BEGA 24 916 Ceiling and Wall Luminaire
INSTRUCTION MANUAL
Ceiling and wall luminaire
Instructions for use
Application
Unshielded luminaire with high protection class for installation under
ceilings and on walls.
A luminaire made of die cast aluminium and impact resistant synthetic diffuser
made of BEGA NeoGlass®.
For interior and exterior lighting applications.
Product description
Luminaire made of aluminium alloy and stainless steel
BEGA Unidure® coating technology Colour graphite
Impact resistant synthetic diffuser, BEGA NeoGlass® · diffuse white Silicone
gasket 2 mounting holes ø 5.2 mm
Distance apart 210 mm 2 cable entries for through-wiring of mains supply cable
ø 7-10.5 mm
Connection terminal 2.5@
Earth conductor connection Complies with flicker requirements in accordance
with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit
220-240 V x 0/50-60 Hz
DC 170-276 V
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components Safety
class I
Protection class IP 65
Dust-tight and protection against water jets c – Conformity mark
This product contains light sources of energy efficiency class(es) B
Lamp
Module connected wattage 11.6 W
Luminaire connected wattage 13.5 W
Rated temperature ta = 25 °C
Service life criteria 50 000 h / L70
24 916 K3
Module designation LED-1639/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 2440 lm
Luminaire luminous flux 1300 lm
Luminaire luminous efficiency 96,3 lm / W
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to
the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against
e. g. transients, etc. we recommend separate overvoltage protection
components.
You can find them on our website at
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo screws.
Remove luminaire top and polycarbonate diffuser with gasket.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied. Make the earth conductor connection
and the electrical connection.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire.
Make sure that gasket is positioned correctly. Insert polycarbonate diffuser
with gasket and luminaire top.
Tighten the screws evenly.
Cleaning · Maintenance
Clean dirt and debris from the luminaire regularly with a clean, soft, lint-
free cloth that is kept damp throughout the cleaning.
If possible, please use water for this, adding a little commercial dishwashing
detergent.
For lacquered surfaces we recommend the use of BEGA Lacquer Care Set 71 179.
Cleaning agents containing solvents and high-pressure cleaners are unsuitable
for cleaning and maintenance.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Synthetic cover 15 000 860
LED power supply unit DEV-0341/350
LED module 3000 K LED-1639/830
Gasket 83 000 514
Specifications:
- Lamp Module connected wattage: 11.6 W
- Luminaire connected wattage: 13.5 W
- Colour temperature: 3000 K
- Colour rendering index (CRI): > 80
- Module luminous flux: 2440 lm
- Luminaire luminous flux: 1300 lm
- Luminaire luminous efficiency: 96.3 lm / W
Installation:
- Undo screws and remove the luminaire top and polycarbonate diffuser with gasket.
- Lead the mains supply cable through the cable entry of the luminaire base.
- Fix the luminaire base onto the mounting surface using the provided fixing material and gasket rings.
- Make the earth conductor connection and the electrical connection.
- To ensure maximum service life of electrical components, place the enclosed desiccant pouch in the luminaire before closing it.
- Position the gasket correctly and insert the polycarbonate diffuser with gasket and luminaire top. Tighten the screws evenly.
FAQ:
Q: Can I touch the LED directly during installation?
A: It is recommended to avoid touching the light output opening of the LED directly during installation or relamping to prevent damage to the high- quality electronic components.
Q: Where can I find spare parts for the luminaire?
A: The synthetic cover, LED power supply unit, LED module 3000 K, and gasket are available as spares. Please refer to the following part numbers:
- Kunststoffabdeckung (Synthetic cover): 15 000 860
- LED-Netzteil (LED power supply unit): DEV-0341/350
- LED-Modul 3000 K (LED module 3000 K): LED-1639/830
- Dichtung (Gasket): 83 000 514