Hamron 023629 Tyre Pump Instruction Manual
- June 9, 2024
- HAMRON
Table of Contents
TYRE PUMP
OPERATING INSTRUCTIONS
Original instructions
023629 Tyre Pump
Jula AB reserves the right to make changes to the product. Jula AB claims
copyright on this documentation. It is not allowed to modify or alter this
documentation in any way and the manual shall be printed and used as it is in
relation to the product. For the latest version of operating instructions,
refer to the Jula website.
WWW.JULA.COM
© JULA AB 2022-09-19
JULA AB
BOX 363, 532 24 SKARA, SWEDEN
EU DECLARATION OF CONFORMITY
Item number 023692
Jula AB, Box 363, SE-532 24 SKARA, SWEDEN
This declaration of conformity is issued under the sole responsibility of the
manufacturer.
LITHIUM PUMP
MAX 150PSI
Conforms to the following directives, regulations and standards:
Directive/Regulation | Harmonized standard |
---|---|
MD 2006/42/EC | EN ISO 12100: 2010, EN 60204-1:2018, EN 1012-1:2010 |
EMC 2014/30/EU | EN IEC 55014-1:2021, EN IEC 55014-2:2021, EN IEC |
61000-3-2:2019+A1, EN 61000-33:2013+A2
LVD 2014/35/EU| EN 62471:2008
RoHS 2011/65/EU + 2015/863| EN 50581:2012
This product was CE marked in year: -22
Skara 2022-05-30
Mattias Life
BUSINESS AREA MANAGER (Signatory for Jula and authorised to compile the
technical documentation.
SAFETY INSTRUCTIONS
Read these instructions before use and save them for future reference.
- Never leave the product unattended when switched on.
- Keep flammable or explosive materials away from the product.
- Do not subject the product to knocks and blows, or expose it to rain, moisture, sand or other impurities.
- Store the product clean, cool and dry.
- Recycle the product at the end of its useful life in accordance with local regulations.
- Do not allow children to use the product without the supervision of an adult.
- Risk of burn injury! The hose and its connection get hot when in use.
- The product is intended for ambient temperatures from –10 to 45°C. Outside this range of temperatures the sub temperature protection or overheating protection can trip and switch off the product automatically.
SYMBOLS
| Read the instructions.
---|---
| Approved in accordance with the relevant directives.
| Recycle discarded product in accordance with local regulations.
TECHNICAL DATA
Voltage | 7.4 V |
---|---|
Max working pressure | 10.3 bar / 150 PSI |
Free flow | 20 l/min |
Operating temperature | –10 to 45°C |
Battery capacity | 14.8 Wh |
Battery voltage and current | 5 V, 2 A |
Charging time | 2 to 3 h |
Hose length | 15.5 cm |
Size | L 155 x W 64 x D 43 |
Weight | 0.5 kg |
DESCRIPTION
Portable mini compressor for inflation of tyres, bath toys etc.
Package contents:
- Mini compressor (1)
- Hose with connection for Schrader valve (1)
- Adapter for Presto valve (1)
- Needle nozzle for balls (1)
- Nozzle for swim ring (1)
- Charging cable (USB type C) (1)
Parts:
- Hose connection
- Charging connection (USB type C)
- Pressure gauge
- Unit
- Run mode
- Power switch
- Increase preset value
- Run mode switch
- Reduce preset value
- Power switch for LED
- Battery charging indicator
- LED
FIG. 1
USE
CHARGING
A USB charger for 5 V, 2 A is recommended. The charger is connected to the
product with the USB cable type C (included) when charging.
Flashing battery indicator: charging in progress.
Constant green light in battery indicator: battery fully charged.
The product cannot be used when charging is in progress.
Green light: 60–100%
Red light: 0–30%
FIG. 2
SWITCHING ON AND OFF
Press the power switch button for 3 seconds to switch on.
FIG. 3
Press the power switch button for 3 seconds to switch off.
FIG. 4
SWITCHING BETWEEN MODES
Tap the mode switch to step through the modes in the table.
Run mode | Standard pressure | Adjustment range |
---|---|---|
Car tyre | 2.4 bar | 0–4.5 bar |
Motorcycle tyre | 2.8 bar | 0–3.8 bar |
Bicycle tyre | 2.6 bar | 0–10 bar |
Special | 6.9 bar | 0–10 bar |
Ball/toy | 0.6 bar | 0–1 bar |
PRESSURE UNIT SELECTION
Tap the pressure unit switch to step through the pressure units.
Conversion between different pressure units:
1 psi = 6.90 kPa, 1 bar = 100 kPa, 1 kg/cm2 = 98 kPa
PRESETTING AIR PRESSURE
Tap to increase (+) and reduce (–) to fine adjust the air pressure.
Press and hold increase (+) and reduce (–) to quickly change the air pressure.
NOTE:
The set run mode and air pressure are saved automatically in the product
memory. The run mode only needs to be set if it is to be changed from previous
use. If such a change is made the standard pressure for the new run mode is
set automatically.
CONNECTION OF AIR HOSE
Connect the hose as shown in the figure.
- Schrader valve
- Presto valve
- Ball needle nozzle
FIG. 5
PUMPING – START
Tap the power switch button to start pumping. The increase in the air pressure
is shown in the pressure gauge display in real time during the pumping. The
product makes a noise when in use and its hose and air connections get hot.
Avoid touching the air hose and hose connection – risk of burn injury.
PUMPING – STOP
Tap the power switch button to stop the pumping manually.
When changing run mode or the preset air pressure the set run mode and its
standard air pressure flash three times, alternating with the measured air
pressure.
FIG. 6
LED LIGHT
Press the light button (h) to switch on the LED light.
Press the light button (h) to switch off the LED light.
MEASURING AIR PRESSURE
Start the product and connect the air hose to the object in which the air
pressure is to be measured. The air pressure is shown on the pressure gauge
display.
RESET OF PRESSURE GAUGE
If the air pressure shown is not 0 when the product is started and is not
connected to a tyre or ball, reset the pressure gauge by pressing the
increase/reduce buttons at the same time for 3 seconds.
NOTE:
The product is set to zero before delivery. Deviations in the tolerance of the
pressure gauge or use at different heights can cause the measured air pressure
to deviate from zero even when the product is not connected to a tyre, ball or
toy or any other inflatable object. Manual resetting can in such cases
increase the precision of the product.
MAINTENANCE
- Check the charge level of the battery, and charge when necessary. The product switches off automatically at low battery charge level. Charging should be carried out when the battery charge level is about 20%.
- Make sure not to press the buttons on the product accidently, for example clenched in a bag or pocket. If a button is pressed for more than 6 seconds the product can start unintentionally.
- Do not touch the hose or hose connection immediately after use – allow them to cool before disconnecting the hose.
FIG. 7
Documents / Resources
|
Hamron 023629 Tyre
Pump
[pdf] Instruction Manual
023629 Tyre Pump, 023629, Tyre Pump, Pump
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>