Performance floodlight
Instructions for use
Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to
ISO 228 supplied by others or to BEGA accessories.
For a variety of interior and exterior lighting applications.
Product description
Luminaire made of aluminum alloy, aluminum and stainless steel BEGA Undue®
coating technology Color graphite or silver Clear safety glass Silicone gasket
Reflector surface made of pure aluminum BEGA Hybrid Optics® Rotation range of
floodlight 350° Swivel range -30°/+100° Mounting bracket with G½ threaded
connection
Thread length: 14mm Connecting cable X05BQ-F 5G1mm² Cable length 1m BEGA
Ultimate Driver® Complies with flicker requirements in accordance with IEEE
1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit 220-240 V x
0/50-60 Hz DC 176-264 V DALI-controllable
Number of DALI addresses: 1 Basic insulation is provided between the
mains and control cables BEGA Thermal Control® Temporary thermal regulation to
protect temperature-sensitive components without switching off the luminaire
Safety class I Protection class IP 65 Dust-tight and protection against water
jets Impact strength IK06 Protection against mechanical impacts < 1 joule –
Conformity mark
Wind catching area: 0.021 m² This product contains light sources of
energy efficiency class(as) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40Nm.
Secure the screw connection from loosening on site (if provided with locking
screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27
mm) and set the desired beam direction (see sketch B, C). Torque:
Hexagon socket screw = 7 Nm Hexagon nut = 35 Nm Secure bolted connection Gß
against loosening by tightening the hexagon socket screws (wrench size 2 mm).
The electrical connection must be carried outwith matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable. The earth conductor is
connected at the green-yellow (1), the phase to the brown (L), and the neutral
conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads
marked with DALI. In case these leads are not used the luminaire will be
operated at full light output.
Lamp
Module connected wattage 24.1 W Luminaire connected wattage 26.8 W Rated
temperature ta=25 °C Ambient temperature ta max=40 °C
85 160K3
Module designation LED-0800/930 Colour temperature 3000 K Colour rendering
index CRI >90 Module luminous flux 3350 lm Luminaire luminous flux 2472 lm
Luminaire luminous efficiency 92,2 lm/W
85 160K4
Module designation LED-0800/940 Colour temperature 4000 K Colour rendering
index CRI >90 Module luminous flux 3400 lm Luminaire luminous flux 2509 lm
Luminaire luminous efficiency 93,6 lm/W
Lighting technology
Symmetrical wide beam light distribution Half beam angle 45° For special
lighting applications, an optical filter can be used to change the symmetrical
light cone into a flat beam light distribution.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be
replaced by a qualified electrician.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light color and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of
the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it
counterclockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a
way that the notches in the trim ring and floodlight housing align on top to
each other.
Twist on the trim ring clockwise as far as the stop. Tighten locking pin.
Accessories
71 290: Optical filter flat beam
71332: Shield
71 337: Cylindrical shield
70 214: Pole cap for pole ø 48 mm
70 248: Pole cap for pole ø 60 mm
70 245: Mounting box
70 252: General fastener
70 280: Tube clamp G½
70 283: Screw clamp
70 379: Cross beam G½
70 889: Tension belt
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass: 25 000 277
Trim ring silver with glass: 25 000 278
LED power supply unit: DEV-0353/700
LED module: 3000 K LED-0800/930
LED module: 4000 K LED-0800/940
Reflector: 75 005 075
Gasket housing: 83 000 521
Gasket trim ring: 83 001 952
References