BEGA 85143 Powerful Floodlight Instruction Manual

July 18, 2024
BEGA

BEGA 85143 Powerful Floodlight

Specifications:

  • Model : Leistungsscheinwerfer Performance floodlight
  • Model Number : 85 143
  • Lamp Module Connected Wattage : 25.7 W
  • Luminaire Connected Wattage : 28.5 W
  • Rated Temperature: 25-35°C
  • Ambient Temperature : 25-35°C

Product Usage Instructions

Safety:

The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should perform the installation and commissioning to avoid damage from improper use or installation. Any modifications made to the luminaire should be done by a responsible person.

Overvoltage Protection:

The electronic components in the luminaire are protected against overvoltage according to standards. For additional protection against transients, separate overvoltage protection components are recommended and can be found on the manufacturer’s web ite.

Installation:

LED components are sensitive, avoid direct contact with the light output opening during installation or relamping. Place the floodlight unit onto the mounting plate, align it as per the provided sketch, and securely screw it together. Adjust the beam direction using a hexagon socket head wrench size 5 mm.

Adjusting the Half Beam Angle:

Follow the provided positions for adjusting the half-beam angle. Planning data for corresponding half-beam angles are available for download on the manufacturer’s website.

Additional Instructions:

Remove the adjustment aid from the housing and retain it. Place the trim ring with glass on the floodlight housing, twist it clockwise until it stops, and screw in the locking pin at the back of the housing using a hexagon socket wrench SW 2.5.

FAQ

  • Q: Can I install the luminaire myself?
    • A: No, the installation and commissioning should only be carried out by a qualified electrician to ensure safety and proper functionality.
  • Q: Where can I find additional protection components?
    • A: Additional protection components can be found on the manufacturer’s website at www.bega.com.

DIMENSIONS

Instructions for use

Application

Performance floodlight with focusable zoom optics.
Half beam angle adjustable between 15° and 52° by turning the optical lens unit. With mounting box for permanent installation on a wall, under a ceiling or on a base. For a variety of interior and exterior lighting applications.

Product Description

Luminaire made of aluminum alloy, aluminum and stainless steel
BEGA Unidure® coating technology
Color graphite or silver
Matt safety glass
Silicone gasket
Optical lens made of silicate glass
The rotation range of floodlight 350°
Swivel range -25°/+90°
Mounting box with 2 fixing holes ø 4.8mm · 67mm spacing
2 cable entries for through-wiring of mains supply cable ø 7-10.5mm, max. 5G1.5
Connecting terminal 2.5 with plug connection
Earth conductor connection
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V

DALI-controllable

Number of DALI addresses: 1

Basic insulation is provided between the mains and control cables

BEGA Thermal Control®

Temporary thermal regulation to protect

temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets Impact strength IK06 Protection against mechanical impacts < 1 joule
c – Conformity mark
Wind catching area : 0.023 m²
Weight: 2.3 kg
This product contains light sources of energy efficiency class(es) F

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at  www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.

Installation

LEDs are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo the hexagon socket head screw (wrench size 3mm) up to the stop and disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate. Note the position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.

Be sure to use the gasket rings supplied. Make an earth conductor connection. Push silicone sleeves over the lines and make an electrical connection to the terminal (plug connection).
For digital control please use the 2-pole plug connector DA, DA.

In case this connector is not used the luminaire will be operated at full light output. Push plug into the coupler as far as it will go. Connect the floodlight unit’s green and yellow protective earth conductor to the terminal marked 1 in the mounting plate. Make sure that the gasket is positioned correctly.

Place the floodlight unit onto the mounting plate as displayed in the sketch, and align and screw it together firmly.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
Tighten the joint screw.
Torque = 7Nm.

Adjusting the half beam angle

Loosen the locking pin (hexagon socket wrench SW2.5) on the back of the floodlight housing. Remove the trim ring along with the safety glass by twisting it anti-clockwise.

The half-beam angle can be adjusted between 15° and 52° by turning the optical lens unit. Turn clockwise to decrease the half beam angle; anti-clockwise to increase it.
The enclosed grey adjustment aid is used for simplified adjustment of the desired half-beam angle (pos. 1–5), especially for uniform adjustment of luminaires that are mounted in a line.
To do this, turn the optical lens unit counterclockwise as far as it will go.
Place the adjustment aid on the cylindrical pin as shown in the sketch and press it all the way down.
Turn the lens unit clockwise to the desired position (see table).

Planning data for the corresponding half-beam angles are available for download on our website

Remove the adjustment aid from the housing and retain.
Place the trim ring with glass on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other. Twist on the trim ring clockwise as far as the stop. Screw in the locking pin (hexagon socket wrench SW 2.5) on the back of the floodlight housing.

Lamp

  • Module connected wattage 25.7 W
  • Luminaire connected wattage 28.5 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=35 °C

85 143K3

  • Module designation LED-1145/930
  • Color temperature 3000 K
  • Color rendering index CRI >90
  • Module luminous flux 3140 lm
  • Luminaire luminous flux 2087 lm
  • Luminaire luminous efficiency 73,2 lm/W

85 143K4

  • Module designation LED-1145/940
  • Color temperature 4000 K
  • Color rendering index CRI >90
  • Module luminous flux 3300 lm
  • Luminaire luminous flux 2193 lm
  • Luminaire luminous efficiency 76,9 lm/W

Please note:

Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacing the LED module

The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system.

Open the floodlight: Undo the locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight
housing. Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise. Replace LED module. Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.

The defective glass must be replaced. Place trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top to each other. Twist on the trim ring clockwise as far as the stop. Tighten locking pin.

Accessories

71 290 Optical filter flat beam
71332 Shield
71 337 Cylindrical shield

For the accessories, separate instructions for use can be provided upon request.

Spares

Trim ring graphite with glass 25 000 279
Trim ring silver with glass 25 000 280
LED power supply unit DEV-0353/700
LED module 3000 K LED-1145/930
LED module 4000 K LED-1145/940
The lens unit 75 004 802
Gasket housing 83 000 521
Gasket mounting box 83 001 839
Gasket Abschlussring 83 002 222

BEGA Gantenbrink -euchten KG

Postfach 3160

58689 Mer
info@bega.com

www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals