BEGA 85 006 Floodlight Instruction Manual

July 27, 2024
BEGA

42.21 · Technical amendments reserved

85 006

Floodlight

IP 65

  1. bottom

Instructions for use


Application
Floodlight with mounting box for permanent installation on a wall, under a ceiling or on a pillar. For floodlighting plants, walls and other surfaces and for various lighting tasks in the private sector.

Product description
Floodlight made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Clear safety glass
Reflector surface made of pure aluminium
Rotation range of floodlight 350°
Swivel range -15°/+90°
Mounting plate with 2 fixing
holes ø 4.8 mm · 35 mm spacing
1 cable entry for mains supply cable up to ø 10,5 mm
Connecting terminals and earth conductor terminal 2,5
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-280 V
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– ­ Safety mark
­- Conformity mark
Weight: 0.8 kg
This product contains light sources of energy efficiency class(es) D

Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Lamp
Module connected wattage               6.1 W
Luminaire connected wattage           7.2 W
Rated temperature                     ta = 25 °C
Ambient temperature          ta max = 55 °C

85 006 K3
Module designation                        LED-1285/930
Colour temperature                                     3000 K
Colour rendering index                             CRI > 90
Module luminous flux                                   890 lm
Luminaire luminous flux                               631 lm
Luminaire luminous efficiency              87,6 lm / W

Lighting technology
Wide beam light distribution
Half beam angle 50°

Installation
Undo hexagon socket head screws (wrench size 3 mm) at the mounting box and remove mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection.
Make sure that gasket is positioned correctly. Place floodlight onto mounting plate, adjust and fix it.

Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 3 mm) and set the desired beam direction.
Tighten the joint screw.
Torque = 2.5 Nm.

Cleaning • Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
Disconnect the system from the power supply. Undo hexagon socket head cap screws (torx drive T8) and disassemble end ring with glass, gasket and reflector.
Replace LED module. Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Screw the trim ring along with glass, gasket and reflector tightly on the luminaire housing.

Spares

Spare glass                                  14 000 850
LED power supply unit       DEV-0451/350
LED module 3000 K           LED-1285/930
Reflector                                     76 002 089
Gasket mounting box                 83 000 659
Gasket glass                                83 001 652

BEGA Gantenbrink-Leuchten KG • Postfach 31 60 • 58689 Menden • info@bega.comwww.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals