LEXON LL153 Soft Power Mag Bank User Manual

June 3, 2024
LEXON

LEXON Logo LL153 Soft Power Mag Bank User ManualLEXON LL153 Soft Power
Mag Bank - Fig 2

LL153 Soft Power Mag Bank

Tank you for purchasing Softpower MagBank. lease read this user manual carefully before operating your device and save it for future reference.
IN THE BOX
lx Softpower MagBank lx USB Type-C cable lx User manual

PRODUCT OVERVIEW

  1. Magsafe ring
  2. Wireless charging transmitter
  3. magsare alignment magnet
  4. wireless charging LED indicator
  5. USB Type-C In/Out port
  6. battery level LEDs indicator
  7. over On/011

PE RATIONS & USE

  • harging the powerbank
    1. Connect the supplied USB Type-C Cable into thc powcrbank port 2. lug the other end to a USB charger
Status ED 1 ED 2 – 5
hanging ff The highest-level LED, flashing white; the LEDs under levels,olid

white
Full charged| IT| Old while

ED information

LED 1: Wireless Charging LED (Blue)
LED 2: 5% Battery Level LED (White)
LED 3: 50% Battery Level LED (White)
LED 4: 75% Battery Level LED (White)
LED 5: 00% Battery Level LED (White)

  • harging your iPhones 12/13 and greater
    1. Press the power button to activate the wireless charging function.
    2. Place the power bank on the hack of your iPhone.
    Note: Your power bank will magnetically attach Lo your Phone. o remove the power bank, gently pull it off the back of your iPhone.

  • Charging other Qi-enabled phones oftpower Magbank is compatible with all Qi-enabled phones.
    1. Press the power button to activate the wireless charging function. 2. Align the center of your mobile device with the power bank at the wireless charging area.
    If the charging icon/indicator doesn’t show on your mobile device, try 1.0 adjust its position tatus| ED 1| ED 2 — 5
    ---|---|---
    Wireless Charging activated| lashing blue twice then Off| hawing the current battery level
    ireless charging| of id Blue| howing the currenl_ battery level
    ully charged| ff| ff
    oreign object detected| lashing blue| howing the current battery level

  • harging other devices with a charging cable 1. ‘redly plug the cable into the Type-C port of the powerbank. 2. Connect the other end to the device.
    o need to press the power on/off button to start charging your device.

Status ED 1 ED 2 — 5
harging II hawing the current battery level
Fully charged ff ff

SAFETY PRECAUTIONS

Read all the instructions before using the device:

  • Keep your device dry. Never place your device in water to avoid causing internal short-circuit, over-heating, lire, deformation, or even explosion of the battery.
  • Do not store your device in very hot or cold areas. It is recommended to use your device at room temperatures.
  • Do not expose your device to direct sunlight for an extended period of time.
  • Keep your device out of reach of small children to prevent danger.
  • Do not put metal objects or magnets between the mobile device and the wireless charging surface.
  • Please stop using your device immediately if it bulges, leaks, or smells, and contact the Manufacturer for service.
  • Do not attempt to service, repair or disassemble the device by yourself

TECHNICAL SPECIFICATIONS

Dimensions: 3.54 x .37x 0.39″ / 9 x 6.2 x 1.2 cm
Material Synthetic leather
Weight 0.22 lb / 100 g
Charging system: via USB Type-C cable (included),
power supply (not included)
Input: Type-C 5V-2.4A
Output: Type-C 5V-2.4A
Wireless power: 5W| Battery type: Li-polymer
Battery capacity: 3000 mAh
Battery voltage: 3.7V
Coil: 1 coil
Charging time: 2h
Operating temperature: O – 30t
International warranty: 1 year
---|---

Wireless charging compatibility: Compatible with all Qi-enabled phones Softpower Magbank is charging efficiency depends on whether the phone supports it. Feel free to check our compatibility 1st on our website. lexon- design.com
Magsafe compatibility: iPhone 13 / iPhone 13 Pro / iPhone 13 Pro Max / iPhone 13 Mini, iPhone 12 / iPhone 12 Pro / iPhone 12 Pro Max / iPhone 12 Mini and greater Not compatible with non MagSafe protective cases

EUROPEAN UNION CE DIRECTIVE

LEXON hereby declares that the device complies with the essential requirements and other relevant provisions of Directives 2014/53/EU & 2011/65/EU. The original EU declaration of conformity may be found at: https://www.lexon- design.com/assets/certifications-ce-softpowermagbank.pdf

Radiated H-Field -2.92 dBuA/m (@10m)
TX/RX Frequency Range 110-148kHz(Only for EU&U K)

UK conformity assessment
The object described above is in conformity with the essential requirements and other relevant provisions of the UK Radio Equipment Regulations 2017 (SI 2017/1206). The original UK declaration of conformity may be found at: https://www.lexon-design.com/assets/certifications-ce- softpowermagbank.pdf
DISPOSAL AND RECYCLING INFORMATION
After the implementation of the European Directive 2012/19/EU in the national legal system, the following applies : electrical and electronic devices may not be dis-posed of with domestic waste. Consumers are obiged by law to return electrical and electronic device at the end of their service lives to the public collecting points set up for this purpose or point of sale. Details to this are defined by the national law of the respective country. This symbol on the product, the instruction manual or the package indicates that a product is subject to these regulations. By recycling, reusing the materials or other forms of utilizing old devices, you are making an important contribution to protecting our environment.

USA – FCC STATEMENT FC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.Notice: Any changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates. uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna,
  • Increase the separation between the equipment and receiver.
  • Conned the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help. FCC RF exposure statement: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

CANADIAN COMPLIANCE STATEMENT
This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-003.

RF exposure statement: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

125, Avenue des Champs-Elysées – 75008 Paris – FRANCE
All ore-ds or brother rid-10:i are may  be Redermerks or their respective owners.
pictures and specircaliens are -el. 00W-dr:ma Accessible in China. lexon- design.com I @lexondesign

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals