M77R2 is equipped with a fixed 2.8mm @ F1.6 lens and true WDR, and supports h.265 codec compression.
Note: h.265 codec is supported by SRX-Pro v7 and above only. For backwards compatibility, change the codec to h.264 in the camera’s web settings > Config

Image > Video/Audio > Video Compression.

SAFETY

When installing your M77 camera be sure to avoid:

  • excessive heat, such as direct sunlight or heating appliances
  • contaminants such as dust and smoke
  • strong magnetic fields
  • moisture and humidity
  • areas with mechanical vibrations
  • fluorescent lamps or objects that reflect light and unstable light sources
  • temperatures below -30° C (-22° F) and above 50° C (122° F).

To avoid electrical shock and to preserve the product warranty, DO NOT disassemble the camera. Refer servicing to qualified personnel only.

POWER SUPPLY

This camera accepts PoE power.
Ensure the supplied voltage meets the power consumption requirements of this camera (6W) before powering the camera on. Incorrect voltage may cause irreparable damage to the video camera and will effectively void the camera warranty.

CLEANING

  • For maximum optical clarity, the camera dome or lens must remain clean. Use a soft, dry cloth to remove finger prints or dust from the dome cover.
  • Use a blower to remove dust from the lens.
  • Do not use volatile solvents such as alcohol, benzene, or thinners, as they may damage the surface finishes.

PACKAGE CONTENTS

Ensure that the items received match those listed on the order form and the packing slip. In addition to this manual and a fully assembled camera, the dome camera packing box includes:

i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera -
fig1

A. Surface Mount template x1
B. Round Head Screw (Tapping Type) x4
C. Plastic Anchor x4
D. Standard RJ45 Connector x2
E. Hex bit x1
F. Rubber plug x1 (block the camera’s side cable opening in surface installations where the cable is routed upwards instead of through the side).”
Scan this QR code or visit ftp.i3international.com to view
and download AnnexxusConfigurationTool v1.8 (ACT) and
the full User Manual.

Contact our Technical Support team at: 1.877.877.7241 or [email protected] if you have any questions or concerns regarding camera installation or if you require
software services or support.

QR Code for Complete User Manual and ACT

CAMERA PARTS AND DEFINITIONS

i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera -
fig2

  1. Mounting holes (x4)

  2. RJ45 Ethernet PoE Port with waterproof RJ45 connector assembly.
    Insert an Ethernet cable into the port for network connection as well as PoE (Power over Ethernet) power. To maintain water-resistant rating in outdoor installations, make sure to use the included waterproof RJ45 Connector assembly.

  3. Dome cover

  4. Screws securing the dome cover to camera module (x4, hex, silver)

  5. Dome bubble

  6. Reset pinhole. Press for 10 seconds to restore camera settings to factory defaults.

  7. MicroSD Card slot for on-camera video storage. (MicroSD card sold separately).

  8. Cable side opening for surface installations. Block with the provided rubber plug (F) if not using.

  9. Tilt bracket with two locking screws. Tilt to adjust lens angle and re-tighten screws as needed when done.

  10. IR board (covered by the black masking plate)

  11. Camera lens.

3-AXIS LENS POSITIONING

Important: Do not over-rotate the camera lens assembly beyond the stop point to prevent twisted, disconnected, or broken internal cables/ components.
Note : To rotate the lens, tilt the lens assembly first and use the finger grooves to rotate the assembly.

| i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera -
fig4
---|---

3-axis Range Limitations:
Pan range: 355°
Rotate range: 355°
Tilt range: 67°

SURFACE INSTALLATION

Start by preparing the mounting surface. Based on installation location and surface type,supplied screws and anchors may not be adequate.
For pendant or horizontal wall-mounting, purchase the back box (i3 part numbers: B77 and B77 V2) and use a 3/4” NPT pipe or DB60, respectively. Surface installation can be completed without a back box.
Note : After installing the camera, your network camera must be accessible from your local network (LAN).

i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera -
fig5

To complete a surface mount installation:

  1. Attach the supplied mounting template to the mounting surface.

  2. Drill 4 holes, as marked on the template, insert 4 supplied anchors into the holes.

  3. Drill the conduit hole for the camera cable, if routing the cable upwards, and cover the cable exit hole with the rubber plug (F). (If routing the cable sideways, through the cable exit opening, do not drill the conduit hole.)

  4. Use the provided hex bit to loosen four screws securing the dome bubble to camera housing.

  5. Gently pull the dome bubble downwards. The dome bubble is attached to the camera by the safety rubber band.

  6. Feed the camera cable either through the cut conduit hole or through the side cable opening.

  7. Use four tapping screws provided to secure the camera to the prepared mounting surface.

  8. Adjust the lens angle by panning, tilting and rotating the lens assembly. Do not over-rotate the camera lens beyond the stop point to avoid damage to the camera.
    Note that in order to rotate the lens assembly, it needs to be in the tilted position, to expose the finger grooves.

