Application
Unshielded luminaire with high protection class for installation under ceilings and on walls. A luminaire made of die cast aluminium and impact resistant synthetic diffuser made of BEGA NeoGlass ® .
For interior and exterior lighting applications.
Product description
Luminaire made of aluminium alloy and stainless steel BEGA Unidure ® coating technology Colour graphite Impact resistant synthetic diffuser, BEGA NeoGlass ® · diffuse white
Silicone gasket 2 mounting holes ø 5 mm Distance apart 195 mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm Connection terminal 2.5@ Earth conductor connection Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V x 0/50-60 Hz
DC 170-276 V BEGA Thermal Switch ® Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets c ****– Conformity mark
This product contains light sources of energy efficiency class(es) B

Lamp

Module connected wattage 11.6 W
Luminaire connected wattage 13.5 W
Rated temperature ta = 25 °C
Service life criteria 50 000 h / L 70

24 912 K3

Module designation LED-1633/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 2440 lm
Luminaire luminous flux * 1650 lm
Luminaire luminous efficiency * 122,2 lm / W
  • preliminary data

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo screws.
Remove luminaire top and polycarbonate diffuser with gasket.
Lead the mains supply cable through the cable entry of the luminaire base.
For wall installation note the position of application “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied. Make the earth conductor connection and the electrical connection. In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the
luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Make sure that gasket is positioned correctly. Insert polycarbonate diffuser with gasket and luminaire top. Tighten the screws evenly.

Cleaning · Maintenance

Clean dirt and debris from the luminaire regularly with a clean, soft, lint- free cloth that is kept damp throughout the cleaning.
If possible, please use water for this, adding a little commercial dishwashing detergent.
For lacquered surfaces we recommend the use of BEGA Lacquer Care Set 71 179.
Cleaning agents containing solvents and highpressure cleaners are unsuitable for cleaning and maintenance.

Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

Synthetic cover 15 000 856
LED power supply unit DEV-0341/350
LED module 3000 K LED-1633/830
Gasket 83 000 514

BEGA Gantenbrink-Leuchten KG
Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 24 912 Ceiling and Wall Luminaire [pdf] Instruction Manual
24912, 24912K3, 24 912 Ceiling and Wall Luminaire, 24 912, 24 912 Luminaire, Ceiling and Wall Luminaire, Ceiling Luminaire, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals