BEGA 24 912 Ceiling and Wall Luminaire Instruction Manual
- July 27, 2024
- BEGA
Table of Contents
03.24 Technical amendments reserved
24 912
Ceiling and wall luminaire
Instructions for use
Application
Unshielded luminaire with high protection class for installation under
ceilings and on walls. A luminaire made of die cast aluminium and impact
resistant synthetic diffuser made of BEGA NeoGlass ® .
For interior and exterior lighting applications.
Product description
Luminaire made of aluminium alloy and stainless steel BEGA Unidure ® coating
technology Colour graphite Impact resistant synthetic diffuser, BEGA NeoGlass
® · diffuse white
Silicone gasket 2 mounting holes ø 5 mm Distance apart 195 mm 2 cable entries
for through-wiring of mains supply cable ø 7-10.5 mm Connection terminal 2.5@
Earth conductor connection Complies with flicker requirements in accordance
with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V x 0/50-60 Hz
DC 170-276 V BEGA Thermal Switch ® Temporary thermal shutdown to protect
temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets c ****– Conformity mark
This product contains light sources of energy efficiency class(es) B
Lamp
Module connected wattage | 11.6 W |
---|---|
Luminaire connected wattage | 13.5 W |
Rated temperature | ta = 25 °C |
Service life criteria | 50 000 h / L 70 |
24 912 K3
Module designation | LED-1633/830 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 2440 lm |
Luminaire luminous flux * | 1650 lm |
Luminaire luminous efficiency * | 122,2 lm / W |
- preliminary data
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71 320.
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Undo screws.
Remove luminaire top and polycarbonate diffuser with gasket.
Lead the mains supply cable through the cable entry of the luminaire base.
For wall installation note the position of application “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied. Make the earth conductor connection
and the electrical connection. In order to guarantee the maximum service life
of the electrical components, the enclosed desiccant pouch must be placed in
the
luminaire. Remove the desiccant pouch from the foil packaging and place it in
the position marked by the red information label immediately before finally
closing the luminaire. Make sure that gasket is positioned correctly. Insert
polycarbonate diffuser with gasket and luminaire top. Tighten the screws
evenly.
Cleaning · Maintenance
Clean dirt and debris from the luminaire regularly with a clean, soft, lint-
free cloth that is kept damp throughout the cleaning.
If possible, please use water for this, adding a little commercial dishwashing
detergent.
For lacquered surfaces we recommend the use of BEGA Lacquer Care Set 71 179.
Cleaning agents containing solvents and highpressure cleaners are unsuitable
for cleaning and maintenance.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Synthetic cover | 15 000 856 |
---|---|
LED power supply unit | DEV-0341/350 |
LED module 3000 K | LED-1633/830 |
Gasket | 83 000 514 |
BEGA Gantenbrink-Leuchten KG
Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com
Documents / Resources
| BEGA
24 912 Ceiling and Wall
Luminaire
[pdf] Instruction Manual
24912, 24912K3, 24 912 Ceiling and Wall Luminaire, 24 912, 24 912 Luminaire,
Ceiling and Wall Luminaire, Ceiling Luminaire, Wall Luminaire, Luminaire
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>