TOOLS YOU WILL NEED

  • Fresh clean unleaded gasoline (not included)

  • Funnel (included)

  • 4-stroke engine oil (included)

BEFORE STARTING

  1. install the lifting hook bracket and wheels

    • Install the lifting hook bracket
    • Insert axles through wheels, washers, and frame; secure with Hitchings
      Before Starting
  2. Connect the battery cables
    Before Starting

  3. . Add engine oil

    • Slowly add 4-cycle engine oil until full. Do not overfill.
      Before Starting
  4. Add gasoline or connect a fuel source

    • Gasoline – Unscrew gas cap and slowly add gasoline. Do not overfill.
      Before Starting

    • Propane – Connect the LPG/propane hose to a propane cylinder and the generator.
      Before Starting

    • Natural Gas – Connect the natural gas hose to a natural gas supply line and the generator.
      Before Starting

SELECTING THE FUEL SOURCE

  1. For gasoline, rotate the fuel selector switch to GAS.
    Selecting The Fuel Source

  2. For propane, rotate the fuel selector switch to LPG and open the propane cylinder valve.
    Selecting The Fuel Source

  3. For propane, rotate the fuel selector switch to NG (natural gas) and open the natural gas valve.
    Selecting The Fuel Source

STARTING PROCEDURE

  1. Make sure all loads are disconnected from the generator and select a fuel source.

  2. Push the battery switch to the ON positioStarting Procedure

  3. For remote start, push and hold the start button on the key fob for two seconds
    Starting Procedure

  4. For push button start, push and hold the engine START/STOP button for two seconds
    Starting Procedure

  5. Make sure breakers are ON and connect loads to the control panel receptacles

SHUTDOWN PROCEDURE

  1. Make sure all loads are disconnected from the generator

  2. Turn the fuel selector switch to OFF  and stop the flow of fuel by cylinder valve or the valve on the natural gas hose.
    Starting Procedure

  3. Press and hold the engine START/STOP button or the stop button on the key fob for one second to stop the generator
    Starting Procedure

  4. Push the battery switch to the off position
    Starting Procedure

GENERATOR MECHANICAL SPECIFICATIONS

M o del Number| Running Watts| Peak Watts| Fuel Tank Size (L/G)| Rated Speed (RPM)| Ignition Type| Engine Disp (cc| Oil Capacity (L)| Oil Type| TH D
---|---|---|---|---|---|---|---|---|---
WGenl4500TFc| 14500

Gasoline

| 18000

Gasoline

| 36/9.5| 3600| TCI| 713| 1.6| 10W30| ≤ 23%

MAINTENANCE SCHEDULE

Following the maintenance schedule is important to keep the generator in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals. Refer to the Maintenance section in the Owners Manual to find out how to properly perform maintenance.

TABLE 1: MAINTENANCE SCHEDULE

Maintenance Item| Before Every Use| After First 25 Hours or First Month of Use| After 50 Hours of Use or Every 6 Months| After 100 Hour of Use or Every 6 Months| After 300 Hours of
Use or Every Year
---|---|---|---|---|---
Engine Oil| Check Level| Change1| Change| –| –
Air Filter| –| –| Clean2| –| Replace
Spark Plug| –| –| –| Check/Clean| Replace
Spark Arrestor| –| –| –| Check/Clean| –
Fuel Filter| –| –| –| Replace3| –
Valve Clearance| –| –| –| Inspect/Adjust3| –

  1. Change oil every month when operating under heavy load or in high temperatures.
  2. Clean more often under dirty or dusty conditions.
  3. Recommended service by authorized Westinghouse dealer.

ENGINE OIL

Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL. Synthetic oil is an acceptable substitute for conventional oil.

Engine Oil

SPARK PLUG REPLACEMENT

Westinghouse Model Number| Torch| Torch| Torch| Autolite
---|---|---|---|---
WGen14500TFc| GAS5357| BPR6HS| BPR6HS| 284

  DANGER


Using a generator indoors CAN KILL YOU IN MINUTES  Generator
exhaust contains carbon monoxide. This is a poison you cannot see or smell

NEVER use inside a home or garage, EVEN IF doors and windows are open

|

 Only use OUTSIDE and far away from windows, doors, and vents

CUSTOMER SUPPORT

For customer support, scan the QR code

Questions? Call 855.944.3571 or
visit wpowereq.com/pages/support

Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Westinghouse User Manuals

Related Manuals