INSTALLATION

Removing fluorescent lamp system
NOTE: Westinghouse T8 LED is suitable to be installed in T8 standard luminaries.

  1. Disconnect power from luminaire.
  2. Remove fluorescent bulb.
  3. Remove wiring compartment cover.
  4. Cut all wires which are connected to the ballast and remove from luminaire.Westinghouse-W-735-Tube-Light-Bulb-1

Retrofitting fixtures with ONE LAMP

  1. Make sure AC power to luminaire is OFF

  2. Make sure ground wire from AC supply is securely connected to ground screw inside luminaire

  3. Connect black (live) lead wire to lamp holder on one end of luminaire and then connect white (neutral) lead wire to lamp holder on the opposite end of luminaire. If only one lamp is being installed, proceed to step 4.
    Retrofitting luminaire with MULTIPLE LAMPS
    After completing steps 1-3 above, connect black (live) and white (neutral) lead wires to remaining lamp holdersWestinghouse-W-735-Tube-Light-
Bulb-2

  4. When all connections are complete, place appropriate connectors/wire nuts on the end of any unused wires.

  5. Replace wiring compartment cover.

  6. Place sticker that is included with this product on wiring compartment cover or other conspicuous place on or inside of fixture. Sticker reads: “This fixture has been modified. The ballast has been removed. DO NOT install fluorescent lamps in this fixture”.

  7. Install LED tube(s).

  8. Re-connect power to luminaire.
    NOTE: This tube can operate with 0-10V dimming when installed in combination with dimming module (Westinghouse Lighting model 502606930). One dimming module only can work with one LED tube.

Wiring diagram:

Westinghouse-W-735-Tube-Light-
Bulb-3

WARNING
Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control. Only operate with specific dimmer 502606930 manufactured by Westinghouse.
Type B LAMP – intended for operation in luminaires with traditional fluorescent-type lamp holders wired directly to the branch circuit. This includes both factory-wired luminaries as well as those converted for this purpose under a retrofit program.
Warning: Risk of fire or electric shock. LED retrofit kit installation requires knowledge of luminaires electrical systems. IF not qualifed, do not attempt installation. Contact a qualified electrician.
Warning: Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

WARNING- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITES HAVE JURISDICTION.
The units covered by this report were intended to retrofit surface mount with diffuser for these models, Type IC or non-IC recessed mount listed fluorescent luminaires that use maximum 2 tubular lamps, the minimum lamp compartment dimensions are tabulated below:

MODEL NUMBER| MINIMUM COMPARTMENT DIMENSIONS [Length x Width x Height] [cm]/[in]| LAMP QUANTITY| Lamp-to-Lamp Spacing (cm)
---|---|---|---
LED 40T8/96”/DIM/XX Ballast Bypass| 244 x 27 x 7 / 96.06 x 10.63 x 2.76| 2| 11

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The luminaire wiring has now been modified and will no longer operate fluorescent lamps. Suitable for damp locations.
This device is not intended for use with emergency exits.