AURORALIGHT UDW427144 Ariel is an Amphibious IP68, Directional LED Luminaire Installation Guide
- September 22, 2024
- auroralight
Table of Contents
UDW427144 Ariel is an Amphibious IP68, Directional LED Luminaire
“`html
Product Information
Specifications:
-
Model: UDW427144
-
Required Tools: 3/32 Allen Key (Included), Wire
Cutter/Stripper -
Wire Type: 20AWG
-
Location: Suitable for wet or dry installation
-
Manufacturer Contact: P. 760.931.2910, E.
techsupport@auroralight.com, O. 2742 Loker Ave. W Carlsbad CA
92010, W. www.auroralight.com
Product Usage Instructions
-
Pre-Installation:
-
Disconnect the transformer from the electrical supply and
ensure power is off. -
Always have a licensed electrician install the fixture.
-
-
Fixture Mounting:
-
Unscrew the wing nut to remove the fixture from the mount
bracket. -
Secure the mount bracket in the desired location using provided
screws or anchors. -
Reattach the fixture to the mount bracket and tighten the wing
nut by hand. -
Adjust the fixture direction as needed.
-
Wire Connection:
-
Connect the 20AWG wires to the main supply cable using UL
listed connectors suitable for underground and wet locations. -
Use appropriate UL listed underground feeder (UF) cable for
connections.
-
Important Notes:
This fixture is factory-sealed; do not unscrew pre-assembled
caps or cord seal to avoid leakage and failure.
Warnings:
Luminaire installation must comply with local codes and NEC to
prevent injury or damage.
Risk of electric shock; follow NEC Code 680.22(B (6) if
installing near pools, spas, or fountains.
Frequently Asked Questions (FAQ)
Q: Can I install the fixture without a licensed
electrician?
A: It is recommended to always have a licensed electrician
install the fixture to ensure safety and proper installation.
Q: What wire size should I use for the connections?
A: Use 20AWG wires to connect to the main supply cable and
ensure UL listed connectors are used for underground and wet
locations.
“`
ARIEL INSTALL GUIDE
UDW427144
REQUIRED TOOLS:
3/32″ Allen Key (Included) Wire Cutter / Stripper
INSTRUCTIONS:
1. To prevent electrical shock, disconnect transformer from electrical supply
and make sure power supply is completely off before installation. Fixtures
should always be installed by a licensed electrician.
2. Remove the fixture from the mount bracket by unscrewing the wing nut and
sliding out (see figure). Set aside and take caution to not lose any of the
hardware or O-rings from that area.
3. Secure the mount bracket in the desired wet or dry location using the
provided mount screws and/or anchors if mounting in stone or tile (a 1/8″
pilot hole is recommended when mounting in wood).
4. Run the 2x 20AWG cable to a dry location nearby. Separate the 2 internal
conductors by stripping the large outer insulation first, then strip about ¼”
off the end of each individual conductor (see figure).
5. Reattach the fixture to the mount bracket and tighten down the wing nut by
hand (see figure).
6. Rotate the fixture on the post to aim in it in the desired direction.
7. Connect the 20AWG wires to the main supply cable using UL listed
connectors suitable for underground and wet location as well as the
appropriate UL listed underground feeder (UF) cable (see figure).
MOUNT SCREWS
FIXTURE
POST
MAKE WIRE CONNECTION IN UNDERGROUND OR DRY LOCATION
UL LISTED WIRE CONNECTOR
WING NUT
MOUNTING SURFACE MOUNT BRACKET
MAIN SUPPLY CABLE 2X 20AWG CABLE
P. 760.931.2910 E. techsupport@auroralight.com O. 2742 Loker Ave. W Carlsbad CA 92010 W. www.auroralight.com
Important! This fixture is assembled and sealed at the factory, do not unscrew any of the pre-assembled caps or the cord seal. Doing so could result in leakage and failure.
WARNING: Luminaire must be
installed in accordance with local
codes and the National Electrical
Code (NEC). Failure to do so may result in serious injury and or damage to the
luminaire.
WARNING: Risk of electric
shock. Install per NEC Code 680.22(B (6), if listed low voltage luminaires are
to be
located near a pool, spa or fountain.