i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera User Manual

June 3, 2024
i3 INTERNATIONAL

User Manual
Ax88
12MP Infrared Outdoor IP 360-degree Fisheye Camera
Rev. 220708

Thank you for purchasing i3 International’s Ax88 Fisheye IP dome camera.
Ax88 is equipped with a fisheye 1.97mm @ F2.3 lens and supports h.265 codec compression.
Note: Ax88 supports h.265 codec, but is shipped pre-set to h.264 to facilitate backward compatibility to the earlier versions of SRX-Pro (below v7).
To change the codec to h.265 in the camera’s web settings > Setup > Video > Video Configuration > Video Stream.

SAFETY

When installing your Ax88 camera be sure to avoid:

  • excessive heat, such as direct sunlight or heating appliances
  • contaminants such as dust and smoke
  • strong magnetic fields
  • moisture and humidity
  • areas with mechanical vibrations
  • fluorescent lamps or objects that reflect light and unstable light sources
  • temperatures below -40° C (-40° F) and above 50° C (122° F).
    To avoid electrical shock and to preserve the product warranty, DO NOT disassemble the camera. Refer servicing to qualified personnel only.

POWER SUPPLY

This camera accepts PoE power.
Ensure the supplied voltage meets the power consumption requirements of this camera (15W) before powering the camera on. Incorrect voltage may cause irreparable damage to the video camera and will effectively void the camera warranty.

CLEANING

  • For maximum optical clarity, the camera dome or lens must remain clean.
    Use a soft, dry cloth to remove fingerprints or dust from the dome cover.

  • Use a blower to remove dust from the lens.

  • Do not use volatile solvents such as alcohol, benzene, or thinners, as they may damage the surface finishes.

PACKAGE CONTENTS

  • Ensure that the items received match those listed on the order form and the packing slip. In addition to this manual and a fully assembled camera, the dome camera packing box includes:
    A. Surface Mount template x1
    B. Round Head Screw (Tapping Type) x4
    C. Plastic Anchor x4
    D. Torx bit
    E. Standard RJ45 Connector x2
    F. Sealed desiccant i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP
360-Degree Fisheye Camera - fig

WATERPROOF RJ45 ASSEMBLY

To prevent the corrosion of the RJ45 connector and to maintain the camera warranty, use the RJ45 waterproof assembly attached to the camera, as shown in the diagram below.

  1. Twist off the RJ45 waterproof assembly from the RJ45 connector.
  2. Feed the CAT5e/6 cable through the opening in the connector and crimp it using the standard RJ45 connector provided.
  3. Plug the crimped CAT5e/6 cable into the RJ45 connector on the camera and twist the waterproof assembly on to re-attach it.

i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera -
Waterproof

Scan this QR code or visit ftp.i3international.com to view and download AnnexxusConfigurationTool v1.9 (ACT).
Contact our Technical Support team at: 1.877.877.7241 or support@i3international.com if you have any questions or concerns regarding camera installation or if you require
software services or support.

i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera -
QR https://ftp.i3international.com

CAMERA PARTS AND DEFINITIONS

i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera -
CAMERA

  1. RJ45 Ethernet PoE Port with waterproof RJ45 connector assembly. Insert an Ethernet cable into the port for network connection as well as PoE (Power over Ethernet) power. To maintain a water-resistant rating, make sure to use the included waterproof RJ45 Connector assembly.
  2. MicroSD Card slot for on-camera video storage (sold separately).
  3. Mounting holes (x3)
  4. Reset the pinhole. Press for 10 seconds to restore camera settings to factory defaults.
  5. Light sensor (do not block or obstruct)
  6. IR LED lights, 49ft/15m (x6)
  7. Dome cover screws (torx x3)

SURFACE INSTALLATION

Start by preparing the mounting surface. Based on installation location and surface type, supplied screws and anchors may not be adequate.
For pendant or horizontal wall-mounting, purchase the back box (i3 part number: B88) and use a 3/4” NPT pipe or DB60, respectively. Surface installation can be completed without a back box.
Note: After installing the camera, your network camera must be accessible from your local network (LAN).
To complete a surface mount installation:

  1. Attach the supplied mounting template to the mounting surface.

  2. Drill 3 holes, as marked on the template, and insert 3 supplied anchors into the holes.

  3. Drill the conduit hole for the camera cable, if routing the cable upwards. If routing the cable sideways, through the cable exit opening, do not drill the conduit hole.

  4. Remove the dome cover. Use the Torx bit provided to loosen three screws, lift upwards and set the dome cover aside.

  5. Open the desiccant package (provided) and replace the desiccant already installed on the camera (Fig. 4)

  6. Feed the camera cable through the cut conduit hole or through the side cable opening. i3-TRNG-CAMS-Ax88.indd
    QUICK START GUIDE

  7. Use the tapping screws to secure the camera to the prepared mounting surface. (Fig. 5)

  8. Replace the camera cover.

  9. Use the torx bit provided to re-tighten the dome cover screws (x3).

MOUNTING OPTIONS
Compatible Mounting Accessories: B88 – back box for pendant installations DB60 – goose-neck bracket DB60CPM – corner/pole mount kit (use with DB60)

Mounting Type Accessories required
Wall mount (e.g. drywall); Surface mount (e.g. drop ceiling) None
Pendant Mount; Electrical Gang Box (round/hex/single) B88
Horizontal Wall Mount B88 + DB60
Pole Mount / Corner Mount B88 + DB60 + DB60CPM

ACTIVATE THE CAMERA IN THE ACT
Camera’s default IP address: is 192.168.0.16.
Camera’s default Subnet mask address: 255.255.255.0.
Default User name: i3admin
IMPORTANT: Before adding your camera to SRX-Pro, set the administrative password and unique camera IP. Your camera will remain inactive and inaccessible until the administrative password is set.
Setting administrative password:

  1. Connect your Annexxus Ax88 camera to the Gigabit switch.

  2. Launch i3 Annexxus Configuration Tool (ACT) v.1.9.2.0 or higher.
    Download and install the latest ACT installation and GiPi package from i3 website, if needed: https://i3international.com/download

  3. In the model drop-down list, select Ax88. Security status will say “inactive”.i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera - fig 1

  4. In the Global Camera Settings, click Set Password

  5. In the Set password window, enter the new password in the Password and Confirm fields. Follow secure password guidelines. Click OK.
    The new administrative password will be assigned to the camera and the Security status will change to “active”.

SET CAMERA IP IN ACT
Note: Your i3 Server must have a valid IP address (not APIPA) Set your camera’s unique IP address:

  1. In Annexxus Configuration Tool, select your Ax88 camera in the list.
  2. Uncheck “Default Account” and enter “i3admin” into the Username field and the new administrative password into the Password field.
  3. Enter the new IP address and Subnet Mask and click Update.i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera - fig 3
  4. Wait a few moments for a “Success” message in the Result field.
  5. Repeat Steps 1-3 for all detected Ax88 cameras in the ACT until each camera has a unique IP address.
  6. To confirm your camera’s new IP address, click the IE icon in the ACT.

In the IE browser, enter the administrative Username (i3admin) and (new) Password and click LOGIN. The camera web interface will be displayed in the Internet
Explorer window. Download and run the plug-in, if prompted.
If you are unable to see live video on the screen, call i3 International technical support team for troubleshooting tips: 1.877.877.7241
Ax88 12MP IP Fisheye Camera
CHANGE CAMERA MODE

Ax88 Fisheye camera supports two display modes:

  • Mode 1 (default): Fisheye only
  • Mode 2: Fisheye + 4x ePTZ
  • Mode 3: Fisheye + Panorama + 3x ePTZ

Switching to Mode 2 or Mode 3 (optional):

  1.   In the camera’s web interface, click on the Setup > Video > Video Configuration option.
  2.  In the Video Stream menu, click on the Mode drop-down and select “Mode 2” or “Mode 3”i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera - fig6
  3. Click Save. Wait until the camera’s Live view refreshes.

CHANGE COMPRESSION

Ax88 is shipped pre-set to h.264 codec, to facilitate backward compatibility for the earlier versions of SRX-Pro (below v7).
To enable h.265 codec,

  1. In the camera’s web interface, click on Setup > Video > Video Configuration.
  2. Change the codec to H.265 for both the Main and Sub Streams and click Save.
  3. Repeat for Channels 2-5 (if applicable). Click Save after changing the settings for each channel. Wait until the camera’s Live view refreshes.i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera - fig7

ADD CAMERA TO SRX-Pro PRO SETUP v7

  1. Launch the SRX-Pro Setup from the Desktop or from the SRX-Pro Monitor.i3 INTERNATIONAL Ax88 12MP Infrared Outdoor IP 360-Degree Fisheye Camera - fig8

  2. In the IE browser, click Continue to this website.

  3. Enter your administrator Username and Password and click LOGIN

  4. Click on the Add tile.

  5. If using SRX-Pro v.7.1, find your Ax88 camera in the list of UNASSIGNED CAMERAS. You may need to click REFRESH.
    If using SRX-Pro v.7.2 and above, click SEARCH and wait until your Ax88 camera is discovered.

  6. Select one or more Ax88 cameras with the same login credentials and click LOGIN

  7. Enter the camera’s Username and Password (configured in the previous section) and click SAVE
    The login status for your device must now show the green check mark .
    Note: Devices with “Login failed” status will not be added.

  8. Click ADD . Your IP devices have been added to i3 SRX-Pro Setup and are recording based on the Sensor + Motion schedule.
    Change the resolution and frame rate for each camera and channel in the List section of the i3 SRX-Pro Setup.

1.866.840.0004
www.i3international.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

i3 INTERNATIONAL User Manuals

Related Manuals