BEGA 85 187 Garden Floodlight Instruction Manual

July 30, 2024
BEGA

85 187 Garden Floodlight
Instruction Manual

85 187 Garden Floodlight

Technical amendments reserved
Garden floodlight BEGA UniLink® Play

Instructions for use

Application
Portable garden floodlight BEGA UniLink Play
with earth spike and 2 m connecting cable with plug connector.
For the effective illumination of plants and smaller trees or objects in private gardens.
Connecting the floodlight requires a power supply unit (71 321), which must be ordered separately.
In addition, by combining with the Smart Link 71 327, the floodlight and other UniLink Play luminaires of this power path can be conveniently switched and dimmed via the free BEGA Smart app.
BEGA UniLink®  Play is a system for smart garden lighting that is controlled via app, remote control or automation.
All connection cables and components are installed above ground in the area of use.
Thanks to the IP 67 standard, they are weatherresistant year-round and highly durable. After successful electrical connection, they can be configured in the BEGA Smart app.

Lamp|
---|---
Module connected wattage| 2.9 W
Luminaire connected wattage| 3.6 W
Rated temperature| ta= 25 °C
Ambient temperature| ta max = 65 °C
Voltage| 48 V = DC
85 187 K3

Module designation| LED-1389/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 525 lm
Luminaire luminous flux| 392 lm
Luminaire luminous efficiency| 108,9 lm / W

Light technique
Broad spread light distribution.
Half beam angle 66°Product description
Luminaire housing made of cast aluminiumBEGA Unidure® coating technology
Earth spike made of glass fibre reinforced synthetic material
Colour graphite
Polymer lens
Swivel range -90°/+90°
Tool-free plug-on shield made of synthetic material, rotation range -60°/+60° 2 m connecting cable with BEGA UniLink® Play plug
Protection class IP 67 when plugged in and screwed in place
Luminaire housing:
Safety class
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical impacts < 2 joule
– Conformity mark
Weight: 0.25 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Installation

Press the luminaire with earth spike vertically into the soil until stability is achieved. If necessary, compact soil around the earth spike.
The maximum wattage for the luminaires connected to the power supply unit 71 321 is 100 W.
When the power supply unit is fully loaded, the maximum cable length between the luminaire and the power supply unit must not exceed 100 m.
Insert the plug of the floodlight into the plug contact of the power supply unit, Smart Link, distribution box or extension cable and handtighten.
Do not use tools for the tightening or loosening of the screw connections. Adjust the floodlight:
Undo hexagon socket screws (wrench size 2 mm) and set the desired beam direction.
Tighten the hexagon socket screws evenly.

Cleaning · Maintenance

Clean dirt and debris from the luminaire regularly with a clean, soft, lint- free cloth that is kept damp throughout the cleaning.
If possible, please use water for this, adding a little commercial dishwashing detergent.
For lacquered surfaces we recommend the use of BEGA Lacquer Care Set 71 179.
Cleaning agents containing solvents and high pressure cleaners are unsuitable for cleaning and maintenance.

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories

71 321| BEGA UniLink® Play power supply unit
Primary: 220 V-240 V 50/60 Hz
Secondary: 48 V DC · 0-100 W
---|---
71 322| BEGA UniLink® Play
Extension cable 5 m
71 323| BEGA UniLink® Play
Extension cable 10 m
71 324| BEGA UniLink® Play
Extension cable 20 m
71 325| BEGA UniLink® Play
Five-way distribution box
71 326| BEGA UniLink® Play
Two-way distribution box
71 327| BEGA UniLink® Play Smart Link

For the accessories a separate instructions for use can be provided upon request.

Spares

Earth spike 16 006 608
Shield 16 006 693
LED module 3000 K LED-1389/830
Gasket 83 002 220

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com