN

EU DECLARATION OF CONFORMITY
Item number 023692
Jula AB, Box 363, SE-532 24 SKARA, SWEDEN
This declaration of conformity is issued under the sole responsibility of the manufacturer.
LITHIUM PUMP
MAX 150PSI
Conforms to the following directives, regulations and standards:

Directive/Regulation Harmonized standard
MD 2006/42/EC EN ISO 12100: 2010, EN 60204-1:2018, EN 1012-1:2010
EMC 2014/30/EU EN IEC 55014-1:2021, EN IEC 55014-2:2021, EN IEC

61000-3-2:2019+A1, EN 61000-33:2013+A2
LVD 2014/35/EU| EN 62471:2008
RoHS 2011/65/EU + 2015/863| EN 50581:2012

This product was CE marked in year: -22
Skara 2022-05-30

Mattias Life
BUSINESS AREA MANAGER (Signatory for Jula and authorised to compile the technical documentation.
Hamron 023629 Tyre Pump - Figure 1Hamron 023629
Tyre Pump - Figure 2Hamron 023629
Tyre Pump - Figure 3

SAFETY INSTRUCTIONS

Read these instructions before use and save them for future reference.

  • Never leave the product unattended when switched on.
  • Keep flammable or explosive materials away from the product.
  • Do not subject the product to knocks and blows, or expose it to rain, moisture, sand or other impurities.
  • Store the product clean, cool and dry.
  • Recycle the product at the end of its useful life in accordance with local regulations.
  • Do not allow children to use the product without the supervision of an adult.
  • Risk of burn injury! The hose and its connection get hot when in use.
  • The product is intended for ambient temperatures from –10 to 45°C. Outside this range of temperatures the sub temperature protection or overheating protection can trip and switch off the product automatically.

SYMBOLS

| Read the instructions.
---|---
| Approved in accordance with the relevant directives.
| Recycle discarded product in accordance with local regulations.

TECHNICAL DATA

Voltage 7.4 V
Max working pressure 10.3 bar / 150 PSI
Free flow 20 l/min
Operating temperature –10 to 45°C
Battery capacity 14.8 Wh
Battery voltage and current 5 V, 2 A
Charging time 2 to 3 h
Hose length 15.5 cm
Size L 155 x W 64 x D 43
Weight 0.5 kg

DESCRIPTION

Portable mini compressor for inflation of tyres, bath toys etc.
Package contents:

  • Mini compressor (1)
  • Hose with connection for Schrader valve (1)
  • Adapter for Presto valve (1)
  • Needle nozzle for balls (1)
  • Nozzle for swim ring (1)
  • Charging cable (USB type C) (1)

Parts:

  1. Hose connection
  2. Charging connection (USB type C)
  3. Pressure gauge
  4. Unit
  5. Run mode
  6. Power switch
  7. Increase preset value
  8. Run mode switch
  9. Reduce preset value
  10. Power switch for LED
  11. Battery charging indicator
  12. LED
    FIG. 1

USE

CHARGING
A USB charger for 5 V, 2 A is recommended. The charger is connected to the product with the USB cable type C (included) when charging.
Flashing battery indicator: charging in progress.
Constant green light in battery indicator: battery fully charged.
The product cannot be used when charging is in progress.
Green light: 60–100%
Red light: 0–30%
FIG. 2

SWITCHING ON AND OFF

Press the power switch button for 3 seconds to switch on.
FIG. 3
Press the power switch button for 3 seconds to switch off.
FIG. 4
SWITCHING BETWEEN MODES
Tap the mode switch to step through the modes in the table.

Run mode Standard pressure Adjustment range
Car tyre 2.4 bar 0–4.5 bar
Motorcycle tyre 2.8 bar 0–3.8 bar
Bicycle tyre 2.6 bar 0–10 bar
Special 6.9 bar 0–10 bar
Ball/toy 0.6 bar 0–1 bar

PRESSURE UNIT SELECTION

Tap the pressure unit switch to step through the pressure units.
Conversion between different pressure units:
1 psi = 6.90 kPa, 1 bar = 100 kPa, 1 kg/cm2 = 98 kPa
PRESETTING AIR PRESSURE
Tap to increase (+) and reduce (–) to fine adjust the air pressure.
Press and hold increase (+) and reduce (–) to quickly change the air pressure.
NOTE:
The set run mode and air pressure are saved automatically in the product memory. The run mode only needs to be set if it is to be changed from previous use. If such a change is made the standard pressure for the new run mode is set automatically.

CONNECTION OF AIR HOSE

Connect the hose as shown in the figure.

  1. Schrader valve
  2. Presto valve
  3. Ball needle nozzle
    FIG. 5

PUMPING – START
Tap the power switch button to start pumping. The increase in the air pressure is shown in the pressure gauge display in real time during the pumping. The product makes a noise when in use and its hose and air connections get hot.
Avoid touching the air hose and hose connection – risk of burn injury.
PUMPING – STOP
Tap the power switch button to stop the pumping manually.
When changing run mode or the preset air pressure the set run mode and its standard air pressure flash three times, alternating with the measured air pressure.
FIG. 6
LED LIGHT
Press the light button (h) to switch on the LED light.
Press the light button (h) to switch off the LED light.
MEASURING AIR PRESSURE
Start the product and connect the air hose to the object in which the air pressure is to be measured. The air pressure is shown on the pressure gauge display.
RESET OF PRESSURE GAUGE
If the air pressure shown is not 0 when the product is started and is not connected to a tyre or ball, reset the pressure gauge by pressing the increase/reduce buttons at the same time for 3 seconds.
NOTE:
The product is set to zero before delivery. Deviations in the tolerance of the pressure gauge or use at different heights can cause the measured air pressure to deviate from zero even when the product is not connected to a tyre, ball or toy or any other inflatable object. Manual resetting can in such cases increase the precision of the product.

MAINTENANCE

  • Check the charge level of the battery, and charge when necessary. The product switches off automatically at low battery charge level. Charging should be carried out when the battery charge level is about 20%.
  • Make sure not to press the buttons on the product accidently, for example clenched in a bag or pocket. If a button is pressed for more than 6 seconds the product can start unintentionally.
  • Do not touch the hose or hose connection immediately after use – allow them to cool before disconnecting the hose.
    FIG. 7