BEGA 85 006 Floodlight Instruction Manual
- July 27, 2024
- BEGA
Table of Contents
42.21 · Technical amendments reserved
85 006
Floodlight
IP 65
- bottom
Instructions for use
Application
Floodlight with mounting box for permanent installation on a wall, under a
ceiling or on a pillar. For floodlighting plants, walls and other surfaces and
for various lighting tasks in the private sector.
Product description
Floodlight made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Clear safety glass
Reflector surface made of pure aluminium
Rotation range of floodlight 350°
Swivel range -15°/+90°
Mounting plate with 2 fixing
holes ø 4.8 mm · 35 mm spacing
1 cable entry for mains supply cable up to ø 10,5 mm
Connecting terminals and earth conductor terminal 2,5
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-280 V
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety mark
- Conformity mark
Weight: 0.8 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Lamp
Module connected wattage 6.1 W
Luminaire connected wattage 7.2 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 55 °C
85 006 K3
Module designation LED-1285/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 890 lm
Luminaire luminous flux 631 lm
Luminaire luminous efficiency 87,6 lm / W
Lighting technology
Wide beam light distribution
Half beam angle 50°
Installation
Undo hexagon socket head screws (wrench size 3 mm) at the mounting box and
remove mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection.
Make sure that gasket is positioned correctly. Place floodlight onto mounting
plate, adjust and fix it.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 3 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 2.5 Nm.
Cleaning • Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supply. Undo hexagon socket head cap
screws (torx drive T8) and disassemble end ring with glass, gasket and
reflector.
Replace LED module. Please follow the installation instructions for the LED
module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Screw the trim ring along with glass, gasket and reflector tightly on the
luminaire housing.
Spares
Spare glass 14 000 850
LED power supply unit DEV-0451/350
LED module 3000 K LED-1285/930
Reflector 76 002 089
Gasket mounting box 83 000 659
Gasket glass 83 001 652
BEGA Gantenbrink-Leuchten KG • Postfach 31 60 • 58689 Menden • info@bega.com • www.bega.com