  9. Once the desired view is achieved, replace the camera dome bubble and re-tighten 4 silver screws securing the dome bubble to the camera base.

WATERPROOF RJ45 ASSEMBLY

To prevent the corrosion of the RJ45 connector and to maintain the camera warranty, use the RJ45 waterproof assembly attached to the camera, as shown in the diagram
below.i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera -
fig6

  1.  Twist off the RJ45 waterproof assembly from the RJ45 connector.
  2. Feed the CAT5e/6 cable through the opening in the connector and crimp it using the standard RJ45 connector provided.
  3. Plug the crimped CAT5e/6 cable into the RJ45 connector on the camera and twist the waterproof assembly on to re-attach it.

Supported mounting options

See the table below for additional mounting options supported by M77 camera series. Compatible Mounting Accessories:
B77 V2 – back box for pendant installations
DB60 – goose-neck bracket
DB60CPM – corner/pole mount kit (use with DB60)

Mounting Type Additional Accessories required

Drywall / block wall mount
Surface mount (E.g. drop ceiling tile)| None
Pendant Mount
Electrical (Round/Hex, Single Gang) Box| B77 V2
Horizontal Wall Mount| B77 V2 + DB60
Pole Mount / Corner Mount| B77 V2 + DB60 + DB60CPM

ACTIVATING CAMERA, CHANGING IP ADDRESS in ACT

To activate and secure access to your camera, you must first set the password for the administrative user account (i3admin).
IMPORTANT : Your camera will remain inactive and inaccessible until administrative password is set.

Activate your Annexxus M77 camera by setting administrative password:

  1. Connect your Annexxus M77 camera to the Gigabit switch.

  2. On your i3 NVR, launch i3 Annexxus Configuration Tool (ACT) v.1.8 or higher.
    You can download and install the latest ACT installation package from i3 website: https://i3international.com/download

  3. In the model drop-down list, select M77.
    Security status will say “inactive”.i3 INTERNATIONAL M77R2 5MP Infrared Mini
Outdoor IP Dome Camera - fig8

  4. In the Global Camera Settings, click Set Password

  5. In the Set password window, enter the new password in the Password and Confirm fields. Follow secure password guidelines. Click OK. The new administrative password will be assigned to the camera and the Security status will change to “active”.
    Change your M77 camera’s default IP Address:
    Note : Your i3 NVR must have a valid IP address (not APIPA)

  6. In Annexxus Configuration Tool, select your M77 camera in the list.

  7. Uncheck “Default Account” and enter “i3admin” into Username field and the new administrative password (set in Step 6) into Password field.

  8. Enter the new IP address and Subnet Mask under Device(s) Communication Update and click Update.i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera - fig10Camera’s default IP address: 192.168.0.16.
    Camera’s default Subnet mask address: 255.255.255.0.
    Default User name: i3admin

  9. Wait a few moments for a “Success” message in the Result field.

  10. Repeat Steps 7-9 for all detected M77 cameras in the ACT until each camera has a unique IP address.

  11. To confirm your camera’s new IP address, click the IE icon next to each camera . In the IE browser, enter administrative Username (i3admin) and (new) Password and click LOGIN. Annexxus camera interface will be displayed in the Internet Explorer window. You should be able to see the camera image on the screen. If you do not see the camera image on the screen, call i3 International technical support team for troubleshooting tips: 1.877.877.7241i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera - fig11

ADDING CAMERA TO i3 PRO SETUP v7

  1. Launch the i3 Pro Setup from the Desktop or from the SRX-Pro Monitor.i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera - fig12

  2. In the IE browser, click Continue to this website.
    x ‘ Continue to this website (not recommended).

  3. Enter your administrator Username and Password and click LOGINi3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera -icon1

  4. Click on the Add tile.

  5. All cameras recognized by i3’s GiPi and ONVIF will be shown in the UNASSIGNED CAMERAS tab.

  6. Select one or more M77 cameras with the same login credentials and click
    LOGINi3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera
-icon1

  7. Enter camera’s Username and the Password (configured in the previous section) and click SAVE
    Login status for your device must now show the green checkmark .
    Note: Devices with “Login failed” status will not be added.

  8. Click ADD . Your IP devices have been added to i3 Pro Setup and are recording based on Sensor + Motion schedule.

Change resolution and frame rate for each camera in the List section of the i3 Pro Setup.

1.866.840.0004
www.i3international.com

Documents / Resources

| i3 INTERNATIONAL M77R2 5MP Infrared Mini Outdoor IP Dome Camera [pdf] User Manual
M77R2, 5MP Infrared Mini Outdoor IP Dome Camera, Outdoor IP Dome Camera, IP Dome Camera, 5MP Infrared Mini Camera, Camera
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

i3 INTERNATIONAL User Manuals

Related Manuals