BEGA 84 941 Compact Floodlight RGBW Instruction Manual
- July 26, 2024
- BEGA
Table of Contents
BEGA 84 941 Compact Floodlight RGBW
Specifications:
-
Product Name: Kompaktscheinwerfer RGBW Compact floodlight RGBW
Projecteur compact RGBW -
Material: Aluminium alloy
-
Control: DALI-controllable
-
Safety Class: I
-
Protection Class: IP 65 (Dust-tight and protection against water jets)
-
Impact Strength: IK07
Product Description:
This luminaire is a compact floodlight made of aluminum alloy with a DALI- controllable feature. It provides basic insulation between mains, temperature- sensitive components, and has safety class I with IP 65 protection against dust and water jets.
Installation Instructions:
- Secure screw connections to prevent loosening.
- Check the earth conductor connection.
- Adjust floodlight by undoing hexagon socket screw and hexagon nut.
- Ensure the electrical connection is strain-relieved with suitable connection terminals at the power supply cable.
- Connect the mains supply cable correctly to brown (L), blue (N), and green-yellow lead (1).
- Control cables are connected using the leads marked with DALI.
Safety Instructions:
The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should carry out installation and commissioning. The manufacturer does not accept liability for damage due to improper use or installation. Modifications should be done by authorized personnel.
Overvoltage Protection:
The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. For additional protection, consider separate overvoltage protection components available on the manufacturer’s website.
FAQ
Q: Can I operate the luminaire at full light output if control cables are not connected?
A: Yes, if the control cables are not used, the luminaire will operate at full light output.
Dimension
Instructions for use
Application
Compact floodlights with G½ connecting thread. The floodlight can be screwed on by the customer with any G½ female thread according to ISO 228 or with BEGA accessories. The floodlight can be controlled by DALI colour light control.
Product Description
-
Luminaire made of aluminium alloy, aluminium and stainless steel
-
BEGA Unidure® coating technology
-
Colour graphite or silver
-
Clear safety glass
-
Reflector surface made of pure aluminium
Rotation range of floodlight 350° Swivel range -20°/+90° -
Mounting bracket with G½ threaded connection
-
Thread length: 11mm
-
Connecting cable X05BQ-F 5G1mm²
-
Cable length 1m
-
BEGA Ultimate Driver®
-
Complies with flicker requirements in accordance with IEEE 1789,
-
DIN IEC/TR 63158, DIN IEC/TR 61547-1
-
LED power supply unit 220-240 x 0/50-60 Hz
-
DC 176-264 V
-
DALI-controllable
-
Number of DALI addresses: 1
-
Basic insulation is provided between the mains and control cables
-
BEGA Thermal Control®
-
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
-
Safety class I
-
Protection class IP 65
-
Dust-tight and protection against water jets
-
Impact strength IK07
-
Protection against mechanical
-
impacts < 2 joule
-
Safety mark
-
Conformity mark
-
Wind catching area: 0.027 m²
-
Weight: 2.6 kg
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory. G½ threaded connection torque = 40Nm. Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A). Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.
Adjust floodlight: Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 30 mm) and set the desired beam direction. Torque: Hexagon socket screw = 7 Nm Hexagon nut = 35 Nm Secure bolted connection Gß against loosening by tightening the hexagon socket screw (wrench size 2 mm) (see sketch B, C)
The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable. Note correct configuration of the mains supply cable. Make mains supply connection at the brown (L), blue (N) and green-yellow lead . The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.
Lamp
- Module connected wattage 34.8 W
- Luminaire connected wattage 38.6 W
- Rated temperature ta=25 °C
- Ambient temperature ta max=40 °C
- Module designation LED-1160/RGBW
- Colour temperature of the white LED 4000 K
- Luminaire luminous flux 2518 lm
- Luminaire luminous efficiency 65,2 lm/W
Lighting technology
- Wide beam light distribution
- Half beam angle 24°
- For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high-pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools. Disconnect the system from the power supply. Open the floodlight: Loosen the back locking pin (hexagon socket wrench size 2mm) in the trim ring. Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise. Replace LED module. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets. Defective glass must be replaced. Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other. Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.
Accessories
- 71281 Shield
- 71 286 Cylindrical shield
- 71 291 Optical filter flat beam
- 71 042 Adapter for installation on a pole
- 70 214 Pole cap for pole ø 48 mm
- 70 248 Pole cap for pole ø 60 mm
- 70 245 Mounting box
- 70 252 General fastener
- 70 280 Tube clamp G½
- 70 283 Screw clamp
- 70 379 Cross beam G½
- 70 889 Tension belt
For the accessories, separate instructions for use can be provided upon request.
Spares
- Trim ring graphite with glass 25 000 232
- Trim ring silver with glass 25 000 233
- LED power supply unit DEV-0357/200
- LED module LED-1160/RGBW
- Reflector 76 002 010
- Gasket housing 83 001 027
- Gasket trim ring 83 002 223
BEGA Gantenbrink-Leuchten KG
- Postfach 3160 · 58689 Menden
- info@bega.com