Lighting Direct 512-84-L Vantage 24 Wide Adjustable CCT LED Vanity Strip Installation Guide

September 20, 2024
Lighting Direct

512-84-L Vantage 24 Wide Adjustable CCT LED Vanity Strip

“`html

Specifications:

  • Model Numbers: 511/512/513/514-84/66A/787-L

  • Dimming: Dimmable with ELV and/or LED compatible wall dimmer
    switches

  • Color Temperature: 2700K / 3000K / 3500K / 4000K / 5000K

Product Usage Instructions:

Preparation:

  1. Shut off power at the fuse box or circuit breaker box and
    remove the old fixture including the mounting hardware.

  2. Carefully unpack your new fixture and lay out all the parts in
    a clean area. Take care not to misplace any small parts necessary
    for installation.

Installation & Assembly:

Follow these steps for installation and assembly:

  1. Attach mounting plate (A) to junction box, ensuring it is
    flushed and leveled before tightening with Junction box screws
    (B).

  2. Clamp canopy (C) to mounting plate (A) following Fig.1, then
    lock it with screws (D).

  3. Make electrical wiring connections between fixture and power
    supply (see Electrical Wiring below).

  4. Place fixture in the correct position onto canopy (C), ensuring
    the sides are aligned, then lock the fixture screws (E).

Electrical Wiring:

Follow these steps for electrical wiring:

  1. Strip 3/8” of bare power supply wires from junction box.

  2. Connect neutral wire (white) from junction box to neutral wire
    (white) from fixture.

  3. Connect hot wire (black) from junction box to live wires
    (black) from fixture.

  4. Connect green ground wire from fixture to green or bare copper
    ground wire from junction box, using wire nuts (D).

  5. Once connections are complete, carefully push wires back inside
    the junction box.

Note: Select the desired Color Temperature
(CCT) by using the switch on the canopy of the fixture.

Important: Fixture should be installed by a
qualified electrician to ensure proper wiring and installation.

FAQ:

Q: Can I use cleaners with chemicals on the fixture?

A: No, DO NOT use any cleaners with chemicals,
solvents, or harsh abrasives on the fixture. Use a clean, soft
cloth for maintenance.

Q: How do I change the Color Temperature of the fixture?

A: You can select the desired Color Temperature
(CCT) by using the switch on the canopy of the fixture. The
available options are 2700K, 3000K, 3500K, 4000K, and 5000K.

“`

INSTALLATION INSTRUCTIONS
Item#511/512/513/514-84/66A/787-L READ AND SAVE THESE INSTRUCTIONS
WA R N I N G ! S H U T P O W E R O F F AT F U S E O R C I R C U I T B R E A K ER .
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU READ AND SAVE THESE INSTRUCTIONS DISJONCTEUR

PREPARATION

1. Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.

2. Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
INSTALLATION & ASSEMBLY (Fig.1)
3. An octagonal junction box must be installed at each desired location, before installing fixture. The box must have a depth of at least ½”. 4. Pull power supply wires from junction box through the center opening of mounting plate.

Care and maintenance
Use a clean, soft cloth to wipe the surface of fixture. DO NOT use any cleaners with chemicals, solvents, or harsh abrasives. Dimming: Dimmable with ELV and/or LED compatible wall dimmer switches.
Fig.1

5. Attach mounting plate (A) to junction box, make sure mounting plate is flushed and leveled before tightening with Junction box screws (B).

6. Follow Fig.1 in the correct direction, clamp canopy (C) to mounting plate (A), and then lock it with screws (D).

7. Make electrical wiring connections between fixture and power supply (see ELECTRICAL WIRING below).

8. After the wiring is complete, place fixture in the correct position onto canopy (C), making sure the 2 sides are stuck.

9. Lock the fixture screws (E).
ELECTRICAL WIRING (Fig. 2)
Strip 3/8” of bare power supply wires from junction box. Follow the wiring connection guide to connect wires from fixture to power supply wires from junction box, using wire nuts.

Mounting Plate *1

A-021-A

Canopy *1

Junction Box Screws *2

Screws *2

Fixture Screws *2

Wire Nuts *3

Connect neutral wire (white) from junction box to neutral wire (white) from fixture.

Connect hot wire (black) from junction box to live wires (black) from fixture.

Connect green ground wire from fixture to green or bare copper ground wire from junction box, using a wire nuts (D).

Once the connections are done, carefully push wires back inside junction box.

There are five CCTs (2700K / 3000K / 3500K / 4000K / 5000K) with this fixture. Select the desired CCT by using switch on canopy of fixture.
Your installation is now complete. Return power and test the fixture.
IMPORTANT: FIXTURE SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN TO ENSURE PROPER WIRING AND INSTALLATION.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lighting Direct User Manuals

Related Manuals