BEGA 85 244 Pole Top Luminaire Floodlight LED Instruction Manual

August 9, 2024
BEGA

BEGA 85 244 Pole Top Luminaire Floodlight LED

BEGA 85 244 Pole Top Luminaire Floodlight LED

Dimension

Dimension

Application

Pole-top luminaire with asymmetrical flat beam light distribution.
The asymmetrical and flat beam light distribution is suitable especially for the illumination of streets according to DIN EN 13201.
For mounting heights 4000-5000mm.

Product Description

Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Clear safety glass
Silicone gasket
Reflector made of pure anodised aluminium
Attack angle adjustable in steps
of 10° up to +90°
For pole top ø 76mm
Slip fitter insert depth 95mm
Connecting cable X05BQ-F 5G1mm²
Cable length 5m
BEGA Ultimate Driver®
Complies with flicker requirements in
accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-276 V
DALI controllable
Number of DALI addresses: 1
A basic isolation exists between power cable
and control line
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without
switching off the luminaire
Safety class I
Protection class IP 66
Dust-tight and protection against strong water
jets
Impact strength IK10
Protection against mechanical
impacts < 20 joule
– Conformity mark
Horizontal wind catching area: 0.06 m²
This product contains light sources of energy
efficiency class(es) C

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.

Lamp

Module connected wattage 23.2 W
Luminaire connected wattage 25.8 W
Rated temperature ta=25 °C
Service life criteria 50000 h/L70

85 244K3

Module designation 2x LED-1564/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 4510 lm
Luminaire luminous flux 3711 lm
Luminaire luminous efficiency 143,8 lm/W

85 244K4

Module designation 2x LED-1564/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 4640 lm
Luminaire luminous flux 3818 lm
Luminaire luminous efficiency 148 lm/W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

Lead luminaire connecting cable into the pole and put on luminaire.
Align luminaire and fix it.
Torque = 12Nm.
The electrical connection of the luminaire must be made with the appropriate protection class and safety class using suitable connection terminals (not included in the scope of delivery) on the luminaire power supply cable.
We recommend you use BEGA connection boxes for this purpose.
Note correct configuration of the mains supply cable. The earth conductor is connected at the green-yellow , the phase to the brown (L), and the neutral conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.

Adjustment of beam direction:
Loosen acorn nut M 10.
Make luminaire adjustment.
Tighten the acorn

Please note:

Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified
persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced. Close the luminaire.

Accessories

Tapered aluminium poles,
lacquered with access door and C-clamp
70 914 Pole with anch.section H 4000 mm
70 725 Pole with anch.section H 4500 mm
70 915 Pole with anch.section H 5000 mm
70 791 Pole with baseplate H 4000 mm
70 792 Pole with baseplate H 4500 mm
70 794 Pole with baseplate H 5000 mm

Please see the instructions for use of the luminaire poles for suitable connection boxes.

Spares

LED power supply unit DEV-0312/700
LED module 3000 K LED-1564/830
LED module 4000 K LED-1564/840
Reflector 76 001 088
Gasket 83 000 924

Customer Support

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals