AURORALIGHT UDW427244 Ariel Directional LED Luminaire Installation Guide

September 14, 2024
auroralight

AURORALIGHT UDW427244 Ariel Directional LED Luminaire

Product Specifications

  • Model : UDW427244
  • Power Supply : 20AWG wires
  • Installation Location: Underground or Wet Location
  • Required Tools: 3/32 Allen Key, Wire Cutter/Stripper

Product Usage Instructions

  1. Safety Precautions
    Before installation, ensure the power supply is completely off and the transformer is disconnected to prevent electrical shock. Always have the fixtures installed by a licensed electrician to ensure safety.

  2. Wire Connection
    Connect the 20AWG wires to the main supply cable using UL-listed connectors suitable for underground and wet locations. Make sure to use the appropriate UL listed underground feeder (UF) cable for installation.

  3. Fixture Adjustment
    For light aiming, loosen the wing nut and rotate the fixture in the desired direction. Once adjusted, tighten the wing nut securely to hold the position.

  4. Mounting Options
    You can choose to mount the fixture using a ground stake or surface mount. Ensure proper mounting for stability.

  5. Important Note
    Do not unscrew any pre-assembled caps or cord seal on the fixture as it may cause leakage and failure. Follow all instructions carefully to maintain product integrity.

INSTRUCTIONS

  1. To prevent electrical shock, disconnect transformer from electrical supply and make sure power supply is completely off before installation. Fixtures should always be installed by a licensed electrician.
  2. Using the ½” thread post, thread the mount bracket and fixture down on to your ground stake or surface mount (see figure).
  3. Run the 2x 20AWG cable to a dry location nearby. Separate the 2 internal conductors by stripping the large  outer insulation first, then strip about ¼” off the end ofeach individual conductor (see figure).
  4. Connect the 20AWG wires to the main supply cable using UL listed connectors suitable for underground and wet location as well as the appropriate UL listed underground feeder (UF) cable (see figure).
  5. For light aiming, loosen the wing nut and rotate the fixture in the desired direction. Tighten the wing nut down when finished (see figure)

Important! This fixture is assembled and sealed at the factory, do not unscrew any of the pre-assembled caps or the cord seal. Doing so could result in leakage and failure.

REQUIRED TOOLS:
3/32” Allen Key (Included) Wire Cutter / Stripper

WARNING :

  • Luminaire must be installed in accordance with local codes and the National Electrical Code (NEC). Failure to do so may result in serious injury and or damage to the luminaire.
  • Risk of electric shock. Install per NEC Code 680.22(B (6), if listed low voltage luminaires are to be located near a pool, spa or fountain.

FAQ

Q: What should I do if the fixture is not aiming correctly?
A: Loosen the wing nut, adjust the direction of the fixture, and tighten the wing nut securely to ensure proper aiming.

Q: Can I install the fixture near a pool or spa?
A: If installing near a pool, spa, or fountain, ensure compliance with NEC Code 680.22(B (6) for low voltage luminaires to prevent the risk of electric shock.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>