coVita Micro+ pro Smokerlyzer User Manual

June 10, 2024
coVita

coVita Micro+ pro-Smokerlyzer

coVita-Micro+pro-Smokerlyzer-product

Product Information

The coVita Micro+TMpro CO Monitor is a device designed to help people stop smoking by monitoring their carbon monoxide levels. The device comes with a D-PieceTM one-way valve that filters out viral particles and bacterial spores, a SteriBreathTM mouthpiece for single use, a USB cable, and a carrying bag for monitor and accessory storage. The device has an LCD display and a power button. The monitor should be calibrated every 6 months to correct for sensor drift using 20 ppm coVita calibration gas. The D-pieceTM valve should be replaced every 28 days.

Infection Control Technologies
The coVita Micro+TMpro CO Monitor comes with industry-leading infection control technologies to prevent cross-infection. The D-pieceTM valve contains a one-way valve and an integrated infection control filter that can filter out viral particles and bacterial spores. The D-pieceTM filters have been independently tested and were found to be effective against bacterial and viral pathogens, including COVID-19/SARS-COV-2. The SteriBreathTM mouthpieces are made entirely from paper and are 100% recyclable and biodegradable. The mouthpieces are individually wrapped for convenience, ease of handling, and greater infection control. coVita offers alcohol-free cleansing wipes that are specifically engineered for use on their monitors and accessories. These wipes have been tested against H5N1 Avian Flu and H1N1 Swine Flu and found effective against 99.999% of germs, spores, bacteria, and fungi.

Product Usage Instructions

  1. Replace the D-pieceTM valve every 28 days.
  2. Calibrate the device every 6 months to correct for sensor drift using 20 ppm coVita calibration gas.
  3. Do not oversaturate the screen with liquid when wiping down your monitor. This can leak into the PCB board and cause damage.
  4. Never store the monitor around cleansing products containing harsh chemicals, other cleaning agents, or solvents.
  5. Never block the air/vent hole on the back of the monitor with labels.
  6. To perform a breath test, insert the SteriBreathTM mouthpiece into your mouth and exhale as hard as you can until your lungs are empty. The device will display your carbon monoxide levels.

Welcome from the coVita Family

Dear Valued coVita Client,
Thank you for being part of the coVita family where we are celebrating 30+ years of saving and improving lives with our Smokerlyzer® monitors.

We wanted to remind you of the following:

  • coVita includes U.S.A.-based complimentary lifetime telephone support and online training courses
  • Access to coVita’s staff of Certified Tobacco Treatment Specialists (CTTS)
  • coVita includes an industry-leading 5-year warranty on the Micro+™ pro, baby, basic Smokerlyzer® family of monitors

Please review coVita’s new website & Education Destination at www.covita.net/support/.

Here you will find the following complimentary information:

  • Online Training Course
    • Quiz for Certification and Certificate of Completion
  • Reference Guides
    • Quick Start, Calibration, Use & Infection Control Guides
    • CPT Codes for Reimbursement
    • Logs for Groups & Individuals
    • Interpretation Materials
    • Hand Outs & Explanations of the CO Readings
    • Instructional Videos

The coVita family values and appreciates our relationship. Together we can make a difference in peoples’ lives everyday.

Sincerely, the coVita Family.

Product Contents

coVita-Micro+pro-Smokerlyzer-fig-1

  1. Micro+™pro CO Monitor
  2. D-Piece™ One-Way Valve to filter out viral particles & bacterial spores (replaced every 28 days)
  3. SteriBreath™ Mouthpiece (single use)
  4. USB Cable
  5. (3) AA Alkaline Batteries – USE ONLY ALKALINE
  6. Monitor Microfiber Sleeve – can be used to protect and clean your monitor screen
  7. Carrying bag for monitor & accessory storage
  8. Quick Start Guide
  9. Smokerlyzer® CO conversion charts: MaternityCO Chart – COppm to %FCOHb & %COHb
  10. Smokerlyzer® Poster
  11. Infection Control Guide

Note: Full Manual & COdata+ patient database software can be downloaded at www.covita.net.

Monitor Layout

  1. LCD Display
  2. Power Button
  3. SteriTouch™- patented additive integrated into the monitor housing, engineered to kill 99.99% bacteria on contact
  4. D-Piece™ Valve Opening
  5. Exhaust Port – DO NOT COVER
  6. USB Connector
  7. Vent Hole – DO NOT COVER WITH LABELS ETC.
  8. Battery Compartment
  9. Battery compartment clip
  10. Reset Button**
  11. Programming Switch**coVita-Micro+pro-Smokerlyzer-fig-2

DO NOT USE UNLESS INSTRUCTED BY COVITA

Tips & Maintenance

  1. Change your D-piece™ valve every 28 days.
  2. Calibrate every 6 months to correct for sensor drift using 20 ppm coVita calibration gas.
  3. Don’t oversaturate the screen with liquid when wiping down your monitor. This can leak into the PCB board and can cause damage.
  4. Never store your monitor around cleansing products containing harsh chemicals, other cleaning agents or solvents.
  5. Never block the air/vent hole on the back of the monitor with labels.

Industry Leading Infection Control Technologies

The surface of your monitor has an added material known as SteriTouch®, an antimicrobial product, that offers protection against a range of bacteria including E.coli, MRSA, Salmonella, and Legionella, as well as black mold growth, biofilm, and fungi1.

A statement from SteriTouch® manufacturer states “Coronavirus COVID-19 is an enveloped virus, so called because of its fatty outer membrane or ‘envelope’. Several of the active substances we use have been successfully tested against other enveloped viruses, such as Influenza, Avian flu, and SARS. It would be reasonable to imply that those same active substances would be effective against COVID-19, but at this stage testing against COVID-19 is not available .”coVita-Micro+pro-Smokerlyzer-fig-3

D-piece™ Valves
The D-piece™ contains a one-way valve and an integrated infection control filter with the ability to filter out viral particles and bacterial spores. The D-piece™ filters have been independently tested for the prevention of cross-infection. We are happy to announce that based on this data Bedfont concluded that bacterial and viral pathogens including (COVID-19 / SARS-COV-2) will effectively be removed by the D-piece™ filter at an efficiency rate of

99% (bacteria) and >97% (viruses).

  • Replace Monthly

SteriBreath™ Eco Mouthpieces

  • The SteriBreath™ mouthpieces are for single-use ONLY.
  • SteriBreath™ Eco mouthpieces are entirely made from paper and are 100% recyclable and 100% biodegradable.
  • The mouthpieces are individually wrapped for convenience, ease of handling, and greater infection control.

Wipes & Hand Sanitizers 

  • NEVER STORE your monitor around cleansing products containing harsh chemicals or other cleaning agents or solvents.

coVita offers alcohol-free cleansing wipes which are specifically engineered for use on our monitors and accessories. Effective against 99.999% of Germs, Spores, Bacteria, and Fungi. Tested against H5N1 Avian Flu and H1N1 Swine Flu. Additionally, been tested by the supplier and found effective against (COVID-19 / SARS-COV-2), as the product shows efficacy against feline coronavirus, a surrogate coronavirus (for COVID-19 / SARS-COV-2).

Additionally, coVita offers a hand sanitizer that was designed to safely and gently cleanse your hands. Because it’s engineered to be alcohol-free, its gentle on your hands and it won’t interfere with your monitor’s sensor or accessories. Kills 99.99% of germs, bacteria, & fungi without drying your skin.

How to Perform a Breath Test

  1. Turn on the monitor by pressing & releasing the button on top of the monitor.

  2. Insert a D-piece™ & SteriBreath™ mouth-piece into the monitor.
    Note: Round opening of D-piece™ faces you.

  3. Press the Female or Male Breath Test icon when ready to begin a test.

  4. Instruct the patient to take a deep breath and hold.

  5. The patient should hold their breath during the 15-second countdown period.

  6. At the end of the countdown when you hear the third beep instruct the patient to place mouth on the mouthpiece and exhale all of the air out of their lungs.

  7. The monitor has finished interpreting the sample when the three icons appear at the bottom of the screen. The readings will be displayed in PPM, %COHb.
    Note: If testing a pregnant woman press the fetus icon to see the fetal conversation. To return to the previous screen press the fetus. Press the home icon to return to the main home screen.

Key Features & Tips

LOG:
The monitor auto-logs the last 150 readings with a time and date stamp. The log can be accessed by pressing the gear icon on the home screen and then pressing the log icon. Press the arrow to scroll through the pages of readings. Press the home icon to return home.

On/Off:
To turn off your monitor press and hold the power button for 3 seconds. The monitor will also power off after 2 minutes of inactivity to save power.

Contact Information

www.covita.net | 800.707.5751

© Copyright 2023 coVita LLC All Rights Reserved v042123.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals