BEGA 85137K3 Performance Floodlight Instruction Manual

July 18, 2024
BEGA

BEGA 85137K3 Performance Floodlight

BEGA-85137K3-Performance-Floodlight-Product

Product Information

Specifications

  • Material: Aluminum alloy, aluminum, stainless steel
  • Power Supply: LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V
  • Control: DALI-controllable, with 1 DALI address
  • Insulation: Basic insulation provided between hands
  • Safety: Safety class I, Protection class IP 65, Impact strength IK06
  • Light Sources: Energy efficiency class E

Product Usage Instructions

Facility

  1. Installation and commissioning should only be carried out by a qualified electrician.
  2. Ensure the luminaire is mounted securely using the provided mounting box with 2 fixing holes.
  3. Connect the earth conductor properly to ensure safety.

Operation

  1. Ensure the power supply is within the specified range (220-240 V x 0/50-60 Hz DC 176-280 V).
  2. Use the DALI control to adjust the lighting as needed.

Maintenance
Regularly check for any signs of damage or wear and tear. Contact a professional if repairs are needed.

FAQ

  • Q: What should I do if the luminaire is not working?
    A: Check the power supply, and connections, and ensure proper installation. If issues persist, contact a qualified electrician for assistance.

  • Q: Can I modify the luminaire myself?
    A: No, any modifications to the luminaire should be done by a professional to avoid damage or safety hazards.

Application

  • Performance floodlight with mounting box.
  • For a variety of interior and exterior lighting applications.

Product Description

  • Luminaire made of aluminum alloy, aluminum, and stainless steel
  • BEGA Unidure® coating technology
  • Color graphite or silver
  • Clear safety glass
  • Silicone gasket
  • The reflector surface is made of pure aluminum
  • BEGA Hybrid Optics®
  • The rotation range of floodlight is 350°
  • Swivel range -35°/+90°
  • Mounting box with 2 fixing holes ø 4.8 mm · 67 mm spacing 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5G 1.5@
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • Compline with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-280 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the hands and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical impacts < 1 joule
  • – Conformity mark
  • Wind catching area: 0.017 m²
  • Weight: 1.4 kg
  • This product contains light sources of energy efficiency class(es) E

Lighting technology

  • Symmetrical wide beam light distribution
  • Half beam angle 45°
  • For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Lamp

  • Module connected wattage 10.2 W
  • Luminaire connected wattage 11.6 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

85 137 K3

  • Module designation LED-1148/930
  • Color temperature 3000 K
  • Color rendering index CRI > 90
  • Module luminous flux 1500 lm
  • Luminaire luminous flux 1098 lm
  • Luminaire luminous efficiency 94,7 lm/W

85 137 K4

  • Module designation LED-1148/940
  • Color temperature 4000 K
  • Color rendering index CRI > 90
  • Module luminous flux 1575 lm
  • Luminaire luminous flux 1153 lm
  • Luminaire luminous efficiency 99,4 lm/W

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage under DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Installation

  • LEDs are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Undo the hexagon socket head screw (wrench size 3 mm) up to the stop and disassemble the mounting plate.
  • Pass the power connecting cable through the cable entry in the mounting plate.
  • Note the position of application of the mounting plate “arrow down”.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied.
  • Make an earth conductor connection.
  • Push silicone sleeves over the lines and make an electrical connection to the terminal (plug connection).
  • For digital control please use the 2-pole plug connector DA, DA.
  • In case this connector is not used the luminaire will be operated at full light output.
  • Push the plug into the coupler as far as it will go.
  • Connect the floodlight unit’s green and yellow protective earth conductor to the terminal marked in the mounting plate.
  • Make sure that the gasket is positioned correctly.BEGA-85137K3-Performance-Floodlight-Fig- \(2\)
  • Place the floodlight unit onto the mounting plate as displayed in the sketch, and align and screw together firmly.

Adjustment of beam direction:

  • Undo the joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
  • Tighten the joint screw.
  • Torque = 7 Nm.

Dimension

BEGA-85137K3-Performance-Floodlight-Fig- \(1\)

Cleaning and maintenance

  • Clean the fixture regularly with solvent-free cleaners from dirt and deposits.
  • Do not use high-pressure cleaners.

Maintenance
The connecting cable between the mounting box and floodlight has to be inspected for obvious damages and has to be replaced by a qualified electrician only.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system from the power supply.

Open the floodlight:

  • Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
  • Replace the LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
  • Twist on the trim ring clockwise as far as the stop.

Accessories

  • 71 289 Optical filter flat beam
  • 71 331 Shield
  • 71 336 Cylindrical shield

For the accessories, separate instructions for use can be provided upon request.

Spare Parts

  • Trim ring graphite with glass 25 000 273
  • Trim ring silver with glass 25 000 274
  • LED power supply unit DEV-0515/300i
  • LED module 3000 K LED-1148/930
  • LED module 4000 K LED-1148/940
  • Reflector 75 005 131
  • Gasket housing 83 000 486
  • Gasket mounting box 83 001 839
  • Gasket trim ring 83 002 169

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com .

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals