BEGA 11 002 949 Wall Luminaire Instruction Manual
- July 27, 2024
- BEGA
Table of Contents
Wall luminaire for indoor use
Technical amendments reserved
23 259.4
Instructions for use
Application
Wall luminaire · indoor luminaire made of handblown opal glass and metal
housing, for all lighting tasks in interior applications.
They are ideal for places where a soft and uniform lighting distribution is
required.
Luminaire with a high protection class.
Product description
Luminaire made of Aluminium, finish Colour velvet brass Hand-blown opal glass
Two elongated mounting holes Width 6 mm · 450 mm spacing
Insulating housing with cable entry for mains supply cable up to ø 10,5 mm,
max. 3 x 1,5°
Connection terminal 2.5°
Earth conductor connection
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1 LED power supply unit
220-240 V x 0≂50-60 Hz DC 198-280 V
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components Safety
class I
Protection class IP 44
Protected against granular foreign bodies
≥ 1 mm and splash water
Impact strength IK02
Protection against mechanical impacts < 0.2 joule
– Safety mark
– Conformity mark
Weight: 2.6 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
Lamp
Module connected wattage | 19.2 W |
---|---|
Luminaire connected wattage | 22.4 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 35 °C |
23 259.4 K3
Module designation| 3x LED-0425/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 3165 lm
Luminaire luminous flux| 2170 lm
Luminaire luminous efficiency| 96,9 lm / W
23 259.4 K4
Module designation| 3x LED-0425/940
Colour temperature| 4000 K
Colour rendering index| CRI > 90
Module luminous flux| 3345 lm
Luminaire luminous flux| 2293 lm
Luminaire luminous efficiency| 102,4 lm / W
Insulation housing
Installation
For mounting and dismantling please keep a minimum distance of 450 mm between
the removable cap and the wall.
LEDs are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Open luminaire:
Loosen knob, remove cap and glass.
Drill mounting holes into the mounting surface – spacing 450 mm.
For the mains supply connecting open the insulation housing – pull open –
strip mains supply cable max. 15 mm and lead it into the insulation housing –
see sketch.
Make earth conductor connection and electrical connection.
Connect both parts of the insulation housing until they audibly engage.
The outer coating of the cable has to be fully enclosed by the compression
nipple.
Fix luminaire with enclosed or any other suitable fixing material onto the
mounting surface.
Remove bubble wrap underneath LED module.
Place glass into luminaire housing, close luminaire with the cap and screw in
knob into the cap.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Loosen lateral knob, remove cap and take out glass.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Insert glass into luminaire housing, close luminaire with the cap and screw in
knob into the cap.
Spares
Spare glass | 11 002 949 .1R G |
---|---|
LED power supply unit | DEV-0352/1000 |
LED module 3000 K | LED-0425/930 |
LED module 4000 K | LED-0425/940 |
Gasket | 83 001 179 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com