LEXON LH59 Wireless Charging Station with Built-In UV Sanitizer User Manual

June 3, 2024
LEXON

LEXON LOGO LH59
OBLIVION
User Manual

LH59 Wireless Charging Station with Built-In UV Sanitizer

LEXON LH59 Wireless Charging Station with Built In UV Sanitizer - FIGURE
1

  1. Wireless Charging surface
  2. Wireless LED indicator
  3. UV Sanitizer LED
  4. UV On/Off button
  5. USB Type-C port

PRECAUTIONS FOR USE
During operation, the LED emits high-intensity ultraviolet (UV) light, which is harmful to the skin and eyes.
UV light is hazardous to the skin and may cause cancer. Avoid exposure to UV light when LED is operational.
Precautions must be taken to avoid looking directly at the UV light without the use of UV light protective glasses. Do not look directly at the front of the LED or at the LED’s lens when LED is operational.

CHARGING

Connect the USB-C charging cable to a USB Certified plug adaptor.
Plug the USB-C connector into the back of your device (5).
When Oblio is successfully powered to an electrical source, the white LED light will light up for a few seconds.
IMPORTANT: To get your charging station properly operating, you need to use a Quick Charge 3.0 certified power adaptor or a DC 9V 2A USB Power adaptor.
Using a different charger or adaptor with a lower specification than mentioned above, may significantly affect the wireless charging performance and cause irreversible damage to your device.
It is strongly recommended to plug your power adapter directly into the wall socket and avoid using an extender or power strip that may cause interferences and affect good working operations.

WIRELESS CHARGING

Charging Mobile Device

  1. Place your wireless charging-enabled smartphone inside the charging station, face up. Kindly note that Oblio only works with all Qi-compatible devices. Please contact your smartphone manufacturer or check your mobile phone user manual to ensure that your device is Qi-certified. The charging function activates automatically.
    Check the charging icon displayed on the mobile phone screen for charging status.

  2. When the mobile device is fully charged it will stop automatically to protect your device.

Average charging time for iPhone X: 3h30
Average charging time
for iPhone XS Max: 4h
Average charging time for Samsung 510: 3h30
Average charging time
for Samsung S9: 3h
Average charging time for Samsung N9: 3h
Ambient temperature: 22/25°C
Kindly note that room temperature may have an impact on the smartphone’s charging time.
Note: Be sure to properly place the back of your smartphone resting against the wireless charging surface in order to charge it. Wireless charging may not work if you have attached a thick or metallic protective case to your mobile phone. Oblio supports up to 3 mm in thickness for reference.
Light status indicator

Operation mode LED (2)
Power supply LED light will light up for 3 seconds
Start charging LED light flashing slowly
Fully charged Steady white light
Foreign object detected Flashing for 10 sec then shut down

If the indicator light does not work as described above, unplug the charger from the wireless charger and reconnect it.

UV SANITIZER
UV sanitizer function is ON by default. Oblio eliminates up to 99% of the bacteria present on the treated surface.
To disable it permanently, press the physical button located underneath the unit.
UV sanitizer ON

  1. Place your phone in the charging station
  2. A purple light will light up to indicate that your smartphone is in the sterilization phase.
  3. UV sanitizer function activates automatically and will take about 20 minutes to complete its sanitizing cycle.
  4. The UV lamp turns off automatically when the sterilization phase is completed.

Note: If the phone is extracted during the sanitization phase, UV sanitizer will stop automatically. The cycle will start again from the beginning.

SAFETY PRECAUTIONS:

Read all the instructions before using the device:

  1. Wireless charging may not work if you have attached a thick or metallic protective case to your mobile phone.
  2. Wireless charging is slower than wire charging.
  3. Use indoors and in a dry location only.
  4. Avoid contact with liquids: keep away from water and high moisture conditions.
  5. No hitting the product severely, inserting any conductive objects into the product, or charging port.
  6. Do not put metal objects or magnets between the mobile device and the wireless charger surface.
  7. Do not store your device in very hot or very cold areas. It is recommended to use your device at room temperature.
  8. Do not repair the device by yourself; seek professional service.
  9. Avoid getting shocked, and do not touch the product with wet hands.

PRODUCT SPECIFICATIONS:

Case material: ABS & Polycarbonate
Net Weight: 430 g
Dimension: 7 x 17.5 x 13.6 cm
Phone slot dimension: max. 6.5 inch
UV sanitizer:

  1. UV power output: 4mW
  2. UV sterilization time: 20 mins
  3. UV sterilization efficiency: > 99

Wireless charge:

  1. Use: Mobile Phone (Qi-certified phones only)
  2. Wireless charging output: Up to 10W (depending on mobile phone & and input power)
  3. Transmission distance: 3-6mm
  4. Coil: Single Coil
  5. Transmit power: 10W/7.5W/5W
  6. Input: DC 9V/2A or QC 3.0 adaptor
  7. AC input port: Type C
  8. Operating temperature: -10°C/50°C

PRECAUTIONS FOR USE
During operation, the LED emits high-intensity ultraviolet (UV) light, which is harmful to the skin and eyes. UV light is hazardous to the skin and may cause cancer. Avoid exposure to UV light when LED is operational. Precautions must be taken to avoid looking directly at the UV light without the use of UV light protective glasses. Do not look directly at the front of the LED or at the LED’s lens when LED is operational.
EUROPEAN UNION
CE DIRECTIVE
LEXON hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/53/EU and 2012/19/EU.
The original EU declaration of conformity may be found at: https://www .lexon-design.com/assets/certifications-ce-oblio.pdf
DISPOSAL AND RECYCLING INFORMATION
After the implementation of the European Directive 2012/19/EU in the national legal system, the following applies: electrical and electronic devices may not be disposed of with domestic waste. Consumers are obliged by law to return the electrical and electronic devices at the end of their service lives to the public collecting points set up for this purpose or point of sale. Details of this are defined by the national law of the respective country. This symbol on the product, the instruction manual, or the package indicates that a product is subject to these regulations. By recycling, reusing materials, or other forms of utilizing old devices, you are making an important contribution to protecting our environment.
USA – FCC STATEMENT
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

CAUTIONS
Any changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help.

RF exposure statements
This equipment complies with the FCC radiation exposure requirements set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance.
FCC ID: 2ARD3-LH059
CANADA – ISED STATEMENT
This device complies with Industry Canada license-exempt RSS. Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-0003.

RF exposure statements
This device complies with the ISED RSS-102 RF exposure requirement set forth for an uncontrolled environment and is safe for intended operation as described in this manual.
IC 24406-LH059

LEXON LH59 Wireless Charging Station with Built In UV Sanitizer -
ICON 125, Avenue des Champs-Elysées – 75008 Paris – FRANCE
All brands or product names are or may be trademarks of their respective owners.
Pictures and specifications are not contractual. Assembled in China.
Lexon-design.com

Documents / Resources

| LEXON LH59 Wireless Charging Station with Built-In UV Sanitizer [pdf] User Manual
LH59 Wireless Charging Station with Built-In UV Sanitizer, LH59, Wireless Charging Station with Built-In UV Sanitizer, Charging Station with Built-In UV Sanitizer, Built-In UV Sanitizer, UV Sanitizer, Sanitizer
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>